  general specifications electrical specifications sensorless vector variable frequency inverters - 0.4kw to 4.0kw n high performance torque vector control n over 200% torque at 1 hz n footprint filters for emc compliance n user friendly auto tuning n ultra compact ip40 enclosure n fast torque response n low motor noise profile n user programmable i/o n integral detachable keypad n single and three phase versions n rs485 communications port (optional) n renowned imo 5 year warranty jaguar vxs compact single and three phase torque vector systems for small three phase motors single phase input three phase input 23 45 56 81 129 42 51 67 97 120 weight (kg) 1.1 1.6 1.7 2.7 2.8 1.8 1.8 2.7 2.7 3.2 enclosure rating ip40 cooling method fan assisted ambient temperature -10 to +50?c (remove covers >+40?c) relative humidity 20 to 95% non condensing vibration 5.9 m/s 2 (0.6g) max altitude 1000 metres max heat loss at minimum carrier frequency (w) natural convection fan assisted natural convection jaguar vxs order codes vxs20-1 vxs40-1 vxs75-1 VXS150-1 vxs220-1 vxs40-3 vxs75-3 vxs150-3 vxs220-3 vxs400-3 motor rating (kw) 0.2 0.75 1.5 2.2 0.75 1.5 2.2 4.0 maximum rated 1.5 3.0 5.0 8.0 11.0 1.6 2.5 3.7 5.5 9.0 100% rated i/p current a rms 2.95 4.1 7.2 14.0 20.0 1.3 2.2 4.3 6.0 9.8 input voltage 200 - 240 ac, 10%, 1 phase 380 - 480 ac, + 10 to -15%, 3 phase input frequency 50 - 60 hz, 5% output voltage ac, 0 - v input pwm output frequency 0.2 - 400 hz 0.37 0.55 0.37 0.55 o/p current (a) 5
connection diagram jaguar vxs f c l1 fl2 (l) fl3 (n) c 1 1 3 1 2 1 1 p24 fwd rev bx rst x1 x2 x3 x4 cm thr u v w m gnd(p e ) p 1 (+) d b 30a 30b 30c fmp fma yie cmc (+) (C) pulse link external brake resistor (optional) dc reactor (optional) power terminals symbol terminal name description l1, l2, l3 for connecting 3 phase power supply (vxs - 3 only) l, n for connecting single phase power supply (vxs - 1 only) u, v, w for 3 phase ac induction motor p1, (+) (+), db connection for brake resistor to increase braking torque gnd (pe) earth terminal safety electrical earth main input power terminals main input power terminals power output terminals dc reactor terminals external brake resistor terminals optional dc reactor terminals for improving power factor (fitted with shorting link) note: under no circumstances should the above guide be considered sufficient for the attainment of relevant emc emission limits. please consult the product manual for full information regarding compliance. common for yie programmable output to terminal 11 warning! this equipment must be earthed caution: do not short circuit. terminal p24 to terminal 11, cm or cme digital frequency meter to cm terminal analog frequency meter (10 v/1 ma dc) * from p24 terminal from thr terminal alarm output (any fault) (relay shown in power on or off and healthy state) note: figures in brackets are for single phase models frequency reference current input (4~20 ma dc) manual frequency setting potentiometer (10k /1w) +24v forward operation and stop command reverse operation and stop command coast - to - stop command alarm reset multistep frequency select function extension input external alarm input 240v 1? or 415v 3? 50/60 hz * gnd(pe) panel control prg mode run hz a v r/min m/min prg reset run func data stop
control circuit terminals jaguar vxs purpose terminal terminal name description 11 speed reference for use with terminals 12, 13, c1 and fma 0v common 12 reference input 0 - 10v dc input, impedance = 22 k 13 potentiometer supply +10v dc power supply for 1 k speed control potentiometer. output 10ma max. c1 current loop input 4 - 20ma input, impedance = 250 fwd forward and stop fwd - p24 closed C motor runs forward command open C motor stops rev reverse and stop rev - p24 closed C motor runs in reverse command open C motor stops bx coast - to - stop bx - p24 closed C output inhibited instantaneously command open C normal thr rst trip/alarm reset if rst - p24 is closed for 3 100ms following a trip condition, the inverter will reset x1, x2, x3 preset speeds combinations of x1, x2, x3 - p24 will call for preset frequencies to be output x4 function depending upon the setting of function no. 43 extension terminal acts as C acc 2 / dec 2 pattern select C extension to 15 preset speeds C 2nd motor v/f profile C fwd/rev latch for 3-wire i/p p24 +24v dc supply internal 24v dc supply for control inputs cm common terminal common terminal for fmp and digital inputs fma analogue output output frequency, current, torque or load factor can be selected, 0 - 10v dc, 1ma maximum up to 2 metres of cable is recommended for connection to this terminal fmp digital output output proportional to frequency of motor 6 khz maximum, fully scalable yie programmable selectable for:- output 1) inverter running 2) frequency level detected 3) frequency hysteresis band reached 4) undervoltage trip 5) torque limiting 6) auto restart maximum 27v dc, 50 ma cmc common terminal used for yie output only 30a normally 30b - 30c closed with power off or on, with drive 30b fault relay output healthy 30c 30a - 30c closes on fault. rated 250v, 0.3a analog frequency setting control inputs meter outputs control outputs if both fwd and rev are opened or closed, then the inverter output stops external trip or enable/disable data edit mode ? thr - p24 closed C normal open C trips output instantaneously or ? thr - p24 closed C normal open C data protected
dimensions (mm) jaguar vxs vxs40-1 and vxs75-1 (single phase) vxs40-3 and vxs75-3 (three phase) panel control prg mode run hz a v r/min m/min prg reset run func data stop * centrelines of 3 cable entry holes, 22mm dia. 30 30 128 140 5 6 5 6 6 138 150 2 holes , 5mm 45 5 109 75 *** * removable side-cover panel control prg mode run hz a v r/min m/min prg reset run func data stop 30 30 188 200 5 6 5 6 6 138 150 71 5 100 134 VXS150-1 and vxs220-1 (single phase) vxs150-3 and vxs220-3 (three phase) * centrelines of 3 cable entry holes, 22mm dia. *** * 2 holes , 5mm removable side-cover vxs400-3 (three phase) panel control prg mode run hz a v r/min m/min prg reset run func data stop 30 30 188 200 5 6 5 6 6 138 150 86 5 115 149 * centrelines of 3 cable entry holes, 22mm dia. *** * 2 holes , 5mm removable side-cover panel control prg mode run hz a v r/min m/min prg reset run func data stop 65 85 12.3 7.9 67.5 remote mountable keypad with optional cable


▲Up To Search▲   

 
Price & Availability of VXS150-1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X