  Datasheet File OCR Text:
  universal ac input / full rangebuilt-in active pfc function high efficiency up to 90% withstand 300vac surge input for 5 seconds protections: short circuit / overload / over voltage protections: over temperature (optional) cooling by free air convection 1u low profile 38mm medical safety approved (moop level) built-in remote on-off control no load power consumption<0.5w (note.6) all using 105 long life electrolytic capacitors 5 years warranty ?e?e ?e ?e ?e ?e ?e ?e ?e ?e ?e ?e ?e j specification MSP-100-3.3 MSP-100-5 MSP-100-7.5 MSP-100-12 MSP-100-15 MSP-100-24 MSP-100-36 MSP-100-48 model dc voltage rated current current range rated power ripple & noise (max.) note.2 output voltage adj. range voltage tolerance note.3 line regulation load regulation setup, rise time hold up time (typ.) voltage range note.5 frequency range power factor (typ.) efficiency (typ.) input environment inrush current (typ.) leakage current note.7 over temperature safety standards safety & emc (note 4) withstand voltage isolation resistance working temp. remote control working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage protection ac current (typ.) 3.3v 5v 7.5v 12v 15v 24v 36v 48v 20a 17a 13.5a 8.5a 7a 4.5a 2.9a 2.2a 0 ~ 20a 0 ~ 17a 0 ~ 13.5a 0 ~ 8.5a 0 ~ 7a 0 ~ 4.5a 0 ~ 2.9a 0 ~ 2.2a 66w 85w 101.3w 102w 105w 108w 104.4w 105.6w 80mvp-p 80mvp-p 100mvp-p 120mvp-p 150mvp-p 150mvp-p 200mv p-p 240mvp-p 3.1 ~ 3.8v 4.75 ~ 5.8v 7.1 ~ 9v 11.4 ~ 13.8v 14.25 ~ 18v 22.8 ~ 28.8v 34.2 ~ 39.6v 45. 6 ~ 55.2v ? 0.5% ? 0.5% ? 0.5% ? 0.3% ? 0.3% ? 0.2% ? 0.2% ? 0.2% ? 2.0% ? 2.0% ? 1.5% ? 0.8% ? 0.8% ? 0.5% ? 0.5% ? 0.5% 2500ms, 100ms/230vac 2500ms, 100ms/115vac at full load 50ms/230vac 20ms/115vac at full load 85 ~ 264vac 120 ~ 370vdc 47 ~ 63hz pf>0.95/230vac pf>0.98/115vac at full load 78% 83% 6 ~ 7v 9.4 ~ 10.9v 14.4 ~ 16.8v 18.8 ~ 21.8v 30 ~ 34.8v 41.4 ~ 48.6v 57.6 ~ 67.2v 84% 87.5% 88% 88.5% 89% 90% 1.2a/115vac 0.6a/230vac 35a/115vac 65a/230vac 105 ~ 135% rated output power protection type : constant current limiting for vo=50 ~ 100% of rated volta ge, recovers automatically after fault condition is removed 3.96 ~ 4.62v protection type : shut down o/p voltage, re-power on to recover protection type : o/p voltage, recovers automatically after temper ature goes down shut down i/p-o/p:4kvac i/p-fg:2kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh j -40 ~ +60 j (refer to "derating curve") rc+/rc- : 0 ~ 0.8v= power on ; 4 ~ 10v = power off 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh j ? j j) 0.04%/ (0 ~ 50 10 ~ 500hz, 5g 10min./1cycle, 60min. each along x, y, z axes 295.7k hrs min. mil-hdbk-217f (25 ) j 159*97*38mm (l*w*h) file name:MSP-100-spec 2012-08-24 ?? features : 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. for guidance on how to perform these emc tests, please refe r to ?emi testing of component power supplies.? (as available on http://www.meanwell.com) 5. derating may be needed under low input voltages. please check the derati ng curve for more details. 6. no load power consumption<0.5w when rc+ & rc- (cn100 pin1,2) 0 ~ 8v or short. 7. touch current was measured from primary input to dc output. 8. when the input voltage is less than 40vac, the sps may exhibit degradation o f performance. the final product manufacturers must re-confirm this deviation that does not affect basic safety or essential performance. j m s p - 1 0 0 s e r i e s 100w single output medical type function 0.38kg; 24pcs/10.1kg/0.76cuft +2.5,-3.5% +2.5,-3.5% ? 2.5% ? 1.5% ? 1.5% ? 1.5% ? 1.5% ? 1.5% 90 (3.3v ~ 7.5v) , 85 (12v ~ 48v) (tsw1 : detect on heatsink q101 of power transist or)(optional) j j emc immunity emc emission ansi/aami es60601-1, iec60601-1 approved compliance to en55011 (cispr11) class b, en61000-3-2,-3 compliance to en61000-4-2,3,4,5,6,8,11, en60601-1-2 earth leakage current < 300 a/264vac , touch leakage current < 100 a/264 vac g g
mechanical specification case no.901i unit:mm terminal pin no. assignment pin no. pin no. 12 4,5 3 6,7 assignment assignment dc output -v dc output +v fg ac/l ac/n 4.5 9 152.5 7 150 6.5 18.5 78 97 84.5 65 3.5 24 159 22 117 9 28.5 r 3.5 r 3.5 18 3.5 38 6-m3(both sides) l=6 2-m 3 l=4 detection circuit svr1 10 max. 12 3 4 5 6 7 9.5 8.2 cn100 ii remote on/off (cn100) : jst b-xh or equivalent pin no. 12 assignment rc+ rc- mating housing jst xhp jst sxh-001t or equivalent or equivalent terminal 1 2 20 40 60 80 100 100w single output medical type file name:MSP-100-spec 2012-08-24 derating curve output derating vs input voltage ambient temperature ( ) j input voltage (v) 60hz 85 100 125 135 155 264 100 90 80 70 60 50 40 load (%) load(%) -40 0 10 20 30 40 50 60 70 (horizontal) o.l.p. o.t.p. emi inrush active filter current limiting rectifiers & pfc i/p fg pwm pfc power switching filter & rectifiers +v control control o.v.p. remote control -v rc+ rc- m s p - 1 0 0 s e r i e s block diagram


▲Up To Search▲   

 
Price & Availability of MSP-100

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X