  rev. 03.30.10_29 lps100-m series 1 of 3 embedded power for business-critical continuity lps100-m series 150 watts special features ? medical and ite safeties ? active power factor correction ? 2 x 4 footprint ? less than 1u high ? en61000-3-2 compliant ? remote sense ? power fail ? adjustable main output ? built-in class b emi filter ? overvoltage protection ? overload protection ? thermal overload protection ? isolated12 v fan output ? lpx50 enclosure kit available total power: 80 - 150 watts input voltage: 90 - 264 vac # of outputs: single electrical specifications safety input input ra nge: 90 - 264 vac; 120 - 300 vdc frequency: 47-63 hz inrush current: 50 a max., cold start @ 25 c efficiency: 88% typical at full load emi/rfi: fcc class b conducted; cispr22 class b conducted; en55022 class b conducted; vde0878pt3 class b conducted safety ground leakage current: 275 a @ 50/60 hz, 264 vac input output maximum power: 100 w for convection (80 w for LPS102-M); 150 w with 30 cfm forced air (120 w for LPS102-M) adjustment range: 10% minimum on the main outputs fan output: 12 v @ 1 a isolated, 10% hold-up time: 10 ms @ 150 w load, 120 vac input overload protection: short circuit protection on all outputs. case overload protected @ 110-160% above rating overvoltage protec tion: 15-35% above nominal output logical control power failure: open collector logic signal goes high 100-500 msec after main output; it goes low at least 6 msec before loss of regulation remote sense: compensates for 0.5 v lead drop min. will operate without remote sense connected. reverse connection protected. ? tuv 60950, 60601-1 ? ul 60950, 60601-1 ? culus 60950, 60601-1 ? cb certificate & report ? ce mark (lvd) ? cqc mark
embedded power for business-critical continuity mechanical drawing rev. 03.30.10_29 lps100-m series 2 of 3 operating temperature: 0 to 50 c ambient derate each output as 2.5% per degree from 50 to 70 c. -20 c start up storage temperature: -40 c to +85 c electromagnetic susceptibility: designed to meet en61000-4; -2, -3, -4, -5, -6, -8, -11 level 3 humidity: operating; non-condensing 10% to 95% rh vibration: iec68-2-6 to the levels of iec721-3-2 mtbf calculated: 534,000 hours at full load and 25 c ambient conditions, 230 v input, bellcore environmental specifications sk1 sk2 sk203 2.00" (50.8) 4.00" (101.6) 1.72" (43.8) 1.29" (33.0) 3.73" (94.7) mounting hole ?0.16"[4.0] 4 places max. screw head diameter .22 (5.6) m1 m2 gnd vr1 output v oltage a djust pot sk5 1 3 4 1 8 1 4 1 0.10 (2.5) 0.197 (5.0) minimum standoff heigh t
rev. 03.30.10_29 lps100-m series 3 of 3 embedded power for business-critical continuity ordering information model number output voltage minimum load maximum load with convection cooling maximum load with 30cfm forced air peak load regulation 2 ripple p/p (pard) 3 LPS102-M 5 v 0 a 16 a 24 a 30 a 2% 50 mv lps103-m 12 v 0 a 8.3 a 12.5 a 14 a 2% 120 mv lps104-m 15 v 0 a 6.7 a 10 a 11 a 2% 150 mv lps105-m 24 v 0 a 4.2 a 6.3 a 7 a 2% 240 mv lps108-m 48 v 0 a 2.1 a 3.1 a 3.5 a 2% 480 mv 1. peak current lasting < 30 seconds with a maximum 10% duty cycle. 2 . at 25 c including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3 . peak-to-peak with 20 mhz bandwidth and 10 f (tantalum capacitor) in parallel with a 0.1 f capacitor at rated line voltage and load ranges. notes: 1. specifications subject to change without notice. 2. all dimensions in inches (mm), tolerance is .02. 3. mounting holes mh1, mh2 should be grounded for emi purpose 4. mounting mh1 is safety ground connection 5. specifications are for convection rating at factory settings at 115 vac input 25 c unless otherwise stated. 6. this power supply requires mounting on metal standoffs 0.20 (5 m) in height. 7. for dc input an external dc safety rated fuse must be used. 8. warranty: 2 year 9. weight: 0.44 lb. / 0.20 kg americas 5810 van allen way carlsbad, ca 92008 usa telephone: +1 760 930 4600 facsimile: +1 760 930 0698 europe (uk) waterfront business park merry hill, dudley west midlands, dy5 1lx united kingdom telephone: +44 (0) 1384 842 211 facsimile: +44 (0) 1384 843 355 asia (hk) 14/f, lu plaza 2 wing yip street kwun tong, kowloon hong kong telephone: +852 2176 3333 facsimile: +852 2176 3888 for global contact, visit: www.emerson.com/embeddedpower techsupport.embeddedpower @emerson.com while every precaution has been taken to ensure accuracy and completeness in this literature, emerson network power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. emerson network power and the emerson network power logo are trademarks and service marks of emerson electric co. ?2010 emerson electric co. emersonnetworkpower.com embedded computing embedded power monitoring outside plant power switching & controls precision cooling racks & integrated cabinets services surge protection emerson network power. the global leader in enabling business-critical continuity. ac power connectivity dc power pin assignments connector lps100-m sk1 pin 1 neutral pin 3 line sk2 pin 1 common pin 2 common pin 3 common pin 4 common pin 5 +vout pin 6 +vout pin 7 +vout pin 8 +vout sk203 pin 1 common pin 2 power fail pin 3 - remote sense pin 4 + remote sense sk5 pin 1 +12 v fan pin 2 +12 v fan pin 3 fan return (isolated) pin 4 fan return (isolated) mating connectors ac input (sk1): molex p/n: 09-50-3031, pins: 08-52-0072 or landwin p/n: 3060s0302, pins: 3360t011p ac ground molex: 01-90020001 dc output (sk2): molex p/n: 09-50-3081, pins: 08-52-0072 or landwin p/n: 3060s0802, pins: 3360t011p remote sense (sk203): molex p/n: 35155-0400, pins: 08-70-0057 or landwin p/n: 2640s04a0, pins: 2543t011p fan: (sk5): molex p/n: 22-01-1042, pins: 08-70-0049 or landwin: p/n: 2510s04a0, pins: 2543t011p emerson network power connector kit #70-841-025, includes all of the above


▲Up To Search▲   

 
Price & Availability of LPS102-M

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X