2007-03-27 1 bgx50a... silicon switching diode array ? bridge configuration ? high-speed switching diode chip ? pb-free (rohs compliant) package 1) ? qualified according aec q101 bgx50a type package configuration marking bgx50a sot143 bridge u1s maximum ratings at t a = 25c, unless otherwise specified parameter symbol value unit diode reverse voltage v r 50 v peak reverse voltage v rm 70 forward current i f 140 ma non-repetitive peak surge forward current i fsm - total power dissipation t s 74c p tot 210 mw junction temperature t j 150 c storage temperature t stg -65 ... 150 thermal resistance parameter symbol value unit junction - soldering point 2) bgx50a r thjs 360 k/w 1 pb-containing package may be available upon special request 2 for calculation of r thja please refer to application note thermal resistance
2007-03-27 2 bgx50a... electrical characteristics at t a = 25c, unless otherwise specified parameter symbol values unit min. typ. max. dc characteristics breakdown voltage v (br) - - - reverse current v r = 50 v v r = 50 v, t a = 150 c i r - - - - 0.2 100 a forward voltage i f = 100 ma v f - - 1.3 v ac characteristics diode capacitance v r = 0 v, f = 1 mhz c t - - 1.5 pf reverse recovery time i f = 10 ma, i r = 10 ma, measured at i r = 1ma , r l = 100 ? t rr - - 6 ns test circuit for reverse recovery time ehn00019 f d.u.t. oscillograph pulse generator: t p = 100ns, d = 0.05, t r = 0.6ns, r i = 50 ? oscillograph: r = 50 ? , t r = 0.35ns, c 1pf
2007-03-27 3 bgx50a... reverse current i r = ? ( t a ) v r = parameter bgx 50a ehb00146 25v 70v max. typ. 5 10 10 1 2 5 10 10 5 r 3 4 10 na 5 0 50 100 t a ?c 150 v r = 70 v forward voltage v f = ? ( t a ) i f = parameter 0 0.5 1.0 0 50 100 150 bgx 50a ehb00149 v t a v f ?c f = 100 ma 10 ma 1 ma 0.1 ma forward current i f = ? ( v f ) t a = 25c 0 0 ehb00147 bgx 50a 0.5 1.0 v 1.5 50 100 ma 150 f f v max typ peak forward current i fm = ? ( t p ) t a = 25c 10 ehb00148 bgx 50a -6 -1 10 5 t d = t p t t p t d = 5 10 0 a 10 1 2 10 10 -5 10 -4 10 -3 10 -2 10 0 s 0.005 0.01 0.02 0.05 0.1 0.2 fm
2007-03-27 4 bgx50a... forward current i f = ? ( t s ) bgx50a 0 15 30 45 60 75 90 105 120 c 150 t s 0 20 40 60 80 100 120 ma 160 i f
2007-03-27 5 bgx50a... package sot143 package outline foot print marking layout (example) standard packing reel ?180 mm = 3.000 pieces/reel reel ?330 mm = 10.000 pieces/reel rf s 2005, june date code (ym) bfp181 type code 56 pin 1 0.8 0.8 1.2 0.9 1.1 0.9 1.2 0.8 0.8 0.8 -0.05 +0.1 1.9 1.7 0.1 2.9 +0.1 -0.05 0.4 0.1 max. 12 3 4 0.25 m b 0.1 1 10? max. 0.15 min. 0.2 a m 2.4 0.15 0.2 10? max. a 1.3 0.1 0...8? 0.08...0.15 2.6 4 3.15 pin 1 8 0.2 1.15 b manufacturer
2007-03-27 6 bgx50a... edition 2006-02-01 published by infineon technologies ag 81726 mnchen, germany ? infineon technologies ag 2007. all rights reserved. attention please! the information given in this dokument shall in no event be regarded as a guarantee of conditions or characteristics (?beschaffenheitsgarantie?). with respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, infineon technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights of any third party. information for further information on technology, delivery terms and conditions and prices please contact your nearest infineon technologies office ( www.infineon.com ). warnings due to technical requirements components may contain dangerous substances. for information on the types in question please contact your nearest infineon technologies office. infineon technologies components may only be used in life-support devices or systems with the express written approval of infineon technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. if they fail, it is reasonable to assume that the health of the user or other persons may be endangered.
|