3-phase ? lters fn 3270 compact three-phase emc/rfi ? lter for industrial motor drive applications approvals very compact and light weight design requiring minimum space easy, time-saving installation and contacting protective covers as optional accessory available attenuation performance according to en 61800-3/a11 typical applications an extremely compact and light weight filter design requiring minimum mounting space in installations and cabinets. simple and time-saving installation with good accessibility for automatic and hand tools. solid, touch-safe terminal blocks, for all filters from 10 to 100a, offering sufficient contacting cross section according to the en 60204-1 installation standard. optionally available transparent protective covers for all filters with busbars from 150 to 1000a, to protect the installer, operator or inspector from undeliberate touching of life conductors. they can easily be retro- fitted even if the filter is already installed and connected. these emc filters provide the attenuation performance needed to fulfill en 61800-3/a11. guaranteed filter performance under full- load operating conditions. 15 different filter models allow the specific choice and deployment for most industrial applications. variable speed electrical power drive systems/motor drives for mainly industrial purpose various industrial applications comprising frequency inverters, motor drives and servo drives features and benefits technical specifications maximum continuous operating voltage: 3x 520/300vac (480vac +10% possible) operating frequency: dc to 60hz rated currents: 10 to 1000a @ 50c high potential test voltage: p C> e 2750vdc for 2 sec p C> p 2250vdc for 2 sec protection category: ip20 (10 to 100a) ip00 (150 to 1000a) overload capability: 4x rated current at switch on, 1.5x rated current for 1 minute, once per hour temperature range (operation and storage): -25c to +100c (25/100/21) flammability corresponding to: ul 94v-2 or better design corresponding to: ul 1283, csa 22.2 no. 8 1986, iec/en 60939 mtbf @ 50c/400v (mil-hb-217f): >320,000 hours typical electrical schematic l1 l2 l3 line cx r1 l cy l1 l2 load l3 cx pe r2 pe
> components > fn 3270 filter rated current typical drive leakage current** power loss input/output weight protective @ 50c (40c) power rating* @ 480vac/50hz @ 25c/50hz connections covers*** [a] [kw] [ma] [w] [kg] order code filter selection table fn 3270h-10-44 10 (11) 5.5 26.4 2.4 -44 0.4 fn 3270h-20-44 20 (22) 11 26.4 4.1 -44 0.5 fn 3270h-35-33 35 (38) 22 29.4 6.8 -33 0.7 fn 3270h-50-34 50 (55) 30 29.4 12.8 -34 1.2 fn 3270h-65-34 65 (71) 37 29.4 13.5 -34 1.3 fn 3270h-80-35 80 (88) 45 29.4 13.5 -35 2.2 fn 3270h-100-35 100 (110) 55 29.4 17.1 -35 2.6 fn 3270h-150-99 150 (164) 75 59.5 7.5 -99 6.1 1151-047 fn 3270h-200-99 200 (219) 110 59.5 13.2 -99 6.1 1151-047 fn 3270h-250-99 250 (274) 132 59.5 20.6 -99 6.1 1151-047 fn 3270h-320-99 320 (350) 160 59.5 12.2 -99 7.2 1151-047 fn 3270h-400-99 400 (438) 220 59.5 19.2 -99 7.2 1151-047 fn 3270h-600-99 600 (657) 315 59.5 35.6 -99 7.7 1151-047 fn 3270h-800-99 800 (876) 400 59.5 51.8 -99 15.8 1151-049 fn 3270h-1000-99 1000 (1095) 560 59.5 81.0 -99 15.8 1151-049 * calculated at rated current, 480vac and cos phi = 0.8. the exact value depends upon the efficiency of the drive, the motor an d the entire application. ** maximum leakage under normal operating conditions. note: if two phases are interrupted, worst case leakage could reach 5.2 t imes higher levels. *** please contact your local schaffner partner to order the optional protective covers with the order code in the table above. per cispr 17; a = 50/50 sym; b = 50/50 asym; c = 0.1/100 sym; d = 100/0.1 sym typical filter attenuation 10 and 20a types 35 to 65a types 80 and 100a types 150 to 1000a types
> components > fn 3270 your local partner: to find your local partner within schaffners global network, please go to www.schaffner.com may 2008 mechanical data 10 to 100a types 150 to 1000a types a c b e g f j a j h h di k c l i e g f l m o b p n w z v x y d u u all dimensions in mm; 1 inch = 25.4mm tolerances according: iso 2768-m / en 22768-m 10a 20a 35a 50a 65a 80a 100a 150a 200a 250a 320a 400a 600a 800a 1000a dimensions a 150 150 160 170 170 200 230 300 300 300 300 300 300 370 370 b 58 58 70 85 85 95 95 200 200 200 200 200 200 190 190 c 58 58 68 80 80 90 90 86 86 86 86 86 86 125 125 d 120 120 130 140 140 170 200 240 240 240 240 240 240 310 310 e 132.5 132.5 142.5 152.5 152.5 182.5 212.5 275 275 275 275 275 275 345 345 f 42 42 50 65 65 75 75 165 165 165 165 165 165 155 155 g 4.5 4.5 5.5 5.5 5.5 5.5 5.5 ?11 ?11 ?11 ?11 ?11 ?11 ?11 ?11 h 1 1 1 1 1 1.5 1.5 2 2 2 2 2 2 3 3 i 21.9 21.9 25 39 39 45 45 40 40 40 40 40 40 50 50 j m4 m4 m5 m6 m6 m8 m8 m10 m10 m10 m10 m10 m10 m12 m12 k 92 92 92 92 92 92 138 138 l 20.5 20.5 20 15 15 16 16 37 37 37 37 37 37 67 67 m 380 380 380 380 380 380 610 610 n 211 211 211 211 211 211 201 201 o 93 93 93 93 93 93 132 132 p 26.5 26.5 26.5 26.5 26.5 26.5 29 29 u 60 60 60 60 60 60 60 60 v 20 20 20 25 25 25 40 40 w 3 3 3 6 6 8 8 8 x 10 10 10 12.5 12.5 12.5 20 20 y 37 37 37 37 37 37 47 47 z ?9 ?9 ?9 ?11 ?11 ?11 ?13.5 ?13.5 -33 -34 -35 -44 filter input/output connector cross sections solid wire 16mm 2 35mm 2 50mm 2 10mm 2 flex wire 10mm 2 25mm 2 50mm 2 6mm 2 awg type wire awg 6 awg 2 awg 1/0 awg 8 recommended torque 1.5 - 1.8nm 4.0 - 4.5nm 7 - 8nm 1.5 - 1.8nm please visit www.schaffner.com to find more details on filter connectors.
|