Part Number Hot Search : 
NL17S CUPPB ST3020 L74VHC1G 35709906 M948AP TA8836F FP100
Product Description
Full Text Search
 

To Download LPS62 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  usa: 1-888-41-astec europe (uk): 01384-842211 asia (hk): 852-2437-9662 28 special features ? universal input ? high efficiency ? remote sense ? built-in emi filter ? low output ripple ? adjustable output ? overvoltage protection ? overload protection ? enclosure kit available (see page 56 or powerfax doc. no 1025) environmental operating temperature: 0 to 50 c ambient derate each output at 2.5% per degree from 50 to 70 c electromagnetic susceptibility: designed to meet iec 801, -2, -3, -4, -5, -6, level 3 humidity: operating; non-condensing 5% to 95% vibration: three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 g peak 5 hz to 500 hz, operational storage temperature: -40 to 85 c temperature coefficient: .04% per c mtbf demonstrated: >550,000 hours at full load and 25 c ambient conditions lps 60 60 watts electrical specifications input input range ........................... 85-264 vac 120-370 vdc frequency ............................ 47-440 hz inrush current ....................... <18 a peak @ 115 vac; <36 a peak @ 230 vac, cold start @ 25 c input current ......................... 1.5 a max. (rms) @ 115 vac efficiency .............................. 70% typical at full load emi filter ............................... fcc class b conducted cispr 22 class b conducted en55022 class b conducted vde 0878 pt3 class b conducted safety ground leakage current .................... <0.5 ma @ 50/60 hz, 264 vac input output maximum power ................... 60 w for convection; 80 w with 30 cfm forced air adjustment range ................. -5, +10% minimum hold-up time ......................... 20 ms @ 60 w load, 115 vac nominal line overload protection .............. short circuit protection on all outputs. case overload protected @ 110-145% above peak rating overvoltage protection ......... 5 v output: 5.7-6.7 vdc. other outputs 10% to 25% above nominal output remote sense ...................... compensates for 0.5 v lead drop min. will operate without remote sense connected. reverse connection protected. safety vd e 0805/en60950 (iec950 ) 11774-3336-1255 (lc #86665) u l ul195 0 e132002 cs a csa 22.2-234 level 3 lr53982c nemk o en 60950/emko-tu e p95100123 (74-sec) 203 bab t en60950/bs700 2 ps / 605272 cb certificate and report 1521, 1522, 1523, 1524 ce mark (lvd) total power 60 - 80 w atts input voltages 85 - 264 v a c 120 - 370 vdc lps 60 series # of outputs single
power fax: 760-930-0881 29 low power low power astec america 5810 van allen way carlsbad, ca 92008 telephone: 760-930-4600 facsimile: 760-930-0698 astec europe astec house, waterfront business park merry hill, dudley west midlands, dy5 1lx, uk telephone: 01384-842211 facsimile: 01384-843355 astec asia 6f., china dyeing works building 382-392 castle peak road tsuen wan, n.t., hong kong telephone: 852-2437-9662 facsimile: 852-2402-4426 doc no: 1017 ? rev 5.5.99 drawings ordering information model output minimum maximum load with maximum load with peak regulation 2 ripple number voltage load convection cooling 30 cfm forced air load 1 p/p (pard) 3 lps61 3.3 v 2 a 12 a 16 a 18 a 2% 33 mv LPS62 5 v 0 a 12 a 16 a 18 a 2% 50 mv lps63 12 v 0 a 5 a 6.7 a 7.5 a 2% 120 mv lps64 15 v 0 a 4 a 5.3 a 6 a 2% 150 mv lps65 24 v 0 a 2.5 a 3.3 a 3.8 a 2% 240 mv lps68 48 v 0 a 1.3 a 1.7 a 1.9 a 2% 480 mv 1. peak current lasting <30 seconds with a maximum 10% duty cycle. 2. at 25 c including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. peak-to-peak with 20 mhz bandwidth and 10 m f in parallel with a 0.1 m f capacitor at rated line votlage and load ranges. 3.00" (76.2) 2.55" (64.8) 0.22" (5.6) 0.22" (5.6) 4.56" (115.8) 5.00" (127) 1.65" (41.9) 0.12" (3) sk 1 sk 2 1 2 3 4 5 6 0.15" (4) dia (4 places) gnd 1 3 n l m1 m2 remote sense connector _ + sk201 voltage adj. pot mating connectors ac input: molex 09-50-8031 (usa) 09-91-0300 (uk) pins: 08-58-0111 dc outputs: molex 09-50-8061 (usa) 09-91-0600 (uk) pins: 08-58-0111 remote sense: molex 22-01-2025 pins: 08-50-0114 notes 1. specifications subject to change without notice. 2. all dimensions in inches (mm), tolerance is .02. 3. mounting holes m1 and m2 should be grounded for emi purposes. 4. mounting hole m1 is safety ground connection. 5. specifications are for convection rating at factory settings at 115 vac input, 25 c unless otherwise stated. 6. warranty: 1 year 7. weight: 0.75 lb. / 0.34 kg lps60 power derating curve output power (watts) 0 c 20w 40w 60w 80w 10 c20 c30 c40 c50 c60 c70 c ta ?ambient temperature ? c 0w natural convection cooling 40w 30w 30 cfm forced air cooling pin assignments connector lps61 LPS62 lps63 lps64 lps65 lps68 sk1-1 neutral neutral neutral neutral neutral neutral sk1-3 line line line line line line sk2-1 3.3 v +5 v +12 v +15 v +24 v 48 v sk2-2 3.3 v +5 v +12 v +15 v +24 v 48 v sk2-3 3.3 v +5 v +12 v +15 v +24 v 48 v sk2-4 common common common common common common sk2-5 common common common common common common sk2-6 common common common common common common sk201-1 +sense +sense +sense +sense +sense +sense sk201-2 -sense -sense -sense -sense -sense -sense


▲Up To Search▲   

 
Price & Availability of LPS62

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X