Part Number Hot Search : 
F2201 21272 14547 IRF7380Q AD843AQ BTS141TC C68HC70 MBC05D
Product Description
Full Text Search
 

To Download EUS30-080-NHARC Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  innovative solutions you can count on 4118 14th avenue, unit 4 markham, ontario l3r 0j3 1 - 866 - 740 - 1232 page 1 bus converter eus30 - 080 model www.cd 4power .com eus30 - 080 - 6200 9015 35 _ c0 3 _ 03jan07 features: 48 vin, isolat ed, 6:1 fixed conversion ratio 220 watt output at 48 vin, 55 c, 200 lfm 170 watt output at 38 vin, 55 c, 200 lfm industry standard 1/8 brick footprint remote enable (primary side, positive or negative) over - temperature and over c urrent protection direct para llel operation for higher power rohs compliant table 1 input characteristics notes & conditions (1) min typ. max units input voltage operating range 36 48 55 vdc input voltage absolute maximum 60 vdc turn - on threshold 36 37.5 vdc turn - off threshold 34 35.5 vdc input undervoltage lockout hysteresis voltage 2 vdc turn - on threshold 55 5 7 vdc turn - off threshold 5 6 58 vdc input overvoltage lockout hysteresis voltage 2 vdc maximum input current steady - state (30 a out) 5.4 adc no - load input current enabled state, no load (48 vin) 70 ma disabled input current disabled state (48 vin) 7 ma input reflected ripple current note (8) 25 m a p - p inrush current transient 0.2 a 2 s enable ? negative logic version internal 10 k pull - up to 5 v. on state range off state range - 0.1 2.4 0.8 5.0 vdc vdc enable ? positive logic version internal 100 k pull - down to gnd. on state range off state ra nge 2.4 - 0.1 5.0 0.8 vdc vdc table 2 output characteristics notes & conditions (1) min typ. max units output voltage set point (vo=vin/6 +0/ - 0.5%) vin = 48.0 v, io = 0 a 8.0 vdc output load regulation io = 0 to 30 a 0.5 v output voltage total regulation vin = 36 to 55 v, io = 0 to 30 a 5.3 9.2 vdc vin = 42 to 53 v, io = 0 to 30 a 6.3 8.9 vdc output ripple voltage & noise (2) 20 m hz bandwidth 70 150 mv p - p output current operating range 0 30 a output current share accuracy percent deviation from ideal ( 7 ) < 10 % efficiency vin = 48 v, io = 18 a 95.6 % turn - on time vin present: enable to 90% vout 10 ms start - up inhibi t time enabled: vin applied to 90% vout 120 ms 25% step, 0.1a/ m s, d vo 130 mv transient response (3) recovery time 100 m s maximum output capacitance 3000 m f
innovative solutions you can count on 4118 14th avenue, unit 4 markham, ontario l3r 0j3 1 - 866 - 740 - 1232 page 2 bus converter eus30 - 080 model www.cd 4power .com eus30 - 080 - 6200 9015 35 _ c0 3 _ 03jan07 table 3 protec tion characteristics notes & conditions (1) min typ. max units non - latching 32 35 40 a output over - current shutdown re - start rate 80 msec over temperature shutdown non - latching (4) 125 130 c over temperature restart hysteresis 10 c table 4 general specifications notes & conditions (1) min typ. max units isolation voltage input to output 2250 vdc isolation resistance input to output 10 mohm storage tem perature range - 40 125 c operating temperature range non - condensing (6) - 40 100 c thermal measurement location temperature (6) see mechanical drawing for location 120 c material flammability ul 94v - 0 calculated (bellcore tr - 332) 2.7 x10 6 hrs mtbf demonstrated 1 x10 6 hrs dimensions 2.28?l x 0.9?w x 0.48?h (max) (57.9l x 22.9w x 12.19h mm max) weight 30 grams table 5 standards compliance notes & conditions (5) ul/csa 60950 basic insu lation en60950 certified by tuv notes: (1) vin = 48vdc, ta = 25 c, airflow = 200 lfm for all data unless otherwise noted. (2) output ripple voltage and noise is specified when measured with no external capacitance. (3) transient response is specified without a ca pacitor at the output of the converter. (4) thermal shutdown is monitored at the thermal measurement location (tml) . see ?mechanical information? on page 3 for tml location . (5) see ?safety considerations? shown in figure 1 . (6) de - rating curves are conducted in a controlled environment. end application testing is required to ensure the thermal measurement location temperature is below the maximum specified. recommended airflow direction is from pin 1 to pin 3, or 3 to 1 (transverse to the unit) (7) current share accuracy is optimized when the source and load impedance presented to each converter is equal. (8) input reflected ripple is specified when measured with a 12uh source inductance.
innovative solutions you can count on 4118 14th avenue, unit 4 markham, ontario l3r 0j3 1 - 866 - 740 - 1232 page 3 bus converter eus30 - 080 model www.cd 4power .com eus30 - 080 - 6200 9015 35 _ c0 3 _ 03jan07 mechanical information figure 1 pin assignment table 6 pin # pin name function notes & conditions 1 vi(+) positive input voltage 2 en input enable / disable referenced to vi( - ). positive logic: floating = enabled negative logic: floating = disabled 3 vi( - ) negative input voltage 4 vo( - ) negative output voltage 5 vo(+) positive output voltage
innovative solutions you can count on 4118 14th avenue, unit 4 markham, ontario l3r 0j3 1 - 866 - 740 - 1232 page 4 bus converter eus30 - 080 model www.cd 4power .com eus30 - 080 - 6200 9015 35 _ c0 3 _ 03jan07 efficiency curves figure 2 output voltage vs. current figure 3 eus30-080 efficiency (%) vs. iout (a) and vin (v) 88% 89% 90% 91% 92% 93% 94% 95% 96% 97% 0 5 10 15 20 25 30 35 55vin 48vin 42vin 38vin eus30-080 output voltage (v) vs. current (a) and vin (v) 3 4 5 6 7 8 9 10 0 5 10 15 20 25 30 55 vin 48 vin 42 vin 38 vin
innovative solutions you can count on 4118 14th avenue, unit 4 markham, ontario l3r 0j3 1 - 866 - 740 - 1232 page 5 bus converter eus30 - 080 model www.cd 4power .com eus30 - 080 - 6200 9015 35 _ c0 3 _ 03jan07 thermal derating curves (transverse) tcase=120c figure 4 figure 5 figure 6 eus30-080 iout (a) vs. tamb (c) and air flow (lfm) 48 vin 0 5 10 15 20 25 30 35 25 35 45 55 65 75 85 400 lfm 300 lfm 200 lfm 100 lfm eus30-080 iout (a) vs. tamb (c) and air flow (lfm) 38 vin 0 5 10 15 20 25 30 35 25 35 45 55 65 75 85 400 lfm 300 lfm 200 lfm 100 lfm eus30-080 pout (w) vs. tamb (c) and vin (v) at 200 lfm air flow 0 25 50 75 100 125 150 175 200 225 250 275 25 35 45 55 65 75 85 55vin 48vin 38vin
innovative solutions you can count on 4118 14th avenue, unit 4 markham, ontario l3r 0j3 1 - 866 - 740 - 1232 page 6 www.cd 4power .com eus30 - 080 - 6200 9015 35 _ c0 3 _ 03jan07 bus converter eus30 - 080 model turn - on from vin (enable on) turn - on from enable (vin present) figure 7 ch 1 : vin; ch2: vout figure 8 ch3: enable; ch2: vout vin=48v, io=30a, co=3000uf vin=48v, io=30a, co=3000uf output ripple/noise figure 9 vin=48v, io= 3 0a 30.0c 120.0c 40 60 80 100 120 q4: 115.5 q3: 102.7 l1: 76.9 t1: 81.8 d2: 82.3 q1: 77.1 q2: 78.8 therma l image vi= 3 8 v, iout= 3 0 a, 200 lfm top side figure 1 0 air - flow
innovative solutions you can count on 4118 14th avenue, unit 4 markham, ontario l3r 0j3 1 - 866 - 740 - 1232 page 7 www.cd 4power .com eus30 - 080 - 6200 9015 35 _ c0 3 _ 03jan07 bus converter eus30 - 080 model safety considerations figure 1 1 ordering information the eus series of converters are certified to the standards listed in the ?standards compliance? section in the table a bove. if this product is built into information technology equipment, the installation must comply with the above standard. an external input fuse (10 a recommended), must be used to meet the above requirements. the output of the converter [vo(+)/vo( - )] i s considered to remain within selv limits when the input to the converter meets selv or tnv - 2 requirements. the converters and materials meet ul 94v - 0 flammability ratings. c&d technologies, inc. reserves the right to alter or improve the specification, in ternal design or manufacturing process at any time, without notice. please check with your supplier or visit our website to ensure that you have the current and complete specification for your product before use. ? c&d technologies, inc. 200 7 no part of this publication may be copied, transmitted, or stored in a retrieval system or reproduced in any way including, but not limited to, photography, photocopy, magnetic or other recording means, without prior written permission from c&d technologies, inc. in structions for use are available from: www.cd 4power .com rohs compl ia nt the eus series of c onverter s is in compliance with the european union directive 2002/95/ec (rohs) with repsect to the following sustances: lead (pb), mercury (hg), cadmium (cd), hexav alent chromium, polybrominated biphenyls (pbb) or polybrominated diphenyl ethers (pbde).


▲Up To Search▲   

 
Price & Availability of EUS30-080-NHARC

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X