Part Number Hot Search : 
CY7C1399 IDT71V 30T85 10D218 CM718 239400P VSC6424 IZ1236MR
Product Description
Full Text Search
 

To Download JAK05-5R0 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  speci?cations which provide more details for the proper and safe use of the described product are available upon request. all speci?cations are subject to change without notice. power supplies jak series ac input single output, general-purpose features ? low pro?le, single output ac.100v input power supply. ? compact open frame type. ? these low noise power supplies are fcc class b standard com- pliant. ? low price. part numbers and ratings output voltage(v) 10w type 15w type 25w type current(a) part no. current(a) part no. current(a) part no. 5 2 jak05-2r0 3 jak05-3r0 5 JAK05-5R0 12 0.84 jak12-r84 1.3 jak12-1r3 2.1 jak12-2r1 15 0.67 jak15-r67 1 jak15-1r0 1.7 jak15-1r7 24 0.42 jak24-r42 0.63 jak24-r63 1.1 jak24-1r1 output voltage(v) 50w type 100w type 150w type current(a) part no. current(a) part no. current(a) part no. 5 10 jak05-10r 20 jak05-20r 30 jak05-30r 12 4.2 jak12-4r2 8.4 jak12-8r4 12.5 jak12-13r 15 3.4 jak15-3r4 6.7 jak15-6r7 10 jak15-10r 24 2.1 jak24-2r1 4.2 jak24-4r2 6.3 jak24-6r3
speci?cations which provide more details for the proper and safe use of the described product are available upon request. all speci?cations are subject to change without notice. power supplies jak series ac input single output, general-purpose specifications 10w type * 1 current rating(maximum output current) is determined for C10 to +40c. derating is required when used outside this temperature range. * 2 when under load, output is cut off if the input voltage is below the minimum input voltage continuously for more than 1s. part no. jak05-2r0 jak12-r84 jak15-r67 jak24-r42 output voltage, current * 1 5v ? 2a 12v ? 0.84a 15v ? 0.67a 24v ? 0.42a maximum output power w 10 10.1 10.1 10.1 input requirements input voltage eac * 2 v 85 to 132[rating:100-120] input frequency hz 47 to 66[single phase] input current a 0.3max.[100v] fuse rating a 1.6[internal] surge current a 40max.[100/120v] leakage current ma 0.5max.[100/120v] ef?ciency % 70typ. 72typ. 73typ. 74typ. output characteristics output voltage v 5 12 15 24 voltage variable range v 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 21.6 to 26.4 maximum output current * 1 a 2 0.84 0.67 0.42 overvoltage threshold v 5.6 to 6.9 13.4 to 15.7 16.7 to 19 26.7 to 30.5 overcurrent threshold a 2.1min. 0.9min. 0.7min. 0.44min. voltage stability input variation % 2max.(1typ.)[within the input voltage range] total variation 3max.(1typ.) load variation % 2max.(1typ.)[10 to 100% load] temperature variation % 2max.(1typ.)[0 to +40c] drift % 0.5max.(0.1typ.)[after input voltage on for 30min to 8h] dynamic load %/ms 4max./1max.[50 to 100% sudden load change] ripple noise ep-p mv 120max. 190max. 220max. 310max. start up time ms 500max.[100v] hold up time ms 15min.(17typ.)[100v] accessory equipment operation indicator none overvoltage protection voltage shielding type, recovers upon reset(interval approx. 40s). overcurrent protection fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded. remote on-off none remote sensing none output voltage external variable function none standards safety standards ul1950d3 recognized. noise terminal voltage vcci class 2, fcc class b compliant. construction external dimensions h w lmm 19 60 77 weight g 65max. mounting method 1 side(open frame)
speci?cations which provide more details for the proper and safe use of the described product are available upon request. all speci?cations are subject to change without notice. power supplies jak series ac input single output, general-purpose specifications 15w type * 1 current rating(maximum output current) is determined for C10 to +40c. derating is required when used outside this temperature range. * 2 when under load, output is cut off if the input voltage is below the minimum input voltage continuously for more than 1s. part no. jak05-3r0 jak12-1r3 jak15-1r0 jak24-r63 output voltage, current * 1 5v ? 3a 12v ? 1.3a 15v ? 1a 24v ? 0.63a maximum output power w 15 15.6 15 15.1 input requirements input voltage eac * 2 v 85 to 132[rating:100-120] input frequency hz 47 to 66[single phase] input current a 0.4max.[100v] fuse rating a 1.6[internal] surge current a 40max.[100/120v] leakage current ma 0.5max.[100/120v] ef?ciency % 71typ. 72typ. 73typ. 74typ. output characteristics output voltage v 5 12 15 24 voltage variable range v 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 21.6 to 26.4 maximum output current * 1 a 3 1.3 1 0.63 overvoltage threshold v 5.6 to 6.9 13.4 to 15.7 16.7 to 19 26.7 to 30.5 overcurrent threshold a 3.2min. 1.4min. 1.05min. 0.66min. voltage stability input variation % 2max.(1typ.)[within the input voltage range] total variation 3max.(1typ.) load variation % 2max.(1typ.)[10 to 100% load] temperature variation % 2max.(1typ.)[0 to +40c] drift % 0.5max.(0.1typ.)[after input voltage on for 30min to 8h] dynamic load %/ms 4max./1max.[50 to 100% sudden load change] ripple noise ep-p mv 120max. 190max. 220max. 310max. start up time ms 500max.[100v] hold up time ms 15min.(17typ.)[100v] accessory equipment operation indicator none overvoltage protection voltage shielding type, recovers upon reset(interval approx. 40s). overcurrent protection fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded. remote on-off none remote sensing none output voltage external variable function none standards safety standards ul1950d3 recognized. noise terminal voltage vcci class 2, fcc class b compliant. construction external dimensions h w lmm 19 60 95 weight g 85max. mounting method 1 side(open frame)
speci?cations which provide more details for the proper and safe use of the described product are available upon request. all speci?cations are subject to change without notice. power supplies jak series ac input single output, general-purpose specifications 25w type * 1 current rating(maximum output current) is determined for C10 to +40c. derating is required when used outside this temperature range. * 2 when under load, output is cut off if the input voltage is below the minimum input voltage continuously for more than 1s. part no. JAK05-5R0 jak12-2r1 jak15-1r7 jak24-1r1 output voltage, current * 1 5v ? 5a 12v ? 2.1a 15v ? 1.7a 24v ? 1.1a maximum output power w 25 25.2 25.5 26.4 input requirements input voltage eac * 2 v 85 to 132[rating:100-120] input frequency hz 47 to 66[single phase] input current a 0.65max.[100v] fuse rating a 1.6[internal] surge current a 40max.[100/120v, 25c cold start] leakage current ma 0.5max.[100/120v] ef?ciency % 78typ. 79typ. 81typ. 82typ. output characteristics output voltage v 5 12 15 24 voltage variable range v 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 21.6 to 26.4 maximum output current * 1 a 5 2.1 1.7 1.1 overvoltage threshold v 5.6 to 6.9 13.4 to 15.7 16.7 to 19 26.7 to 30.5 overcurrent threshold a 5.3min. 2.2min. 1.8min. 1.2min. voltage stability input variation % 2max.(1typ.)[within the input voltage range] total variation 3max.(1typ.) load variation % 2max.(1typ.)[10 to 100% load] temperature variation % 2max.(1typ.)[0 to +40c] drift % 0.5max.(0.1typ.)[after input voltage on for 30min to 8h] dynamic load %/ms 4max./1max.[50 to 100% sudden load change] ripple noise ep-p mv 120max. 190max. 220max. 310max. start up time ms 500max.[100v] hold up time ms 15min.(17typ.)[100v] accessory equipment operation indicator none overvoltage protection voltage shielding type, recovers upon reset(interval approx. 40s). overcurrent protection fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded. remote on-off none remote sensing none output voltage external variable function none standards safety standards ul1950d3 recognized. noise terminal voltage vcci class 2, fcc class b compliant. construction external dimensions h w lmm 25 60 110 weight g 150max. mounting method 1 side(open frame)
speci?cations which provide more details for the proper and safe use of the described product are available upon request. all speci?cations are subject to change without notice. power supplies jak series ac input single output, general-purpose specifications 50w type * 1 current rating(maximum output current) is determined for C10 to +40c. derating is required when used outside this temperature range. * 2 when under load, output is cut off if the input voltage is below the minimum input voltage continuously for more than 1s. part no. jak05-10r jak12-4r2 jak15-3r4 jak24-2r1 output voltage, current * 1 5v ? 10a 12v ? 4.2a 15v ? 3.4a 24v ? 2.1a maximum output power w 50 50.4 51 50.4 input requirements input voltage eac * 2 v 85 to 132[rating:100-120] input frequency hz 47 to 66[single phase] input current a 1.3max.[100v] fuse rating a 3.15[internal] surge current a 40max.[100/120v, 25c cold start] leakage current ma 0.5max.[100/120v] ef?ciency % 77typ. 79typ. 79typ. 81typ. output characteristics output voltage v 5 12 15 24 voltage variable range v 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 21.6 to 26.4 maximum output current * 1 a 10 4.2 3.4 2.1 overvoltage threshold v 5.6 to 6.9 13.4 to 15.7 16.7 to 19 26.7 to 30.5 overcurrent threshold a 10.5min. 4.4min. 3.5min. 2.2min. voltage stability input variation % 2max.(1typ.)[within the input voltage range] total variation 3max.(1typ.) load variation % 2max.(1typ.)[10 to 100% load] temperature variation % 2max.(1typ.)[0 to +40c] drift % 0.5max.(0.1typ.)[after input voltage on for 30min to 8h] dynamic load %/ms 4max./1max.[50 to 100% sudden load change] ripple noise ep-p mv 120max. 190max. 220max. 310max. start up time ms 500max.[100v] hold up time ms 15min.(17typ.)[100v] accessory equipment operation indicator none overvoltage protection voltage shielding type, recovers upon reset(interval approx. 40s). overcurrent protection fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded. remote on-off none remote sensing none output voltage external variable function none standards safety standards ul1950 recognized, japan electric/electronic products control law conformed. noise terminal voltage vcci class 2, fcc class b compliant. construction external dimensions h w lmm 30 60 156 weight g 220max. mounting method 1 side(open frame)
speci?cations which provide more details for the proper and safe use of the described product are available upon request. all speci?cations are subject to change without notice. power supplies jak series ac input single output, general-purpose specifications 100w type * 1 current rating(maximum output current) is determined for C10 to +40c. derating is required when used outside this temperatur e range. * 2 output can stop if input voltage drops below the minimum value continuously for over 1min during supply of power to load. part no. jak05-20r jak12-8r4 jak15-6r7 jak24-4r2 output voltage, current * 1 5v ? 20a 12v ? 8.4a 15v ? 6.7a 24v ? 4.2a maximum output power w 100 100.8 100.5 100.8 input requirements input voltage eac v 85 to 132[rating:100-120] input frequency hz 47 to 66[single phase] input current a 2.5max.[100v] fuse rating a 5[internal] surge current a 25max.[100/120v, 1st surge current, reset after roughly 10s min.] leakage current ma 0.5max.[100/120v] ef?ciency % 81typ. 83typ. 84typ. 85typ. output characteristics output voltage v 5 12 15 24 voltage variable range v 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 21.6 to 26.4 maximum output current * 1 a 20 8.4 6.7 4.2 overvoltage threshold v 5.6 to 6.9 13.4 to 15.7 16.7 to 19 26.7 to 30.5 overcurrent threshold a 21min. 8.9min. 7.1min. 4.5min. voltage stability input variation % 2max.(1typ.)[within the input voltage range] total variation 3max.(1typ.) load variation % 2max.(1typ.)[10 to 100% load] temperature variation % 2max.(1typ.)[0 to +40c] drift % 0.5max.(0.1typ.)[after input voltage on for 30min to 8h] dynamic load %/ms 4max./1max.[50 to 100% sudden load change] ripple noise ep-p mv 120max. 190max. 220max. 310max. start up time ms 500max.[100v] hold up time ms 15min.(23typ.)[100v] accessory equipment operation indicator none overvoltage protection voltage shielding type, recovers upon reset(interval approx. 40s). overcurrent protection * 2 fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded. remote on-off none remote sensing none output voltage external variable function none standards safety standards ul1950 recognized, japan electric/electronic products control law conformed. noise terminal voltage vcci class 2, fcc class b compliant. construction external dimensions h w lmm 35 60 222 weight g 550max. mounting method 1 side(open frame)
speci?cations which provide more details for the proper and safe use of the described product are available upon request. all speci?cations are subject to change without notice. power supplies jak series ac input single output, general-purpose specifications 150w type * 1 current rating(maximum output current) is determined for C10 to +40c. derating is required when used outside this temperature range. * 2 output can stop if input voltage drops below the minimum value continuously for over 1min during supply of power to load. part no. jak05-30r jak12-13r jak15-10r jak24-6r3 output voltage, current * 1 5v ? 30a 12v ? 12.5a 15v ? 10a 24v ? 6.3a maximum output power w 150 150 150 151.2 input requirements input voltage eac v 85 to 132[rating:100-120] input frequency hz 47 to 66[single phase] input current a 3.5max.[100v] fuse rating a 6.3[internal] surge current a 25max.[100/120v, 1st surge current, reset after roughly 10s min.] leakage current ma 0.5max.[100/120v] ef?ciency % 80typ. 83typ. 84typ. 85typ. output characteristics output voltage v 5 12 15 24 voltage variable range v 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 21.6 to 26.4 maximum output current * 1 a 30 12.5 10 6.3 overvoltage threshold v 5.6 to 6.9 13.4 to 15.7 16.7 to 19 26.7 to 30.5 overcurrent threshold a 31.5min. 13.2min. 10.5min. 6.7min. voltage stability input variation % 2max.(1typ.)[within the input voltage range] total variation 3max.(1typ.) load variation % 2max.(1typ.)[10 to 100% load] temperature variation % 2max.(1typ.)[0 to +40c] drift % 0.5max.(0.1typ.)[after input voltage on for 30min to 8h] dynamic load %/ms 4max./1max.[50 to 100% sudden load change] ripple noise ep-p mv 120max. 190max. 220max. 310max. start up time ms 500max.[100v] hold up time ms 15min.(23typ.)[100v] accessory equipment operation indicator none overvoltage protection voltage shielding type, recovers upon reset(interval approx. 60s). overcurrent protection * 2 fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded. remote on-off none remote sensing none output voltage external variable function none standards safety standards ul1950 recognized, japan electric/electronic products control law conformed. noise terminal voltage vcci class 2, fcc class b compliant. construction external dimensions h w lmm 47 75 222 weight g 700max. mounting method 1 side(open frame)
speci?cations which provide more details for the proper and safe use of the described product are available upon request. all speci?cations are subject to change without notice. power supplies jak series ac input single output, general-purpose terminal designations and functions jak10w terminal no. 1: input terminal(no. 1 pin of cp1) live line. fuse is built in. terminal no. 2: input terminal(no. 3 pin of cp1) neutral line terminal no. 3: input terminal(no. 5 pin of cp1) ground terminal no. 4: ground connect with input terminal(no. 5 pin of cp1). if the power supply is connected electrically to equipment via the spacer, etc., the spacer material should be electrically conductive(spacer contact surface=6mm max. dia.). terminal no. 5: output voltage adjustment clockwise rotation increases output voltage. terminal no. 6: + output terminal(no. 2 pin of cp51) terminal no. 7: C output terminal(no. 1 pin of cp51) jak15w terminal no. 1: input terminal(no. 1 pin of cp1) live line. fuse is built in. terminal no. 2: input terminal(no. 3 pin of cp1) neutral line terminal no. 3: input terminal(no. 5 pin of cp1) ground terminal no. 4: ground connect with input terminal(no. 5 pin of cp1). if the power supply is connected electrically to equipment via the spacer, etc., the spacer material should be electrically conductive(spacer contact surface=6mm max. dia.). terminal no. 5: output voltage adjustment clockwise rotation increases output voltage. terminal no. 6: + output terminals(no. 3 and 4 pins of cp51) terminal no. 7: C output terminals(no. 1 and 2 pins of cp51) jak25w terminal no. 1: input terminal(no. 5 pin of cp1) live line. fuse is built in. terminal no. 2: input terminal(no. 3 pin of cp1) neutral line terminal no. 3: input terminal(no. 1 pin of cp1) ground terminal no. 4: ground connect with input terminal(no. 1 pin of cp1). if the power supply is connected electrically to equipment via the spacer, etc., the spacer material should be electrically conductive(spacer contact surface=6mm max. dia.). terminal no. 5: output voltage adjustment clockwise rotation increases output voltage. terminal no. 6: + output terminals(no. 1and 2 pins of cp51) terminal no. 7: C output terminals(no. 3 and 4 pins of cp51) 1 2 3 4 7.5 clearance ( both product and soldering surface ) 6 7 5 7.5 clearance ( both product and soldering surface ) 7.5 grounding pad ( soldering surface ) clearance ( product surface ) 7.5 grounding pad ( soldering surface ) clearance ( product surface ) 1 2 3 4 6 7 5 7.5 clearance ( both product and soldering surface ) 7.5 clearance ( both product and soldering surface ) 7.5 grounding pad ( soldering surface ) clearance ( product surface ) 7.5 grounding pad ( soldering surface ) clearance ( product surface ) 4 5 6 7 1 2 3 dimensions in mm 9 clearance ( both product and soldering surface ) 9 grounding pad ( soldering surface ) clearance ( product surface ) 9 clearance ( both product and soldering surface ) 9 grounding pad ( soldering surface ) clearance ( product surface )
a122_jak 980911 speci?cations which provide more details for the proper and safe use of the described product are available upon request. all speci?cations are subject to change without notice. power supplies jak series ac input single output, general-purpose terminal designations and functions jak50w terminal no. 1: input terminal(no. 5 pin of cp1) live line. fuse is built in. terminal no. 2: input terminal(no. 3 pin of cp1) neutral line terminal no. 3: input terminal(no. 1 pin of cp1) ground terminal no. 4: ground connect with input terminal(no. 1 pin of cp1). if the power supply is connected electrically to equipment via the spacer, etc., the spacer material should be electrically conductive(spacer contact surface=6mm max. dia.). terminal no. 5: output voltage adjustment clockwise rotation increases output voltage. terminal no. 6: + output terminals(no. 1and 2 pins of cp51) terminal no. 7: Coutput terminals(no. 3 and 4 pins of cp51) terminal no. 8: spacer mounting hole a spacer should be used that is constructed from an insulating material(spacer contact surface=6mm max. dia.). jak100w terminal no. 1: input terminal(no. 5 pin of cp1) live line. fuse is built in. terminal no. 2: input terminal(no. 3 pin of cp1) neutral line terminal no. 3: input terminal(no. 1 pin of cp1) ground terminal no. 4: ground connect with input terminal(no. 1 pin of cp1). if the power supply is connected electrically to equipment via the spacer, etc., the spacer material should be electrically conductive(spacer contact surface=6mm max. dia.). terminal no. 5: output voltage adjustment clockwise rotation increases output voltage. terminal no. 6: + output terminals(no. 1 to 4 pins of cp51) terminal no. 7: C output terminals(no. 5 to 8 pins of cp51) terminal no. 8: spacer mounting hole a spacer should be used that is constructed from an insulating material(spacer contact surface=6mm max. dia.). jak150w terminal no. 1: input terminal(no. 5 pin of cp1) live line. fuse is built in. terminal no. 2: input terminal(no. 3 pin of cp1) neutral line terminal no. 3: input terminal(no. 1 pin of cp1) ground terminal no. 4: ground connect with input terminal(no. 1 pin of cp1). if the power supply is connected electrically to equipment via the spacer, etc., the spacer material should be electrically conductive(spacer contact surface=6mm max. dia.). terminal no. 5: output voltage adjustment clockwise rotation increases output voltage. terminal no. 6: + output terminal(no. 1 to 6 pins of cp51) terminal no. 7: Coutput terminal(no. 1 to 7 pins of cp52) terminal no. 8: spacer mounting hole a spacer should be used that is constructed from an insulating material(spacer contact surface=6mm max. dia.). terminal no. 9: vcc terminal(no. 1 pin of cp2) vcc+ terminal no. 10: vcc terminal(no. 2 pin of cp2) vccC 152v should be applied to the vcc terminals if jak power supplies are used in parallel. an isolated external dc power supply should be used to apply this voltage to the vcc terminals. 4 5 6 7 1 2 3 8 9 clearance ( both product and soldering surface ) 9 clearance ( both product and soldering surface ) 9 grounding pad ( soldering surface ) clearance ( product surface ) 9 grounding pad ( soldering surface ) clearance ( product surface ) 4 8 6 7 5 1 2 3 9 clearance ( both product and soldering surface ) 9 clearance ( both product and soldering surface ) 9 grounding pad ( soldering surface ) clearance ( product surface ) 9 clearance ( both product and soldering surface ) 4 8 6 7 5 1 2 3 10 9 dimensions in mm 9 clearance ( both product and soldering surface ) 9 clearance ( both product and soldering surface ) 9 grounding pad ( soldering surface ) clearance ( product surface ) 9 clearance ( both product and soldering surface )


▲Up To Search▲   

 
Price & Availability of JAK05-5R0

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X