Part Number Hot Search : 
M38198M AK4383 ICX084AL ACS11D MBR1010 APC18T12 1D41A 384209
Product Description
Full Text Search
 

To Download 4PIN Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  lf-4x flex connectsystem for colormix flex data sheet benefits universal feeder and connector for linearlight colormix flex modules with 8mm ? assembly without tools ? reduced assembly time ? applications connect system for linearlight colormix flex modules, 8mm width ? product technical operating data and ordering guide ean * s-unit * max voltage [v] max current [a] diameter of wire [mm2 / awg] length of wire [mm] lf-4PIN flex 4008321514585 100 25 4 0,14 500 24 / lf-conn-10 flex 4008321955333 200 25 3 0,057 10 30 / lf-conn-150 flex 4008321955340 200 25 3 0,057 150 30 / ean: bag containing 10 pieces s-unit: modules per shipping unit *) technical features feeder lf-4PIN flex for connection of all linearlight flex with power supply ? board to board connection of two flex modules: lf-conn-10 flex for short gaps, lf-conn-150 flex for longer gaps ? allowed operating temperatur suited to linearlight colormix ? connection possible at the reel end or at the cut points ? locking system meets shock and vibration requirements according to iec 60068-2-6/27 ? use only in indoor applications or in luminaires with ip67 rating ? page 1 of 3 lf-4x flex - 22.12.2010
drawings lf-4PIN flex housing pps / polyamide / black isolation of wires pvc / black/red/green/blue lf-conn-10 flex housing pps / polyamide / black isolation of wires aramid paper / white lf-conn-150 flex housing pps / polyamide / black isolation of wires aramid paper / white page 2 of 3 lf-4x flex - 22.12.2010
sales and technical support sales and technical support is given by the local osram subsidiaries. on our world wide homepage all osram subsidiaries are listed with complete address and phone numbers. osram gmbh hellabrunner strasse 1 d - 81536 mnchen germany www.osram.com +49 (0)89 6213-0 related and further information the new dimension of light ? 153 s006 gb www.osram.com/led-systems-downloads optotronic? technical guide ? 130 t008 gb www.osram.com/ecg-downloads optotronic? data sheets ? http://catalog.myosram.com osram led systems ? www.osram.com/led-systems new standards for led control gear ? 130 w011 gb www.osram.com/ecg-download datasheets for lf05a, lf05e, lf06p ? 153 s006 gb www.osram.com/led-systems-downloads safety information installation of led modules (with power supplies) needs to be made with regard to all applicable electrical and safety standard s. only qualified personnel should be allowed to perform installations. ? ? all components of the connectsystem flex must be assembled to avoid any stress on the wires and/or board connectors. the installer must ensure that there is adequate strain relief between the board connection and the wiring. ? in order to maintain adequate electrical contact, please refrain from repeat removal, maximum of 5, of the connectsystem flex. ? the connector has no inverse polarity protection. there will be no electrical function if connector is not well positioned or i f polarity is inverse. several modules can be damaged (see the respective module data sheet). ? the maximum operation current on page 1 may not be exceeded. ? the connectsystem flex is designed for indoor application only. any unprotected outdoor use is not allowed. ? a suitable enclosure ip67 is required if the system is to be exposed to humidity and /or dust. condensation water in the ip67 enclosure is not allowed. assembly information ? for electrical connection of the linearlight flex modules open the locker by pulling and place the module in the slot. the "up" mark of the connectsystem flex must face towards to front si de of the led module for an electrical connection between the solder pads and the connectsystem flex. the connectsystem flex is locked by pushing locking bar back. ? pay attention to the correct polarity between feeder lf-4PIN flex and led module and power supply: - for the feeder lf-4PIN flex connect the blue cable to the seperated solder pad marked with a b (the ca version has the marking on the opposite site of the connector) - connect the '+' pole of the power supply to the black cable an d the red, green, blue cables to the rgb contacts of the power supply ? particular attention is required when using the connector for bo ard to board connection: the '+' pole of the first module has t o be connected to the '+' pole of the second module. in case of wrong polarity no light will be emitted and the moules can be damage d (see the respective module data sheet). page 3 of 3 lf-4x flex - 22.12.2010


▲Up To Search▲   

 
Price & Availability of 4PIN

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X