  engineering data sheet tdh-1610 on release fixed period 1pno (sso) application note: 101 applicable sockets: sm-1000-003 features l small size and weight l high-reliability design l hermetically sealed l high transient immunity l qualified to mil-prf-83726/25 l compatible with m12883/52 & /53 socket module and track mount principle technical characteristics enclosure:hermetic sealed per mil-std-883, method 1014 condition b,c yes finish: per mil-t-10727 tin plate terminals: gold plate per mil-g-45204 type ii, class 2, grade c plug-in weight 0.56 ounce max. description the tdh-1610 time delay relays have been designed with thick film hybrid microelectronics timing circuits and are packaged in a hermetically sealed military style enclosure. the tdh-1610 series are qualified to mil-prf- 83726/25 and designed to withstand severe environmental conditions encountered in military/aerospace applications. these relays are suited for use in power control, communication circuits and many other applications where power switching and high reliability are required over a wide temperature range. featuring leach ? power and control solutions www.esterline.com americas 6900 orangethorpe ave. p.o. box 5032 buena park, ca 90622 . . tel: (01) 714-736-7599 fax: (01) 714-670-1145 europe 2 rue goethe 57430 sarralbe france . . tel: (33) 3 87 97 31 01 fax: (33) 3 87 97 96 86 asia units 602-603 6/f lakeside 1 no.8 science park west avenue phase two, hong kong science park pak shek kok, tai po, n.t. hong kong tel: (852) 2 191 3830 fax: (852) 2 389 5803 data sheets are for initial product selection and comparison. contact esterline power systems prior to choosing a component. date of issue: 3/06 - 73 - page 1 of 3
electrical specification tdh-1610 input (control) parameters timing: a. operation, time delay on b. method c. range d. accuracy release fixed period 0.05 to 500 seconds 10% [1] recycle time 10 ms, min [5] operations: (x1-x2) a. input & control voltage b. operating current 20-30 vdc 10 ma, max @ +25 c transients: mil-std-704a, limit 1 a. spike susceptibility b. positive, transients c. self-generated spikes +80 volts max 600 volts max none electromagnetic interference per mil-std-461a class 1d [3] power loss 1 ms [2] output (load) parameters contact form contact rating voltage drop, maximum leakage current, maximum: a. at 28 vdc and 25 c d. at 28 vdc and 125 c spst 150 ma 2 vdc 1 microampere 10 microamperes dielectric strength: a. @ sea level, 60 hz b. @ 80,000 ft., 60 hz 1000 vrms [4] 350 vrms insulation resistance @ 500 vdc 1000 m w [4] general characteristics ambient temperatures range: a. operating b. non-operating -55 to +125 c -55 to +125 c vibration: a. sinusoidal 10-55 hz 0.06" da 55-500 hz 10 g 500-3000 hz 20 g b. random: mil-std-810 0.2 g 2 /hz shock, 0.5 ms, 1/2 sine, 3 axis 1,100 g acceleration, in any axis 100 g life at rated resistive load; minimum 1,000,000 operations numbering system tdh-1610 - 1001 w m83726/24 - 1001 w | | | | | | | 1 3 4 1 2 3 4 1. model number or basic "mil-prf" series number. 2. military "slash" number. 3. timing range, fixed: 100 milliseconds to 500 seconds. (see note 6). 4. quality level (see note 7). date of issue: 3/06 - 74 - page 2 of 3
mechanical specifications tdh-1610 notes [1] the accuracy specification applies for any combination of operating temperature and voltage. [2] the accuracy will not be affected by power interruptions up to 1 millisecond, spaced at least 10 milliseconds apart. transient and power loss specifications are based on a maximum duty cycle of 1/50. [3] emi test limits will not be exceeded during the timing interval or when continuously energized under steady state conditions, per paragraph 3.23, mil-prf-83726c. [4] terminals x1, x2, a1, b1 and a3 must be connected together during the test. dielectric withstanding voltage and insulation resistance are measured at sea level between all mutually insulated terminals and between all terminals and case. [5] recycle time is defined as the minimum time control power must be removed from terminal b1 to assure that a new cycle can be completed within the specified timing tolerance. [6] a four digit number defines the time delay in seconds (or milliseconds). the first three digits are significant figures, used to define the specific time delay. the fourth digit represents the number of zeros to follow the first three digits. examples: - 1001 = 1 second (1,000 milliseconds) - 2502 = 25 seconds (25,000 milliseconds) - 5000 = 0.5 seconds (500 milliseconds) [7] quality level as specified in mil-r-83726, paragraph 3.1.1, 3.1.2 and 3.1.3. d a t e o f i s s u e : 3 / 0 6 - 7 5 - p a g e 3 o f 3 c l m i l i t a r y p a r t n u m b e r & d a t a s e r i a l n u m b e r . 6 4 0 . 1 7 0 . 2 0 0 m a x 8 p l a c e s . 0 5 0 . 0 0 1 d i a p o l a r i z i n g p i n . 8 1 0 m a x . 0 8 0 . 0 0 5 2 p l a c e s . 1 5 8 . 0 0 3 f r o m f a c e o f h e a d e r 2 p l a c e s n a m e p l a t e ( f a r s i d e ) c i r c u i t d i a g r a m ( n e a r s i d e ) . 0 4 0 . 0 0 1 d i a , 8 p i n s d a t e c o d e ( n e a r s i d e ) f i n i s h : p a r a 3 . 4 . 2 . . 0 5 5 . 0 0 5 . 4 5 0 . 3 0 0 . 1 5 0 2 p l a c e s . 1 8 . 0 7 . 1 5 . 1 3 c o n t r a s t i n g b e a d . 1 1 0 . 0 0 5 2 p l a c e s . 0 1 0 - . 0 1 5 r 4 p l a c e s d i m e n s i o n s a r e s h o w n i n i n c h e s . . 4 1 0 m a x t d f i x e d t i m e d e l a y l o a d c o m m o n ( - ) 2 0 - 3 2 v d c ( + ) b 1 x 2 a 1 x 1 a 3 c o n t r o l 2 0 - 3 2 v d c ( + ) c o n t r a s t i n g b e a d l 2 0 - 3 2 v d c 2 0 - 3 2 v d c 0 v d c 0 v d c x 1 - x 2 ( b 1 - x 2 ) i n p u t v o l t a g e c o n t r o l d e - e n e r g i z e d t i m e d e l a y t i m e d e l a y o n r e l e a s e e n e r g i z e d n o t e 6
application notes n101 derating of contacts for dc voltages above nominal rating to establish a standard for the derating of relay contacts is, at best, a subjective practice. limitations are governed by the type of relay, contact gap, maximum voltage capabilities of the relay contact system, and the contact material. the most common method is to derate the contacts by use of the power formula, using the known current and voltage. this method is valid only for resistive loads, and is an approximation only; keeping in mind the limitations mentioned above. power = ie (current x voltage) i 2 e 2 = 2/3 i 1 e 1 example: a designer is working with a 55 volt dc system and has a relay rated at 10 amps resistive at 28 volts dc. what is the maximum current that can be switched at 55 vdc. i 1 = 10 amperes e 1 = 28 vdc e 2 = 55 vdc i 2 = ? (current ratings at 55 vdc resistive) i 2 e 2 = 2 i 1 e 1 /3 i 2 = 2 i 1 e 1 /e 2 3 = 2 (10 x 28)/55 x 3 = 560/165 i 2 = 3.4 amperes at 55vdc in addition, the user should always be concerned about the following: 1. derating contacts that are rated for less than 10 amperes at nominal voltage. 2. derating contacts for use in system voltages above 130 volts dc date of issue: 6/00 - 14 - page 1 of 1
engineering data sheet sm-1000-003 track mount relay socket 5 amp applicable track: mt-3000-03 basic socket series designation for: series x (track mount) series td-1609, td-1610 (track mount) qualified to: mil-dtl-12883/52-001 general characteristics 1. supplied with no. 20 contacts and no. 20 crimp. 2. standard tolerances .xx .01; xxx .005. 3. weight .016 lb. max. 4. used in conjunction with mt-3000-003 featuring leach ? power and control solutions www.esterline.com americas 6900 orangethorpe ave. p.o. box 5032 buena park, ca 90622 . . tel: (01) 714-736-7599 fax: (01) 714-670-1145 europe 2 rue goethe 57430 sarralbe france . . tel: (33) 3 87 97 31 01 fax: (33) 3 87 97 96 86 asia units 602-603 6/f lakeside 1 no.8 science park west avenue phase two, hong kong science park pak shek kok, tai po, n.t. hong kong tel: (852) 2 191 3830 fax: (852) 2 389 5803 data sheets are for initial product selection and comparison. contact esterline power systems prior to choosing a component. date of issue: 8/09 - 5 - page 1 of 1
engineering data sheet mt-3000-003 relay socket track basic socket series designation for: series sm sockets (track mount) meets the requirements of: mil-dtl-12883 general characteristics used in conjunction with sm-1000-003, sm-1001-003 and sm-1002-003 track mount relay sockets. standard tolerances .xx .01; xxx .005. weight .056 lb. max. m12883/53-001.....[mt-3000-003] featuring leach ? power and control solutions www.esterline.com americas 6900 orangethorpe ave. p.o. box 5032 buena park, ca 90622 . . tel: (01) 714-736-7599 fax: (01) 714-670-1145 europe 2 rue goethe 57430 sarralbe france . . tel: (33) 3 87 97 31 01 fax: (33) 3 87 97 96 86 asia units 602-603 6/f lakeside 1 no.8 science park west avenue phase two, hong kong science park pak shek kok, tai po, n.t. hong kong tel: (852) 2 191 3830 fax: (852) 2 389 5803 data sheets are for initial product selection and comparison. contact esterline power systems prior to choosing a component. date of issue: 8/09 - 40 - page 1 of 1


▲Up To Search▲   

 
Price & Availability of TDH-1610-1001W

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X