teledyne relays industrial solid state products page 38 specifications subject to change without notice igtd series single igbt dc output to 100 amps 1200 volts part numbers package & max blocking input type output options chip type voltage (piv)/ (note 2) current line rating amps igtd -igbt 1200480 r~l or r~h 25 see table 600240 -dc input, 50 random 75 below and turn-on 100 page 58 a~l or a~h -ac input random turn-on options (add suffix to part number) - see page 58 for full description -006 faston terminals -007 -65 c operation -010 #8-32 load terminal hardware -012 ez mount tm -014 plastic cover -016 mov -026 non-floating output terminals part number example: igtd1200480r25-l-012 mechanical specification features/benefits ? industry standard package ? high temperature plastic housing for exceptional mechanical ruggedness. ? igbt output. ? choice of ac or dc input versions. ? constant current input minimizes source current requirement. ? exposed ceramic baseplate for reduced thermal resistance and best thermal performance. ? constructed using teledynes unique powerther tm or fused copper tm (for higher cmurrent models) processes. these processes yield superior thermal impedance and power cycling capabilities through reduced thermal interconnections, allowing for cooler, more reliable operation. ? the logic drive circuitry section uses the latest in reliable surface mount technology. ? certifications: - ul and ulc recognized file #e128555 typical applications ? electromechanical line relay replacement. ? industrial and process controls. ? programmable controller interface. ? robotics motor position and speed controls. general description the igtd series dc solid state relays are designed to control high power loads in the industry standard package. optical isolation ensures complete protection of control elements from load transients. teledynes advanced design featuring the powertherm tm or fused copper tm processes offers users superior thermal management resulting in superior performance, quality and reliability. .170 dia. thru (2) (plcs.) (4.32) #10-32 thread #6-32 thread 1.70 (43.18) 1.87 (47.5) 2.25 (57.15) 1.75 (44.45) 1.00 (25.4) 0.50 (12.7) 1.10 (27.94) 1.301 (30.71) + 0.75 (19.05) 0.25 (6.35) 1.037 (26.34) c l teledyne relays solid state relays output input 3 to 32 vdc + block diagram dc line or load load detection/ control circuit control voltage + opto isolated control + snubber standard
electrical specifications teledyne relays industrial solid state products industrial solid state products ? 800-436-8766 ? www.teledynerelays.com page 39 output (load) specifications (contd) parameter output current min max units output current rating 25 25 (load current 50 50 a @85 c) 75 75 100 100 25 190 pulsed current rating 50 240 a 75 480 100 480 thermal resistance 25 0.5 junction to case (j c ) 50 0.33 c/w 75 0.2 100 0.2 power dissipation 25 110 (tc = 85 c) 50 175 w 75 500 100 500 input (control) specifications load voltage/ parameter input code min max units 600240r~l 3.5 15 1200480r~l 3.5 15 control voltage range 600240r~h 15 32 vdc (note 2) 1200480r~h 15 32 600240a~l 90 140 1200480a~l 90 140 600240a~h 140 280 vac 1200480a~h 140 280 input current r~l (@5vdc) 30 r~h (@15vdc) 30 a~l(@140vac) 30 a~h(@280vac) 30 must turn-off voltage r 2 vdc a10 vac reverse voltage r -32 vdc protection a n/a turn-off current r 1 ma(dc) a 1 ma(ac) output (load) specification parameter voltage code min max units 600240 24 400 1200480 48 800 frequency range 75 hz 600240 600 1200480 1200 on-state voltage drop 2.5 v @ max rated current turn-on time 4.8 ms turn-off time 0.16 ms leakage current (off-state) 1 ma @25 c dv/dt (typical) 500 v/ m s isolation (all terminals to heatsink) = vrms for 1 min with unit mounted properly 2500 v operating temperature -40 125 c power factor range 0.5 1.0 igtd series single igbt dc output to 100 amps 1200 volts notes: 1.) where overvoltage transient spikes are present, suppression may be required. a suppressor and/or a snubber circuit across the ac terminals of the module will provide additional transient immunity. 2.) indicate high or low control voltage range by adding -l or -h to part number before options. see part number example on previous page. ma load voltage rating vdc vpeak over voltage range
|