  specifications are subject to change without notice (06.11.00) 1 monitoring relays product description ordering key housing function type item number output power supply ? 3-phase over and under voltage, phase sequence, phase loss and asymmetry monitoring relay ? detect when all 3 phases are present and have the correct sequence ? detect if all the 3-phase-phase or phase-neutral voltages are within the set limits ? detect if asymmetry is below set value ? separately adjustable setpoints ? separately adjustable delay functions (0.1 to 30 s) ? output: 2 x 8 a relay spdt ne or nd (selectable) ? for mounting on din-rail in accordance with din/en 50 022 (dpc01) or plug-in module (ppc01) ? 45 mm euronorm housing (dpc01) or 36 mm plug-in module (ppc01) ? led indication for relay, alarm and power supply on type selection mounting output supply: 208 to 240 vac supply: 380 to 480 vac din-rail 2 x spdt dpc 01 d m23 dpc 01 d m48 plug-in 2 x spdt ppc 01 d m23 ppc 01 d m48 input l1, l2, l3, n dpc01: terminals l1, l2, l3, n ppc01: terminals 5, 6, 7, 11 measure on own supply measuring ranges 208 to 240 vac 177 to 275 vac 380 to 480 vac (DPC01DM48) 323 to 550 vac 380 to 415 vac (ppc01dm48) 323 to 475 vac ranges upper level +2 to +22% of the nominal voltage lower level -22 to -2% of the nominal voltage asymmetry 2 to 22% of the nominal voltage tolerance 2 to 22% of the nominal voltage 3-phase, 3-phase+n, multi-function types dpc01, ppc01 input specifications output 2 x spdt relays rated insulation voltage 250 vac contact ratings (agsno 2 ) resistive loads ac 1 8 a @ 250 vac dc 12 5 a @ 24 vdc small inductive loads ac 15 2.5 a @ 250 vac dc 13 2.5 a @ 24 vdc mechanical life 3 30 x 10 6 operations electrical life 3 10 5 operations (at 8 a, 250 v, cos j = 1) operating frequency 7200 operations/h dielectric strength dielectric voltage 2 kvac (rms) rated impulse withstand volt. 4 kv (1.2/50 s) output specifications dpc 01 d m48 3-phase or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry, over and under voltage (separately adjustable set points) with built-in time delay function. supply ranges from 208 to 480 vac covered by two multivoltage relays. dpc01 ppc01
2 specifications are subject to change without notice (06.11.00) dpc01, ppc01 mode of operation connected to the 3 phases (and neutral) dpc01 and ppc01 operate when all 3 phases are present at the same time and the phase sequence is correct. it can be decided whether to moni- tor upper and lower voltage level of each phase or their asymmetry and tolerance. in any case if phase-netural measurement is selected both phase-phase and phase-neutral voltages are monitored. asymmetry is defined as fol- lows: when measuring phase- phase voltages and also as follows: when measuring phase-neu- tral voltages. tolerance is defined as and also as when measuring phase-neu- tral voltages. voltage level monitoring: if one or more phase-phase or phase-neutral voltage exceeds the upper set level or drops below the lower set level, the red led starts flashing 2 hz and the respective output relay releases after the set time period. asymmetry and tolerance monitoring: if one of them exceeds the set level the red led starts flashing 2 hz and the respective output relay releases after the set time period. if the phase sequence is wrong or one phase is lost, both output relays release immediately. only 200 ms delay occurs. the failure is indicated by the red led flashing 5 hz during the alarm condition. example 1 (mains - over and under phase-phase voltage - moni- toring) the relay monitors over and under voltage, phase loss and correct phase sequence. example 2 (starting and operating load - asymmetry and tolerance phase-neutral - monitoring) dpc01 and ppc01 ensure correct starting and operat- ing conditions. they monitor the voltage level, phase sequence (correct direction of the motor rotation) and asymmetry. frequent failures are fuse blowing and incorrect volt- age level. in case of fuse blowing the motor regener- ates a voltage in the inter- rupted phase. these relays detect the failure and react due to excessive imbalance among the phases. power supply overvoltage cat. iii rated operational voltage (iec 60664, iec 60038) through terminals: l1, l2, l3, n (dpc01) 5, 6, 7, 11 (ppc01) m23: 208 to 240 vac 15% 45 to 65 hz m48: 380 to 480 vac 15% 45 to 65 hz rated operational power m48 13 va @ 400 vac, 50 hz m23 13 va @ 230 vac, 50 hz supplied by l2 and l3 supply specifications indication for power supply on led, green alarm on led, red (flashing 2 hz during delay time) output relay on 2 x led, yellow environment (en 60529) degree of protection ip 20 pollution degree 3 (dpc01), 2 (ppc01) operating temperature -20 to 60c, r.h. < 95% @ 475 vac, 65 hz -20 to 50c, r.h. < 95% @ 550 vac, 65 hz storage temperature -30 to 80c, r.h. < 95% housing dimensions din-rail version 45 x 80 x 99.5 mm plug-in version 36 x 80 x 87 mm weight approx. 220 g screw terminals tightening torque max. 0.5 nm acc. to iec 60947 ce-marking ye s general specifications (cont.) max{| ? v ph-ph |} nom. voltage max{| ? v ph-n |} nom. voltage max{|nom. voltage - ? v ph-ph |} nom. voltage max{|nom. voltage - ? v ph-n |} nom. voltage power on delay 1 s 0.5 s or 6 s 0.5 s reaction time incorrect phase sequence or total phase loss < 200 ms voltage level (input signal variation from -20% to +20% or from +20% to -20% of set value) asymmetry level alarm on delay < 200 ms (delay < 0.1 s) alarm off delay < 200 ms (delay < 0.1 s) accuracy (15 min warm-up time) temperature drift 1000 ppm/c delay on alarm 10% on set value 50 ms repeatability 0.5% on full-scale general specifications
specifications are subject to change without notice (06.11.00) 3 example 1 l2 l3 l1 l1 l2 l3 l2 l3 m<3 u n n 25 26 28 15 16 18 example 2 l2 l3 l1 l1 l2 l3 l2 l3 m<3 u 25 26 28 15 16 18 n n example 1 67 5 l1 l2 l3 l2 l3 m<3 u n 11 10 89 1 43 example 2 67 5 l1 l2 l3 l2 l3 m<3 u 10 89 1 43 n 11 ? wiring diagrams dpc01 ppc01 dpc01, ppc01 l1 l2 l3 relay (1) on relay (2) on red led on l1 l2 l1 l2 l1 l3 l2 l3 l3 1 or 6 s operation diagrams selection of function: dip-switch selector (1 to 6) 1 power on delay 6 0.5 s power on delay 1 0.5 s 2 phase-neutral voltage phase-phase voltage 34 3 x 208 ? vac (m23) 3 x 380 ? vac (m48) 3 x 220 ? vac (m23) 3 x 400 ? vac (m48) 3 x 230 ? vac (m23) 3 x 415 ? vac (m48) 3 x 240 ? vac (m23) 3 x 480 ? vac (DPC01DM48) 5 2 x spdt relays 1 x dpdt relay 6 asymmetry + tolerance overvoltage + undervoltage selection of level and time delay: centre knobs: setting of upper and lower level or setting of asymmetry and absolute tolerance of set value on relative scale. lower knobs: setting of delay on alarm time on absolute scale (0.1 to 30 s). function/range/level and time delay setting on
4 specifications are subject to change without notice (06.11.00) upper level hysteresis hysteresis lower level relay 1(upper) on (15/16/18) relay 2 (lower) on (25/26/28) red led on l1 or l1-l2 l2 or l2-l3 1 or 6 s 1 or 6 s 1 or 6 s l3 or l1-l3 t t t red led on asymmetry (+) hysteresis balanced asymmetry (-) tolerance (+) nominal voltage hysteresis hysteresis tolerance (-) l1 or l1-l2 l2 or l2-l3 l3 or l1-l3 relay 1 asymmetry (15/16/18) on 1 or 6 s t t t 1 or 6 s 1 or 6 s t t relay 2 tolerance (25/26/28) on l2-l1 or v l2-l1 -v l3-l2 l3-l2 or v l3-l2 -v l1-l3 l1-l3 or v l1-l3 -v l2-l1 hysteresis operation diagrams (cont.) dpc01, ppc01


▲Up To Search▲   

 
Price & Availability of DPC01DM48

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X