66 cardinal components, inc., 155 rt. 46 w, wayne, nj. 07470 tel: (973)785-1333 fax: (973)785-0053 http://www.cardinalxtal.com e-mail: cardinal@cardinalxtal.com 66 cardinal components cardinal components . thru hole tcxo 8.0 mm height tight stability availability sinewave output cc180 specifications: frequency range: 1.000 mhz to 35.000 mhz available stability options: 5.0 ppm 4.5 ppm 4.0 ppm 3.5 ppm 3.0 ppm 2.5 ppm 2.0 ppm 1.5 ppm output series: clipped sine input voltage: +5.0 vdc 5% operating temperature 0 c to +50 c range options: -10 c to +60 c -10 c to +70 c -20 c to +70 c -30 c to +60 c -30 c to +70 c -30 c to +75 c -40 c to +80 c output voltage: 1.0 volt peak to peak minimum frequency trim range 3.0 ppm minimum with externally adjustable trimmer: output load: 20k ohm parallel with 5 pf maximum input current: 3 ma maximum frequency 1 ppm/yr aging at +25 c: storage temperature: -40 c to +80 c part numbering example: cc180 l - a2 b2 - 22.5792 series series cc180 cc180 operating temp. a2 = -10 c ~+60 c a3 = -30 c ~+75 c a5 = -20 c ~+70 c a9 = 0 c ~+50 c aa = -10 c ~+70 c ab = -30 c ~+70 c ac = -30 c ~+60 c ae = -40 c ~+80 c a2 stability b1 = 5.0 ppm b2 = 3.0 ppm b3 = 2.5 ppm b4 = 2.0 ppm b5 = 1.5 ppm b9 = 4.0 ppm bb = 4.5 ppm bf = 3.5 ppm b2 frequency 22.5792 blank = 5v l = 3.3v l voltage cc180
|