Part Number Hot Search : 
E2310 SPLC563A AD9768 STB520N D562KB NMR101C GL128P11 NMR102C
Product Description
Full Text Search
 

To Download HGN-369-2M Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  specifications subject to change without notice. dimensions (mm). see appendix a for recommended power cord. see pdi full line catalog for detailed specifications on power cords. iec 60320 inlet socket with voltage select, flange mount hgn-369 mechanical dimensions features the hgn-369 power entry modules are used in applications having the on/off switch on front side but main input at the rear side. this series features an iec connector, voltage selector for four different voltages (100v, 120v, 220v, 240v), fuse holder for european 5 x 20mm or n. american 1/4? x 1 1/4? (3ag) fuse. the filter is enclosed in a metal housing to ensure maximum protection from common-mode and differential-mode interferences. these filters are also available for medical equipment with low leakage current to comply with ul 544 & ul2601. applications computer & networking equipment, measuring & control equipment, data processing equipment, laboratory instruments, switching power supplies, other electronic equipment. technical data ? rated voltage: 125/250vac ? rated current: 1a, 2a, 3a, 4a, 6a, ? power line frequency: 50/60hz ? max. leakage current each line to ground: @ 250vac 50hz: 0.5ma, max @ 250vac 50hz: 2 a*, max ? hipot rating (one minute) line to ground: 2250vdcline to line: 1450vdc ? temperature range: -25c to +85c * medical application (unit: mm) 52.0 + - - 0.1 27.0 2x 3.3x90 csk 63.0 100 120 240 220 use only with a 250v fuse 20.5 0.80 typ. 7x 2.80 64.0 51.0 3.5 46.0 52.0 46.5 + - - + - - 0.5 0.1 2x m3 21.0 + 0.5 77 145 algonquin parkway, whippany, nj 07981 ? 973-560-0019 ? fax: 973-560-0076 e-mail: filtersales@powerdynamics.com ? www.powerdynamics.com
attenuation tables & schematics medical applications non-medical applications hgn-369 series example & ordering code current rating (a): schematic: hgn-369 - 1m = 1 = 2= 3 = 4 = 6 insertion loss in db (50 ohm circuit) line l(mh) l(mh) 2200pf 2200pf load n n' e e' p p' 0.033 f line l(mh) l(mh) 0.033 load n n' e e' p p' f 120 vac 100 vac 240 vac 220 vac = blank = m standard type without c(y); c(x) only current rating 1a 2a3a 4a 6a l value 10.3ma 4.6ma2.5ma 1.2ma 0.8ma comm. mode(l-g) mhz diff. mode(l-l) mhz .01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 30 19 34 42 53 57 50 55 55 15 5 5 33 47 71 70 55 6 18 26 37 44 54 51 60 23 8 10 20 33 68 70 60 12 18 25 37 45 53 65 60 16 5 10 24 35 64 65 60 6 16 23 34 40 54 56 65 11 4 4 20 33 63 66 64 6 15 21 30 35 50 55 60 16 6 6 15 28 60 65 60 insertion loss in db (50 ohm circuit) current rating 1a 2a3a 4a 6a l value 10.3ma 4.6ma2.5ma 1.2ma 0.8ma comm. mode(l-g) mhz diff. mode(l-l) mhz .01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 30 22 32 41 51 47 36 31 22 13 8 12 38 52 72 69 41 17 30 38 41 42 37 30 22 17 7 9 25 39 67 70 58 17 28 34 38 38 30 24 18 17 5 10 25 38 67 71 58 10 16 22 30 32 32 30 22 11 5 13 25 36 65 70 60 8 13 19 25 29 29 29 25 10 5 10 25 37 65 70 62 78 145 algonquin parkway, whippany, nj 07981 ? 973-560-0019 ? fax: 973-560-0076 e-mail: filtersales@powerdynamics.com ? www.powerdynamics.com


▲Up To Search▲   

 
Price & Availability of HGN-369-2M

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X