Part Number Hot Search : 
1N753A 16NO7 R2500 121621BF 38000 STR91XF SG200 STM8403
Product Description
Full Text Search
 

To Download DTB-R232 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  www.boser.com.tw 4-extrude &top #6-32 b b bb b b a a a a 4-extrude &top #6-32 d d d d 0.8 7.0 3.3 0.5 7.2 0.7 0.11 6.0 1.3 0.5 3.16 8.68 0.61 7.38 2.65 0.63 1.3 6.0 0.55 industrial power supply redundant redundant DTB-R232 230w redundant power supply safety standards features *input voltage: 90~130vac or 180~260vac *input frequency: 47~63hz *inrush current: does not exceed 30a at 115vac input or 60a ac input, at cold start 25 o c *load range: when all outputs are in 60% rated load condition, the +5v output is set between 4.98~5.02v while all other outputs are within the specified voltage accuracy range *ripple and noise: peak to peak ripple and noise for +5v, output is < 50mv, and < 100mv for +12v, -12v, -5v outputs at rated load, 115/230vac *line regulation: < +/-1% for each output at rated load and +/-10% of 115vac or 230vac input voltage change *load regulation: the output voltage load regulation is less than the value on the table when subjected to +/-40% change on each output load from 60% rated load, and while all other outputs are at 60% rated load *hold up time: > 16ms at 115vac input and rated load measured from the last ac line charging pulse to the point when +5v drops to +4.75v *output power: the total dc continuous power is whthin 230w at < 30 o c ambient temperature *power good signal: when turned on, the signal goes high 100~500ms after all output dc voltages are within regulation limits *power redundancy: this power supply has power redundant capability *efficiency: > 70% at rated load *altitude: 10,000 feet *protection: built-in over voltage protection circuit shuts down the outputs to prevent damage. trip point of crowbar circuit is between 5.7~7v; latch off mode against short circuit or over load conditions ac line on/off cycle recovers unit from fault conditions *temperature: 0~+40 o c (operating); -40~+75 o c (storage) *humidity: 5~95%; non-condensing at 40 o c (operating) *connectors: ac: one ac input socket dc: o1 din 41612 c96 *dimensions: 14.0 x 15.0 x 8.62 cm +/-5mm tolerance *mtbf: 235,743 hrs. *safety: ul 1950 / csa 22.2 no.234 / vde en60950 *emi: fcc class b / en55022b *ems: level 3 of iec-801, 802, 803, 804 output voltage +5v +12v -12v min. load 1a 0.1a 0a rated load 20a 10a 0.5a max. load 25a 12a 1a tolerance +/-0.1v +/-0.72v +/-0.6v -5v 0a 0.5a 1a +/-0.25v


▲Up To Search▲   

 
Price & Availability of DTB-R232

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X