  embedded power for business-critical continuity nlp110 series single and triple output special features ? provides up to 10.5 a on either 3.3 v or 5 v ? 5.5 x 3.0 inch card and 1.26 inch package (1u applications) ? 3.3 v, 5 v and 12 v triple ? en61000-3-2 compliant ? overvoltage and short circuit protection ? en55022, en55011 conducted emissions level b ? en61000-4-2, -3, -4, -5, -6 immunity compliant ? mounting holes as per nlp65 series, easy upgrade ? available rohs compliant ? 2 year warranty total power: 80 - 110 w input voltage: 90 - 264 vac # of outputs: single, triple safety vde0805/en60950/iec950 file no. 10401-3336-1096 ul1950 file no. e136005 csa c22.2 no. 950 file no. lr41062 rev.04.05.08 nlp110 series 1 of 4 electrical specifications input input voltage range universal input, 90-264 vac (see note 6) input frequency range 47-63 hz input current (cold start) 120 vac 18 a max. 230 vac 35 a max. safety ground leakage current 120 vac, 60 hz 0.45 ma 230 vac, 50 hz .75 ma input current 120 vac @ 80 w 0.9 a rms 120 vac @ 110 w 1.3 a rms 230 vac @ 80 w .48 a rms 230 vac @ 110 w 0.7 a rms input fuse ul/iec127 f3.15 a h, 250 vac output total regulation (line and load) main output 2.0% auxiliary outputs 5.0% rise time at turn-on 1.0 s, max transient response main output 5.0% or 250 mv 75% to 100% max. dev., 1ms max. step at 0.1 a/s recovery to 1% temperature coefficient 0.02%/c overvoltage protection main outputs 125%, 10% short circuit protection cyclic operation continuous minimum output current single and multiple see table
rev.04.05.08 nlp110 series 2 of 4 embedded power for business-critical continuity thermal performance operating ambient, 0 c to +50 c (see derating curve) non-operating -40 c to +85 c 50 c to 70 c ambient, derate to convection cooled 50% load 0 c to 50 c, ambient, 80 w convection cooled 0 c to 50 c ambient, 110 w 150 lfm forced air peak (0 c to +50 c, 60 s) (see note 3) relative humidity non-condensing 5% to 95% rh altitude operating 10,000 feet max non-operating 30,000 feet max vibration (see note 5) 5-500 hz 2.4 g rms peak shock per mil-std-810e 516.4 part iv environmental specifications general specifications hold-up time 120 vac, 60 hz 16.7 ms @ 110 w efficiency 120 vac, 80 w (-9605j) 75% min. isolation voltage input/output 3000 vac input/chassis 1500 vac approvals and standards pending en60950, vde0805, iec950, ul1950, csa c22.2 no. 950 weight 283 g (10 oz) mtbf demonstrated mil-hdbk-217f 220,000 hours min emc charateristics (12) conducted emissions en55022, fcc part 15 level b radiated emissions en55022, fcc part 15 level a harmonic current emission correction en61000-3-2 compliant esd air en61000-4-2 level 3 esd contact en61000-4-2 level 3 surge en61000-4-5 level 3 fast transients en61000-4-4 level 3 radiated immunity en61000-4-3 level 3 conducted immunity en61000-4-6 level 3 all specifications are typical at nominal input, full load at 25 c unless otherwise stated. derating curve output power (watts) 0c 10c 20c 30c 40c 50c 60c 70c 40w 80w 110w 150 lfm forced air cooling 55w natural convection cooling
rev.04.05.08 nlp110 series 3 of 4 embedded power for business-critical continuity notes 1 free air convection. multiple output units: maximum continuous output power not to exceed 80 w. for -9693j; i 3.3 v = 13 a max.; i 5.0 v = 13 a max.; i 3.3 v +i 5.0 v 2 16 a. for -9694j; i 3.3 v = 13 a max.; i 2.5 v = 13 a max.; i 3.3 v +i 2.5 v 2 16 a for -9695j; i 3.3 v = 13 a max.; i 12 v = 6.5 a max.; i 3.3 v +i 12 v 2 16 a. for -9608j; i 5.0 v = 13 a max.; i 12 v = 6.5 a max.; i 5.0 v +i 12 v 2 16 a. single output units: maximum continuous output power not to exceed; 75 w on -9605j; 76.8 w on -9612j,-9624j, and -9617j. 2 150 lfm forced air cooling from l4 side. multiple output units: maximum continuous output power not to exceed 105 w. for -9693j; i 3.3 v = 16 a max.; i 5.0 v = 16 a max.; i 3.3 v +i 5.0 v 2 20 a. for -9694j; i 3.3 v = 16 a max.; i 2.5 v = 16 a max.; i 3.3 v +i 2.5 v 2 20 a for -9695j; i 3.3 v = 16 a max.; i 12 v = 8.5 a max.; i 3.3 v +i 12 v 2 20 a. for -9608j; i 5.0 v = 16 a max.; i 12 v = 8.5 a max.; i 5.0 v +i 12 v 2 20 a. single output units: maximum continuous output power not to exceed 110 w for all models. 3 300 lfm forced air cooling from l4 side. multiple output units: maximum continuous output power not to exceed 110 w. for -9693j; i 3.3 v = 20 a max.; i 5.0 v = 18 a max.; i 3.3 v +i 5.0 v 2 22 a. for -9694j; i 3.3 v = 20 a max.; i 2.5 v = 20 a max.; i 3.3 v +i 2.5 v 2 22 a for -9695j; i 3.3 v = 20 a max.; i 12 v = 8.5 a max.; i 3.3 v +i 12 v 2 22 a. for -9608j; i 5.0 v = 20 a max.; i 12 v = 8.5 a max.; i 5.0 v +i 12 v 2 22 a. single output units: maximum continuous output power not to exceed 110 w for all models. 4 peak output current lasting less than 30 seconds with duty cycle less than 5%. during peak loading, output voltage may exceed total regulation limits. 5 figure is peak-to-peak for convection power rating. output noise measurements are made across a 20 mhz bandwidth using a 6 twisted pair, terminated with a 10 f electrolytic capacitor and a 0.1 f ceramic capacitor. 6 minimum load required for correct start-up and operation on single outputs and on main output of multiple versions. failure to observe minimum load on main output will not allow the supply to start-up correctly. some electronic test loads have a large delay time before they start drawing current even though the voltage from the supply is present. during this time delay, there is no load on the output and as a result, the supply cannot start-up properly and maintain its correct output voltage. in these instances, a dummy resistive load across the output may be necessary to load the output of the supply until the test load can function correctly and draw the intended minimum load. minimum load required on auxiliary outputs to maintain regulation. 7 for models NLP110-9608J and nlp110-9695j, the 12 v output is floating. for -12 v output, pin 11 on j2 has to be connected to return making pin 12 the -12 v output 8 three orthogonal axes, random vibration 10 minutes for each axes, 2.4 g rms 5 hz to 500 hz. 9 for optimum reliability, no part of the heatsink should exceed 110 ?c, and no semiconductor case temperature should exceed 120 ?c. 10 caution: allow a minimum of 1 second after disconnecting line power when making thermal measurements. 11 this product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 12 the emi specifications reference measurements made with the power supply mounted on a grounded metal sheet extending 1 inch beyond each edge, using an unshielded cable. no external filtering required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. a line choke, (ac input cords looped twice through an emi suppression toroid) was used during radiated emissions testing. considerable radiated testing in 1u six-sided boxes has shown that units can meet level b in typical systems. application support is available from the factory to assist with emi compliance. 13 all models require a minimum mounting stand-off of 6.35 mm (0.25 inches) in the end use product. 14 the j suffix indicates that these parts are pb-free (rohs 6/6) compliant. 15 notice: some models do not support all options. please contact your local emerson network power representative or use the on-line model number search tool at http://www.powerconversion.com/products. ordering information output v olta g e min (6) ma x (1) 1 50 lf m (2) 300 lf m ( 3 ) p ea k (4) r ipple ( 5 ) t otal r e g ulation mo d el n u mb ers (7, 14, 1 5 ) +5 v 0.5 a 15 a 22 a 22 a 22 a 50 mv 2.0% nlp110-9605j +12 v 0.3 a 6.4 a 9.2 a 9.2 a 11.5 a 120 mv 2.0% nlp110-9612j +48 v 0 a 1.6 a 2.3 a 2.3 a 2.5 a 240 mv 2.0% nlp110-9617j +24 v 0.2 a 3.2 a 4.6 a 4.6 a 6.0 a 240 mv 2.0% nlp110-9624j +5 v (a) 0.5 a 13 a 16 a 18 a 18 a 50 mv 2.0% nlp110-9693j +3.3 v (b) 0.2 a 13 a 16 a 20 a 20 a 50 mv 2.0% +12 v 0 a 0.65 a 1.0 a 1 a 1 a 120 mv 5.0% +3.3 v (a) 0.5 a 13 a 16 a 20 a 22 a 50 mv 2.0% nlp110-9694j +2.5 v (b) 0.1 a 13 a 16 a 20 a 22 a 50 mv 2.0% +12 v 0 a 0.65 a 1 a 1 a 1 a 120 mv 5.0% +12 v (a) 0.2 a 6.5 a 8.5 a 8.5 a 10 a 1200 mv 2.0% nlp110-9695j +3.3 v (b) 0.5 a 13 a 16 a 20 a 22 a 50 mv 2.0% -12 v 0 a 0.65 a 1 a 1 a 1 a 120 mv 5.0% +12 v (a) 0.2 a 6.5 a 8.5 a 8.5 a 10 a 120 mv 2.0% NLP110-9608J +5 v (b) 0.2 a 13 a 16 a 18 a 22 a 50 mv 2.0% -12 v 0 a 0.65 a 1 a 1 a 1 a 120 mv 5.0%
embedded power for business-critical continuity rev.04.05.08 nlp110 series 4 of 4 0.23 (5.842) 6.50 (165.10) 1 t1 (ref.) j4 j1 6.050 (153.670) 2.550 (64.770) all dimensions in inches (mm) j2 j3 1 1 2 12 3.00 (76.20 f1 j5 2 1 0.23 (5.842) ! 3 maximum component height is 1.26 (32.00) r eco mm en d e d d irection for force d air relati v e to po w er suppl y orientation sho w n b elo w. 1 optimum. 2 very good. 3 good. 4 not recommended. 2 3 4 1 input an d output connectors matin g connectors a c ( j 1) connector t y pe molex 26-60-4030 or equivalent. a c ( j 1) m atin g connector t y pe molex 09-50-3031 or equivalent with molex 08-50-0105 or equivalent crimp terminals. d c ( j 2) connector t y pe 12 position molex spox type 26-48 1125 or equivalent. d c ( j 2) m atin g connector t y pe molex spox type 26-03-3121 and contact 08-52-0113. sense ( j3 ) connector t y pe molex 22-23-2021 or equivalent. sense ( j3 ) m atin g connector t y pe molex 22-01-3027 and contact 08-50-0113. earth ( j 4) connector t y pe male 0.250 quick disconnect. earth ( j 4) m atin g connector t y pe molex 90028. sense ( j5 ) connector t y pe leoco 2421p02h000. sense ( j5 ) m atin g connector t y pe leoco 2420s020000 and contact 2453tpb00v1. americas 5810 van allen way carlsbad, ca 92008 usa telephone: +1 (760) 930 4600 facsimile: +1 (760) 930 0698 europe (uk) waterfront business park merry hill, dudley west midlands, dy5 1lx united kingdom telephone: +44 (0) 1384 842 211 facsimile: +44 (0) 1384 843 355 asia (hk) 14/f, lu plaza 2 wing yip street kwun tong, kowloon hong kong telephone: +852 2176 3333 facsimile: +852 2176 3888 for global contact, visit: www.powerconversion.com technicalsupport@ powerconversion.com while every precaution has been taken to ensure accuracy and completeness in this literature, emerson network power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. emerson network power and the emerson network power logo are trademarks and service marks of emerson electric co. ?2008 emerson electric co. emersonnetworkpower. com embedded computing embedded power monitoring outside plant power switching & controls precision cooling racks & integrated cabinets services surge protection emerson network power. the global leader in enabling business-critical continuity. ac power connectivity dc power input pin connections j1 pin 1 ac neutral pin 2 no connection pin 3 ac line j3 pin 1 v (a) sense + pin 2 v (a) sense - j4 pin 1 safety earth j5 pin 1 v (b) sense + pin 2 v (b) sense - output pin connections j2 single triple pin 1 no connection v (b) pin 2 no connection v (b) pin 3 no connection v (b) pin 4 return return pin 5 return return pin 6 return return pin 7 return return pin 8 v (a) v (a) pin 9 v (a) v (a) pin 10 v (a) v (a) pin 11 no connection v (c) pin 12 no connection v (c) return (7)


▲Up To Search▲   

 
Price & Availability of NLP110-9608J

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X