![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
fky 3 fky 5 fky 6 data sheet fky ... 4 small flange level transmitter specifications features the fcx? 2 small flange level transmitter accurately mea- sures liquid level and transmits a proportional 4 to 20ma signal. the transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microproces- sor technology to provide exceptional performance and func- tionality. 1. directly connectable to 1- 1 /2 in. and 2 in. flanges the transmitter is connectable to 1- 1 /2 in. and 2 in. pipes without a reducer. 2. minimum environmental influence the ?dvanced floating cell?design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 3. fuji/hart bilingual communications protocol and foundation fieldbus and profibus compatibil- ity fcx? 2 series transmitter offers bilingual communica- tions to speak both fuji proprietary protocol and hart . any hart compatible devices can communicate with fcx a 2 . further, by upgrading electronics foundation fieldbus and profibus are also available. 4. application flexibility various options that render the fcx? 2 suitable for almost any process applications include: analog indicator at either the electronics side or ter- minal side full range of hazardous area approvals built-in rfi filter and lightning arrester 5-digit lcd meter with engineering unit stainless steel electronics housing wide selection of materials high temperature, high vacuum service. 5. programmable output linearization function output signal can be freely programmable. (up to 14 compensated points at approximation.) 6. burnout current flexibility (under scale: 3.2 to 3.8ma, over scale: 20.8 to 21.6ma) burnout signal level is adjustable using model fxw hand held communicator (hhc) to comply with namur ne43. 7. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry cali- bration without reference pressure is at equal level as wet calibration. remark: to minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. lower limit of static pressure (vacuum limit) ; silicone fill sensor: see fig.1 fluorinated fill sensor: 66kpa abs (500mmhg abs) at temperature below 60 c. the maximum span of each sensor can be converted to different units using factors as below. 1mpa=10 3 kpa=10bar=10.19716kgf/cm 2 =145.0377psi 1kpa=10mbar=101.9716mmh 2 o=4.01463inh 2 o overrange limit: to maximum static pressure limit output signal: 4 to 20ma dc with digital signal superim- posed on the 4 to 20ma signal power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with op- tional arrester. functional specifications service: liquid, gas, or vapour static pressure, span, and range limit: range limit [kpa] {m bar} type span limit [kpa] {m bar} +/?32 { +/?320} +/?130 { +/?1300} +/?500 { +/?5000} max. 32 {320} 130 {1300} 500 {5000} 3 {30} 13 {130} 50 {500} min. static pressure up to flange rating ? ? ? date EDSX7-62K apr. 1, 2007
fky ... 4 2 2000 [ ? ] 1500 1000 load resistance 500 250 0 1533 ? 600 ? operating area 24v 45v 10 16.1 50 [ v ] 10.5v power voltage load limitations: see figure below note: for communication with hhc (1) (model: fxw), min. of 250 ? required. hazardous locations: (note) (1) hhc: hand held communicator a tex ex ii 2 gd eex d iic t6 ip66/67 t85 c tamb = -40 c to +65 c eex d iic t5 ip66/67 t100 c tamb = -40 c to +85 c factory mutual class i div.1 groups b, c, d t6 type 4x class ii iii div.1 groups e, f, g t6 type 4x tamb max = +60 c authorities flameproof iecex scheme /saa ex d iic t5 ip66/67 pending tamb = -40 c to +85 c ex d iic t6 ip66/67 pending tamb = -40 c to +65 c tiis ex do iib+h 2 t4 tamb max = +55 c maximum process temp.=+120 c csa - a tex ex ii 1 gd eex ia iic t5 tamb = -40 c to +40 c eex ia iic t4 tamb = -40 c to +80 c entity parameters: ui=28v, ii=93.3ma, pi=0.66w, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.134mh factory mutual class i ii iii div.1 groups a, b, c, d, e, f, g t4 entity type 4x entity parameters: vmax=42.4v, imax=113ma, pi=1w, ci=34.2nf, li=1.134mh authorities intrinsic safety iecex scheme /saa ex ia iic t4 ip66/67 tamb = -40 c to +70 c ex ia iic t5 ip66/67 tamb = -40 c to +50 c entity parameter: ui=28v, ii=93.3ma, pi=0.66w, ci=0.033 f, li=1.034mh tiis ex ia iic t4 tamb max = +60 c entity parameter: ui=28v, ii=94.3ma, pi=0.66w, ci=32.6nf, li=1.134mh csa class i div.1 groups a, b, c, d class ii div.1 groups e, f, g class iii div.1 t emp code t4 tamb max = +40 c t emp code t3c tamb max = +85 c entity parameters: vmax=28v, imax=93ma, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.4mh model code 9th digit 13th digit t amb a,b,d y, g , h,s -40 c to +85 c l,p,1,2 y, g , h,s -20 c to +80 c q,s,4,5 y, g , h,s -20 c to +60 c e,f,h y, g , h,s -40 c to +60 c - w,a,d -10 c to +60 c 3 ?utput underscale? adjustable within the range 3.2ma to 3.8ma from hhc (1) 3.8 3.2 4 20 20.8 21.6 [ma] over scale burnout probable over range probable under range normal operating range under scale burnout loop-check output: transmitter can be configured to provide constant signal 3.8ma through 21.6ma by hhc (1) . temperature limit: ambient: ?15 to + 65 c (?15 to + 65 c for lcd indicator) (?15 to + 60 c for arrester option) (?10 to + 60 c for fluorinated oil fill transmitter) (?10 to + 60 c for silicon oil ?? ?? for explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits speci- fied in each standard. process: zero/span adjustment : zero and span are adjustable from the hhc (1) . zero and span are also adjustable externally from the adjustment screw (span adjustment is not available with 9th digit code ?, p, q , s?. damping: adjustable from hhc or local adjustment unit with lcd display. the time constant is adjustable between 0.12 to 32 seconds. zero elevation/suppression: ?100% to + 100% of url normal/reverse action: selectable from hhc (1) indication: analog indicator or 5-digit lcd meter, as specified. burnout direction: selectable from hhc (1) if self-diagnostic detect transmitter fail- ure, the analog signal will be driven to ei- ther ?utput hold? ?utput overscale or ?utput underscale?modes. ?utput hold? output signal is hold as the value just be- fore failure happens. ?utput overscale? adjustable within the range 20.8ma to 21.6ma from hhc (1) programmable output linearization function: output signal can be characterized with ?4 points linear approximation function from hhc (1) . emc conformity: en61326 13th digit of ?ode symbols fill fluid lower limit of static press w, a and d h y and g s fluorinated oil silicone oil atmospheric pressure 2.7kpa abs {20.3mmhg abs} 20 to 80 c 0to 250 c ?0 to 120 c 0to 250 c process temperature low pressure side contact liquid temperature on transmitter of code h, s, is 120 c or lower. storage: ?40 to + 70 c humidity limit: 0 to 100% rh communication: with hhc (1) (model fxw, consult data sheet no. eds8-47), following informa- tion can be remotely displayed or recon- figured. note: hhc? version must be more than 6.0 (or fxw 1 3), for fcx- a 2 . tag no. model no. serial no. engineering unit range limit measuring range damping output mode burnout direction calibration output adjust data self diagnoses printer external switch lock transmitter display linearize rerange vv vv v vv v vv vv v vv vv ? v v vv vv vv vv items display set a tex ex ii 3 gd eex nl iic t5 tamb = -40 c to +40 c eex nl iic t4 tamb = -40 c to +80 c specific parameters: model without arrester: ui=42.4v, ii=113ma, pi=1w, ci=27nf, li=1.134mh model with arrester: ui=32v, ii=113ma, pi=1w, ci=34.2nf, li=1.134mh eex nal iic t5 tamb = -40 c to +40 c eex nal iic t4 tamb = -40 c to +80 c specific parameters: model without arrester: umax=42.4v, imax=113ma, pmax=1w, model with arrester: umax=32v, imax=113ma, pmax=1w factory mutual class i ii iii div.2 groups a, b, c, d, f, g t4 entity type 4x authorities t ype n nonincendive iecex scheme /saa - tiis - csa class i div.2 groups a, b, c, d class ii div.2 groups e, f, g class iii div.2 t emp code t4 tamb max = +40 c t emp code t3c tamb max = +85 c entity parameters: vmax=28v, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.4mh model code 9th digit 13th digit tamb a,b,d y, g , h,s -40 c to +85 c l,p,1,2 y, g , h,s -20 c to +80 c q,s,4,5 y, g , h,s -20 c to +60 c e,f,h y, g , h,s -40 c to +60 c - w,a,d -10 c to +60 c fky ... 4 4 performance specifications reference conditions, silicone oil fill, 316ss isolating diaphragms, 4-20 ma analog output in linear mode. accuracy rating: (including linearity, hysteresis, and re- peatability) (standard) for spans greater than 1 /10 of url: 0.25% of span for spans below 1 /10 of url: 0.17 + 0.08 % of span (option) (code: 21th digit h, k) for spans greater than 1 /10 of url: 0.1% of span for span below 1 /10 of url: 0.05 + 0.05 % of span stability: 0.2% of upper range limit (url) for 3 years. temperature effect: effects per 28 c change between the lim- its of ?15 c and + 65 c zero shift; 0.5%/28 c ( x equal to 1 /2 url or more) zero shift; 0.5 url %/28 c 2 x ( x less than 1 /2 url) total shift; 0.75%/28 c ( x equal to 1 /2 url or more) total shift; 0.25 +0.5 url %/28 c 2 x ( x less than 1 /2 url) 0.1 x url span () static pressure effect: zero shift: 0.2% of url/1mpa overrange effect: zero shift; 0.1% of url for flange rat- ing pressure supply voltage effect: less than 0.005% of calibrated span per 1v rfi effect: less than 0.2% of url for the frequen- cies of 20 to 1000mhz and field strength 30 v/m when electronics covers on. (classification: 2-abc: 0.2% span per sama pmc 33.1) update period: 120 msec * ) step response: (without electrical damping) () () (option) (code: 21th digit j, k) zero shift; 0.5%/28 c ( x equal to 1 /6.5 url or more) zero shift; 0.5 url %/28 c 6.5 x ( x less than 1 /6.5 url) total shift; 0.75%/28 c ( x equal to 1 /6.5 url or more) total shift; 0.25 +0.5 url %/28 c 6.5 x ( x less than 1 /6.5 url) where, x : calibrated span url : maximum span (upper range limit) 0.1 x url span () time constant *) 0.3 s dead time *) 0.2 s process cover 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) hastelloy-c monel lining tantalum diaphragm 316l stainless 316l stainless 316l stainless 316l stainless 316l stainless hastelloy-c monel tantalum hastelloy-c monel tantalum material code (7th digit in ?ode symbols? v j c d e h m t b l u lp side note: (* 1 ) scs14a per jis g 5121 (equivalent cf8m per astm a351/a351m) remark: sensor o-rings: viton o-ring or teflon gasket selectable wetted sensor body 316 stainless 316 stainless 316 stainless 316 stainless 316 stainless hastelloy-c lining monel lining tantalum lining hastelloy-c lining monel lining tantalum lining hp side diaphragm & flange face 316l stainless 316l stainless steel + au coating hastelloy-c monel tantalum hastelloy-c monel tantalum hastelloy-c monel hastelloy-c mounting position effect: zero shift, less than 0.3kpa{3m bar} for a 10 tilt in any plane. (no extension) no effect on span. this error can be corrected by adjusting zero. dielectric strength: 500v ac, 50/60hz 1 min., between cir- cuit and earth. insulation resistance: more than 100m ? at 500v dc. turn-on time: 4 sec internal resistance for external field indicator: 12 ? or less physical specifications electrical connections: g 1 /2 , 1 /2 -14 npt, pg13.5, or m20 x 1.5 conduit, as specified. and 1-conduit or 2-conduit, as specified. process connections: lp side: 1 /4 -18 npt or rc 1 /4 . hp side: ansi, or jis raised face flange. see outline diagram for detailed di- mensions. refer to ?ode symbols process-wetted parts material: non-wetted parts material: electronics housing: low copper die-cast aluminum alloy finished with epoxy/ polyurethane double coating(standard), or 316 stainless steel (scs14a per jis g5121), as specified. bolts and nuts: cr-mo alloy (standard) or 304 stainless steel fill fluid: silicone oil (standard) or fluori- nated oil mounting flange: 304 stainless steel or carbon steel, as specified. environmental protection: iec ip67 and nema 6 / 6p flange mounting: see drawings * ) faster response is available as option (maxi- mum update rate : 25 times per second) () () 5 the product conforms to the requirements of the electromagnetic compatibility directive 94/9/ec as detailed within the technical construction file number tn513035. the applicable standards used to demonstrate compliance are : frequency range mhz limits reference standard 30 to 230 40db ( v/m) quasi peak, measured at 10m distance 230 to 1000 47db ( v/m) quasi peak, measured at 10m distance cispr16-1 and cispr16-2 phenomenon test value basic standard performance criteria b electrostatic discharge conducted rf 0.15 to 80mhz 3v 80%am (1khz) electromagnetic field 4kv (contact) 8kv (air) 80 to 1000mhz 10v/m 80%am (1khz) en61000-4-2 burst a en61000-4-3 rated power frequency magnetic field 30a/m 50hz a en61000-4-8 2kv 5khz b en61000-4-4 surge 1.2 s/50 s 1kv (line to line) 2kv (line to ground) b en61000-4-5 a en61000-4-6 emi (emission) en61326 : 1997 class a (standard for industrial location) emi (immunity) en61326: 1997 annex a (standard for industrial location) note) definition of performance criteria a: during testing, normal performance within the specification limits. b: during testing, temporary degradation, or loss of function or performance which is self-recovering. accessories oval flanges: (model ffp, refer to data sheet no. eds6-10) converts process connection to 1 /2 -14 npt or to rc 1 /2 ; in carbon steel or in 316 stainless steel. hand held communicator: (model fxw, refer to data sheet no. eds 8-47) z/s board: parts no.=zzpfcx4-a070 when z/s board is mounted on the fcxe a 2 amplifier unit, external adjustment screw will be available for zero and span adjustment. operating area non-operating area 101 {1010} 53.3 {533} 13.3 {133} 2.7 {27} [kpa abs] {m bar abs} operating pressure e40 0 60 85 120 200 230 250 process temperature silicone (code y,g) filled liquid: [ fky ... 4 6 diaphragm & flange face 316 stainless steel diaphragm: 316l stainless steel +au coating flange face: 316 stainless steel hastelloy-c monel tantalum hastelloy-c monel tantalum hastelloy-c monel tantalum 0 1 2 3 4 5 a b c d g h j k l m q r s t 3 5 6 v j c d e h m t b l u a b c d e s t v w x hp side lp side description digit 4 5 6 7 7 a b c d x r g h k p t v y b c e m n p q y a b c d description note digit 9 10 11 12 fky ... 4 8 y w g a d h s a b c d a b e (11th digit code "y" only) (13th digit code "h", "s" are not available.) description note digit 13 14 15 21 9 ordering information when ordering this instrument, specify: 1. code symbols 2. measuring range 3. output orientation (burnout direction) when abnormality is occurred in the transmitter. hold / overscale (21.6ma) / underscale (3.2ma). unless otherwise specified, output hold function is supplied. 4. indication method (indicated value and unit) in case of the actual scale (code d, h, p, s on 9th digit). 5. tag no. (up to 26 alphanumerical characters), if required. fky ... 4 10 outline diagram (unit:mm) < 7th digit code : "v", "j", "c" , "d", "e", "h", "m"or "t" > sensor unit electronics unit "a" l. p. conn. in case of frange with 4 bolt holes 8 2.5 m k 17 l.p. conn. h.p. conn + + ck+ + ck ? ?5 ?3 hj g1/2 ?8.5 inner of gasket zero adj. screw vent / drain plug (when the vent / drain plug attatched on the upper side of the detector) "b" conduit conn. vent / drain plug long vent/drain p lug (option) with field ind. cable gland (option) "c" conduit conn. fastener (flameproof only) oval flange screw see table 1 detail "a" detail "b" detail "c" connection diagram 2 l 20 41.3 t 88 ?8 ?9 ?4 27 48 43 143 ? ? 52.5 94.5 105 8 ?0 (27) ?0 43.5 n holes h dia. earth terminal in case of 4th digit code "t" in case of 4th digit code "a.b.c.d.e" in case of 4th digit code "s.v.w.x" up down 105 10 5th digit of code symbols 11th digit of code symbols l [mm] 1 23 mass approx, [kg] ? ? 0, g 140 105 36 4-19 jis-10k-40a y 0 333 160 296 9.5 to 12 a 50 10 to 17 b 100 327 154 290 10.5 to 17.5 c 150 11 to 18 d 200 11.5 to 18.5 1, h 155 120 36 4-19 jis-10k-50a 2, j 140 105 39 4-19 jis-20k-40a 3, k 155 120 38 8-19 jis-20k-50a 4, l 160 120 42 4-23 jis-30k-40a 5, m 165 130 42 8-19 jis-30k-50a a, q 127 98.4 37.5 4-16 ansi/jpi-150lb-1 1/2b b, r 152 120.6 39.5 4-20 ansi/jpi-150-2b c, s 156 114.3 41 4-23 ansi/jpi-300lb-1 1/2b d, t 165 127 42.5 8-20 ansi/jpi-300lb-2b tn- h flange table 1 jkm h g1/2 17 8 rc1/4 7/16-20unf screw depth15 a, s 1/2-14npt 18 5 1/4-18npt 7/16-20unf screw depth15 b, t pg13.5 84 .5 1/4-18npt m10 screw depth15 c, v 16 5 1/4-18npt m10 screw depth15 d, w pg13.5 84 .5 1/4-18npt 7/16-20unf screw depth15 e, x 4th digit of the code symbols conduit conn. press. conn. oval flange screw note) cable gland is supplied in case offlamproof packing type. ?1 cable is suitable. note) 1 3 m20 15 11 sensor unit electronics unit note) ?2 ?6 ?5 j ?3 g1/2 ?6 ? 1/4-18npt 0.2 0.2 +0.1 +0.1 0 0 0.1 0.1 h.p. conn 1 10 km 17 2 details of "a" 4th of code symbols "a, s" type details of "b" 4th of code symbols "b, c, d, e, t, v, w, x" type + + ck+ ck in case of flange with 4 bolt holes "a" or "b" l. p. conn. oval flange screw see table 1 zero adj. screw n holes h dia. fastener (flameproof only) cable gland (option) "d" conduit conn. with field ind. "c" conduit conn. 1 vent / drain plug inner of gasket details of "c" details of "d" connection diagram earth terminal 41.3 150 323 88 52.5 94.5 105 8 ?0 ?0 (27) 20 t 107 286 ?9 ?4 40.5 91 43 186 ? ? in case of 4th digit code "t" in case of 4th digit code "a.b.c.d.e" in case of 4th digit code "s.v.w.x" up down 105 10 4th digit of the code symbols conduit conn. oval flange screw 5th digit of code symbols ? see table 1 ? 0, g 140 105 36 4-19 jis-10k-40a 1, h 155 120 36 4-19 jis-10k-50a 2, j 140 105 39 4-19 jis-20k-40a 3, k 155 120 38 8-19 jis-20k-50a 4, l 160 120 42 4-23 jis-30k-40a 5, m 165 130 42 8-19 jis-30k-50a a, q 127 98.4 37.5 4-16 ansi/jpi-150lb-1 1/2b b, r 152 120.6 39.5 4-20 ansi/jpi-150-2b c, s 158 114.3 41 4-23 ansi/jpi-300lb-1 1/2b d, t 165 127 42.5 8-20 ansi/jpi-300lb-2b t n-? flange jkm g1/2 17 8 7/16-20unf screw depth10 a, s 1/2-14npt 16 5 7/16-20unf screw depth10 b, t pg13.5 8 4.5 m10 screw depth10 c, v 16 5 m10 screw depth10 d, w pg13.5 8 4.5 7/16-20unf screw depth10 e, x note) cable gland is supplied in case of flamproof packing type. ?1 cable is suitable. m20 15 table 1 < 7th digit code : "b", "l" or "u" > fky ... 4 information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fesys.co.jp/eng instrumentation div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance. |
Price & Availability of EDSX7-62K
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |