  temperature indication process indication over-temperature protection process value trip unit 2108 i model indicator and alarm unit eurotherm ontrols universal input covers a wide range of temperature and process inputs two alarm relay outputs for operator alert and plant protection wide-range 85-264v ac, can be installed world-wide supply plug-in from front rapid replacement - reducing downtime front panel configuration easy, on-site set-up tactile buttons friendly operation three year warranty low ownership cost ideal for: features: model 2108 i 1/8 din (96 x 48mm) the 2108 i provides accurate measurement and display of temperature and other process variables in a standard 1/8 din panel format. two alarm relay outputs are provided for operator alert and process protection. a universal input allows selection of nine internally stored thermocouple types. other input linearisations may be factory downloaded. linear, process inputs are scaleable to the desired display range. keylock and passwords prevent unauthorised access to configuration and alarm settings. a large, red or green led display gives good visibility in low and high ambient lighting. new alarms can be acknowledged and old alarms reset by a front panel button or an external contact closure input. three internal alarm setpoints are provided. they are configurable as high, or low, or rate of change alarms. any combination of the three internal alarms can activate the two relay outputs. latching or non-latching operation can be selected and alarm delays can be applied. a special mode known as alarm blocking is available. in this mode, after power on, the process value must first enter a good state before the alarm becomes active. this is particularly useful for low alarms which can be blocked while the process is warming-up. calibration accuracy is preserved with a self-correcting input circuit, while a user calibration facility allows offsets to be applied to compensate for sensor and other system errors. indicator and alarm unit
op2 op1 2108 i ack/ reset e u r o t h e r m e part no. ha026159 issue 3 electrical connections specifications display: 4 digit, red or green. 15.9mm high characters supply voltage: 100 to 240vac -15%, +10% operating ambients: 0-55?, 5-95%rh non-condensing panel sealing: ip54, plug-in from front panel relay ratings: 2a, 240vac resistive calibration accuracy: ?.25% of reading, or ??, or ?lsd whichever is the greater cold junction compensation: >15 to 1 rejection of ambient temperature change input filtering: off-999.9 seconds emc standards: en50081-2 and en50082-2 generic standards for industrial environments safety standard: meets en61010, installation category ii. pollution degree 2 atmospheres: not suitable for use above 2000m or in explosive or corrosive atmospheres panel cut-out 45 x 92 mm - 0.0 + 0.6 48 mm (1.89in) dimensions - 0.0 + 0.8 alarm acknowledge/reset sensor inputs 85-264vac lc la lb n l relay output 1 v- v+ vi ac ab aa ground line neutral model 2108 i relay output 2 3c 3b 3a link for keylock t/c pt100 ma input 2.49 96 mm (3.78in) 103 mm (4.01in) 1.77 x 3.62 in - 0 + 0.03 -0 + 0.02 ?copyright eurotherm controls limited 1998 all rights strictly reserved. no part of this document may be stored in a retrieval system, or any form or by any means without prior written permission from eurotherm controls limited. every effort has been taken to ensure the accuracy of this specification. however in order to maintain our technological lead we are continuously imp roving our products which could, without notice, result in amendments or omissions to this specification. we cannot accept responsibility for damage, injury, loss or expenses resulting therefrom. eurotherm controls limited http://www.eurotherm.co.uk uk sales office eurotherm controls limited. faraday close, durrington, worthing, west sussex bn13 3pl telephone sales: (01903) 695888; technical: (01903) 695777; service: (01903) 695444 fax (01903) 695666 sales and support in over 30 countries worldwide enquiries/orders to: eurotherm controls limited export dept., faraday close, durrington, worthing. west sussex bn13 3pl. telephone (01903) 268500 fax (01903) 265982 vh 85-264vac display colour gn green rd red relay output 1 function al alarm unit sensor input setpoint min/max units c ? f ? k kelvin x linear input ordering code input adaptor xx not fitted v1 0-10vdc a1 0-20ma current sense resistor (2.49 0.1%) supply voltage 2108 i al vh model number function supply voltage relay output 1 relay output 2 manual sensor input note 1 setpoint min. note 1 setpoint max. units input adaptor rf unconfigured non-latched alarm fh high alarm 1 fl low alarm 1 al high alarm 1 & low alarm 3 ra rate of change alarm 1 latched alarm ha high alarm 1 la low alarm 1 aa high alarm 1 & low alarm 3 rt rate of change alarm 1 nw new alarm status standard sensor inputs min ? max j j thermocouple -210 to 1200 k k thermocouple -200 to 1372 t t thermocouple -200 to 400 l l thermocouple -200 to 900 n n thermocouple-nicrosil/nisil -200 to 1300 r r thermocouple-pt/pt13%rh -50 to 1768 s s thermocouple-pt/pt10%rh -50 to 1768 b b thermocouple-pt/pt30%rh-6%rh 0 to 1820 p platinell ii thermocouple 0 to 1369 z rtd / pt100 din 43760 -200 to 850 factory downloaded input min ? max c c thermocouple - w5%re/w26%re(hoskins) 0 to 2319 d d thermocouple - w3%re/w25%re 0 to 2399 e e thermocouple -200 to 1000 1 ni/ni18%mo thermocouple 0 to 1399 2 pt20%rh/pt40%rh thermocouple 0 to 1870 3 w/w26%re (engelhard) thermocouple 0 to 2000 4 w/w26%re (hoskins) thermocouple 0 to 2010 5 w5%re/w26%re (engelhard) thermocouple 10 to 2300 6 w5%re/w26%re (bucose) thermocouple 0 to 2000 7 pt10%rh/pt40%rh thermocouple 200 to 1800 8 exergen k80 i.r. pyrometer -45 to 650 process inputs (scaled to setpoint min and max) min max m -9.99 to +80mv linear -1999 to 9999 y 0 to 20ma linear (note 2) -1999 to 9999 a 4 to 20ma linear (note 2) -1999 to 9999 v 0 to 10vdc linear (input adapter required) -1999 to 9999 note 1. setpoint min and max: include the decimal points required in the display value; up to one for temperature inputs, up to two for process inputs. note 2. a 1% 2.49 current sense resistor is supplied as standard. if greater accuracy is required a 0.1% resistor can be specified in the input adaptor field. relay output 2 display colour rf unconfigured non-latched alarm fh high alarm 2 fl low alarm 2 ra rate of change alarm 2 latched alarm ha high alarm 2 la low alarm 2 rt rate of change alarm 2 nw new alarm status manual xx no manual eng english fra french ger german ned dutch spa spanish swe swedish ita italian


▲Up To Search▲   

 
Price & Availability of 2108I

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X