  150 pcb power relay ?g4a miniature single-pole relay with 80-a surge current and 20-a switching current rohs compliant. ideal for motor switching. miniature, relay with high switching power and long endurance. creepage distance conforms to ul, csa and en standards. highly noise-resistive insulation materials employed. standard model available with flux protection construction.   vde rated coil voltage note: when ordering, add the rated coil voltage to the model number. example: g4a-1a-e 12 vdc g4a- - vdc 1 2 3 4 5 rated voltage 5 vdc 12 vdc 24 vdc rated current 180 ma 75 ma 37.5 ma coil resistance 27.8 ? 160 ? 640 ? 0.8 h 3.5 h 1.1 h 4.8 h must operate voltage 70% of rated voltage max. must release voltage 10% of rated voltage min. max. permissible voltage 160% of rated voltage at (23? power consumption approx. 0.9 w note: 1. the rated current and coil resistance are measured at a coil temperature of 23?c with a tolerance of ?0%. 2. operating characteristics are measured at a coil temperature of 23?c. 3. max. permissible voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. specifications coil rating coil inductance armature off (ref. value) armature on ordering information classification contact form model #250 tab terminals/pcb coil terminals spst-no g4a-1a-e pcb terminals/pcb coil terminals g4a-1a-pe model number legend 1. number of poles 1: 1 pole 2. contact form a: spst-no 3. terminals none: #250 tab/pcb coil terminals p: straight pcb/pcb terminals 4. special function e: for long endurance 5. rated coil voltage 5, 12, 24 vdc
151 pcb power relay ?g4a characteristics contact resistance 100 m ? max. operate time 20 ms max. release time 10 ms max. max. operating frequency mechanical: 18,000 operations/hr insulation resistance 1000 m ? max. (at 500 vdc) insulation resistance 100 m ? max. (at 500 vdc) dielectric strength 4,500 vac 50/60 hz for 1 min between coil and contacts 1,000 vac 50/60 hz for 1 min between contacts of same polarity shock resistance destruction: 1,000 m/s 2 malfunction: 200 m/s 2 v ibration resistance destruction: 10 to 55 to 10 hz, 0.75-mm single amplitude (1.5-mm double amplitude) malfunction: 10 to 55 to 10 hz, 0.75-mm single amplitude (1.5-mm double amplitude) endurance mechanical: 2,000,000 operations min. (at 18,000 operations/hr) motor load: 100,000 operations min. (on/off: 1.5 s) inverter load: 30,000 operations min. (on: 3 s, off: 5 s) ambient temperature operating: -20? to 60? (with no icing) ambient humidity operating: 5% to 85% w eight approx. 25 g note: the data shown above are initial values. contact ratings rated load 20 a at 250 vac rated carry current 20 a max. switching voltage 250 vac max. switching current 20 a max. switching power 5,000 va failure rate (ref. value) 1 00 ma at 5 vdc note: p level: 60 = 0.1 x 10 -6 /operation (with an operating frequency of 120 operations/min). endurance with motor load load conditions switching frequency electrical endurance 250 vac: on: 1.5 s 200,000 operations inrush current: 80 a, 0.3 s (cos? 0.7) off: 1.5 s break current: 20 a (cos?= 0.9) with overload load conditions switching frequency electrical endurance 250 vac: on: 1.5 s 1,500 operations inrush current: 80 a (cos? 0.7) off: 99 s break current: 80 a (cosf? 0.7) with inverter load load conditions switching frequency electrical endurance 100 vac: on: 3 s 30,000 operations inrush current: 200 a (0-p) off: 5 s break current: 20 a power relays
152 pcb power relay ?g4a engineering data maximum switching power endurance switching current (a) endurance (x10 operations) 3 switching voltage (v) switching current (a) ac resistive load ac inductive load cos = 0.4 250-vac resistive load 250-vac inductive load cos = 0.4 5,000 3,000 1,000 700 500 300 100 70 50 din en 61810-1/en 60255-23 (vde reg. no. 6673) model coil ratings contact ratings g4a-1a 5 to 48 vdc 20a, 250vac
153 pcb power relay ?g4a precautions mounting when mounting two or more relays side by side, provide a minimum space of 3 mm between relays. te rminal connection the terminals fit faston receptacle 250 and are suitable for positive-lock mounting. do not apply excessive force on the terminals when mounting or dismounting the relay. the following positive-lock connectors made by amp are recommended. t ype receptacle terminals positive housing #250 terminals (width: 6.35 mm) amp 170333-1 (170327-1) amp 172076-1 natural color amp 170334-1 (170328-1) amp 172076-4 yellow amp 170335-1 (170329-1) amp 172076-5 green amp 172076-6 blue note: the numbers shown in parentheses are for air-feeding. dimensions note: all units are in millimeters unless otherwise indicated; dimensions shown in parentheses are in inches. t erminal arrangement /internal connections g4a-1a-e mounting holes (bottom view) 30.5 max. (30.1)* 16 max. (15.7)* 23.5 max. (23.3)* (top view) (bottom view) t ab terminal pcb terminal f our, 1.8 +0.1 0 dia. f our, 1.8 +0.1 0 dia. 16 max. (15.7)* 26.8 max. (26.5)* 30.5 max. (30.1)* g4a-1a-pe t erminal arrangement /internal connections (bottom view) mounting holes (bottom view) *average value *average value power relays


▲Up To Search▲   

 
Price & Availability of G4A-1A-PE5VDC

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X