Part Number Hot Search : 
RF3181 AD7928 AD679BJ AD679BJ CXA2202M LT1033CT NBSG16M L639210
Product Description
Full Text Search
 

To Download TP-7503 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  specification tp-75a tp-75b tp-75c model dc voltage rated current current range rated power output voltage adj. range line regulation load regulation setup, rise time hold up time (typ.) voltage range note.5 frequency range power factor (typ.) efficiency (typ.) input inrush current (typ.) leakage current safety standards harmonic current ems immunity working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage ac current (typ.) 5v ch1 12v ch2 -5v ch3 5v ch1 12v ch2 -12v ch3 5v ch1 15v ch2 -15v ch3 7a 3a 0.6a 7a 3a 0.4a 6a 2.5a 0.5a 1.5 ~ 10a 0.2 ~ 4a 0 ~ 0.6a 1.5 ~ 10a 0.2 ~ 4a 0 ~ 0.6a 1.5 ~ 10a 0.2 ~ 3a 0 ~ 0.6a 74w 75.8w 75w 100mvp-p 120mvp-p 100mvp-p 100mvp-p 120mvp-p 120mvp-p 100 mvp-p 120mvp-p 120mvp-p 3.0% 3.0% 3.0% 3.0% 3.0% 3.0% ch1: 4.75 ~ 5.5v 4.0% 4.0% 4.0% 4.0% 4.0% 4.0% 8.0% 8.0% 8.0% 8.0% 8.0% 8.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 800ms, 60ms at full load 36ms at full load 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz pf>0.95/230vac pf>0.98/115vac at full load 70% 1.5a/115vac 0.8a/115vac cold start 20a/230vac <2ma / 240vac 105 ~ 150% rated output power 5.75 ~ 6.75v on +5v protection type : hiccup mode, recovers automatically after fault con dition is removed protection type : shut down o/p voltage, re-power on to recover ul60950-1, tuv en60950-1 approved compliance to en55022 (cispr22) class b compliance to en61000-3-2,-3 compliance to en61000-4-2,3,4,5,6,8,11; env50204, en55024, li ght industry level, criteria a -10 ~ +60 (refer to output load derating curve) 20 ~ 90% rh non-condensing -20 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 50 10 ~ 500hz, 2g 10min./1cycle, 60min. each along x, y, z axes 198.4k hrs min. mil-hdbk-217f (25 ) 179*99*33mm (l*w*h) 0.65kg; 20pcs/12.7kg/0.64cuft 75w triple output with pfc function universal ac input / full range built-in active pfc function, pf>0.95 protections: short circuit / overload / over voltage low profile: 33mm thickness led indicator for power on cooling by free air convection fixed switching frequency at pfc:67khz pwm:134khz 3 years warranty features : t p - 7 5 s e r i e s ripple & noise (max.) note.2 voltage tolerance note.3 withstand voltage isolation resistance i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac 1min. i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh environment safety & emc (note 4) protection emi conduction & radiation 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 5. derating may be needed under low input voltages. please check the derati ng curve for more details. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) output number file name:tp-75-spec 2010-10-18
specification tp-75d TP-7503 model dc voltage rated current current range rated power output voltage adj. range line regulation load regulation setup, rise time hold up time (typ.) voltage range note.5 frequency range power factor efficiency (typ.) input inrush current (max.) leakage current safety standards harmonic current ems immunity working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage ac current 5v ch1 ch1 24v ch2 ch2 12v ch3 ch3 5v 3.3v 12v 7a 1.5a 0.4a 9a 8a 0.3a 1.5 ~ 10a 0.2 ~ 2.5a 0 ~ 0.6a 1.5 ~ 10a 0.2 ~ 8a 0 ~ 0.6a 75.8w 75w 100mvp-p 120mvp-p 120mvp-p 100mvp-p 50mvp-p 120mvp-p 3.0% 3.0% 3.0% 3.0% ch1: 4.75 ~ 5.5v 4.0% 4.0% 4.0% 4.0% 8.0% 8.0% 8.0% 8.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 800ms, 60ms at full load 36ms at full load 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz pf>0.95/230vac pf>0.98/115vac at full load 70% 1.5a/115vac 0.8a/115vac cold start 20a/230vac <2ma / 240vac 105 ~ 150% rated output power 5.75 ~ 6.75v on +5v protection type : hiccup mode, recovers automatically after fault con dition is removed protection type : shut down o/p voltage, re-power on to recover ul60950-1, tuv en60950-1 approved compliance to en55022 (cispr22) class b compliance to en61000-3-2,-3 compliance to en61000-4-2,3,4,5,6,8,11; env50204, en55024, li ght industry level, criteria a -10 ~ +60 (refer to output load derating curve) 20 ~ 90% rh non-condensing -20 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 50 10 ~ 500hz, 2g 10min./1cycle, 60min. each along x, y, z axes 198.4k hrs min. mil-hdbk-217f (25 ) 179*99*33mm (l*w*h) file name:tp-75-spec 2010-10-18 75w triple output with pfc function universal ac input / full range built-in active pfc function, pf>0.95 protections: short circuit / overload/ over voltage low profile: 33mm thickness led indicator for power on cooling by free air convection fixed switching frequency at pfc:67khz pwm:134khz 3 years warranty features : t p - 7 5 s e r i e s ripple & noise (max.) note.2 voltage tolerance note.3 withstand voltage isolation resistance i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac 1min. i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh environment safety & emc (note 4) protection emi conduction & radiation 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 5. derating may be needed under low input voltages. please check the derati ng curve for more details. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) 0.65kg; 20pcs/12.7kg/0.64cuft output number
mechanical specification derating curve output derating vs input voltage file name:tp-75-spec 2010-10-18 case no. 920a unit:mm ambient temperature ( ) input voltage (vac) 60hz 85 100 115 125 155 230 264 load (%) load (%) ta=25 10 20 30 40 50 60 70 20 40 60 80 100 -10 0 (horizontal) 90 100 80 70 60 50 40 with 18cfm forced air (15cm) convection t p - 7 5 s e r i e s 75w triple output with pfc function block diagram pfc fosc : 67khz pwm fosc : 134khz pwm & pfc circuit detection o.l.p. emi filter rectifiers circuit power switching filter & rectifiers +v -v i/p fg control o.v.p. & pfc constant current limiting & terminal pin no. assignment pin no. pin no. 7 68 assignment assignment ac/n dc output +v2 ac/l com dc output +v1 dc output +v3 fg 1 2,3 45 +adj. led 6.15 7.62 48 67 55 23 1 16 15 119 179 117 25 33 6-m4 l=6mm 32.5 17 18 8 60 65 2-m4 l=4mm 49.5 99 9 max.


▲Up To Search▲   

 
Price & Availability of TP-7503

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X