  ? 2004 teledyne relays (800) 284-7007 ? www.teledynerelays.com c63 page 1 2dsC63-10 rev -- 1.0a, 60 vdc optically isolated short-circuit protected features/benefits ? short-circuit protected: prevents damage to system components, assemblies and system wiring ? optical isolation: isolates control circuits from load transients and eliminates ground loops and signal ground noise ? low off-state leakage ? switches high currents: to 1.0 amp ? high noise immunity: control signals isolated from switching noise ? high dielectric strength: for safety and for protection of control and signal level circuits description the C63-10 solid-state relay utilizes a power fet switch that is protected against short circuits and overload currents. the short-circuit protection feature provides protection when a short or overload occurs while the relay is on as well as when the relay is switched into an overload. in either case, the relay will sense the overload condition and then block it inde?nitely until the overload is removed and the unit is reset by cycling the input control. using the C63-10 to switch power sources and loads prevents damage to system assemblies and system wiring. the power fet output offers low on resistance and can switch loads in either the high or the low side of the power line. the C63-10 is packaged in a 6-pin dip package . part number description C63-10 1a, 60 vdc short-circuit protected solid-state relay for through-hole mounting sC63-10 1a, 60 vdc short-circuit protected solid-state relay for surface mount electrical specifications (C40c to +85c ambient temperature unless otherwise speci?ed) input (control) specifications min max units input current 8 20 ma input voltage @ 10 ma 2 3 vdc must turn-on 8 ma must turn-off current 100 a must turn-off voltage 0.8 vdc reverse polarity C6 vdc C63-10 series output (load) specifications min max units load voltage range 0 60 vdc output current rating (see figure 4) 1.0 a leakage current at rated voltage 10 a transient blocking voltage @25c 100 vdc output capacitance @25vdc (25c) 600 pf output voltage drop @1a 0.55 vdc on resistance 0.55 ohm turn-on time 2.0 ms turn-off time 1.0 ms trip overload (see figure 7) a
c63 page 2 specifications ar e under revision control ? 2004 teledyne relays 2dsC63-10 rev -- C63-10 series general specifications (+25c ambient temperature unless otherwise speci?ed) environmental specification min max units operating temperature C 40 +85 c storage temperature C 40 +100 c junction temperature @ 1a +125 c thermal resistance ja 125 c/w dielectric strength 1000 vac insulation resistance (@500 vdc) 10 9 ohm input to output capacitance 5 pf resistance to soldering heat mil std 202, method 210 solderability mil std 202, method 208 thermal shock mil std 202, method 107 functional block diagram figure 3 *shorted internally **series resistor required to limit input current to 20ma maximum figure 2 typical wiring diagram +in (1) input with leds Cin (3) optical isolation detection circuit switching circuit output switch (mosfet) with current sense +out (6) Cout (4) load load * * 6 5 4 1 2 3 rs ** c63 mechanical specification figure 1
? 2004 teledyne relays (800) 284-7007 ? www.teledynerelays.com c63 page 3 2dsC63-10 rev -- typical overload trip current vs. time figure 7 C63-10 series control current vs. input voltage figure 4 figure 6 load current vs. ambient temperature typical turn-on time vs. input current figure 5 notes: 1. the C63-10 relays input current should be limited to between 8 and 20ma. an external resistor whose value =(v in C 2.5 volts) 0.012 amps is a good choice for limiting input current. 2. relay input transitions should be less than 1.0 millisecond. 3. loads may be attached to either the positive or negative output terminal. 4. maximum load current ratings are with the relay in free air and soldered to a printed circuit board. 5. timing is measured from the input current transition to the 10% or 90% points on the output voltage transition. 6. overload conditions (including shorted loads) are speci?ed for load supply voltages to 60 vdc maximum. 7. for through-hole-pcb-solder-attaching C63-10 series relays, the wave-solder or solder pot operations are limited to +260c maximum for 10 seconds, maximum. 8. for surface-mount-solder-attaching sC63-10 series relays, in ir heating or convection heating systems, the component temperature is limited to +235c maximum for 10 seconds maximum.


▲Up To Search▲   

 
Price & Availability of C63-10

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X