h h w w s s s s e e r r i i e e s s 1 specifications ? lifetime warranty ?ul508 approved ? semi f47 compliant (high line ac) ? universal input (85 - 265vac) ? high efficiency ? rohs compliant design key market segments & applications factory automation process control, nc-machining, automotive, packaging equipment, materials handling, chemical processing, robots test & measurement burn-in & test, automated automated service test, instrumentation, measurement, detection hws features and benefits features benefits ? lifetime warranty ? high efficiency ? wide range ac input ? lower cost of ownership ? easier system cooling ? supports global use hws series single output industrial power supplies models items hws15 hws30 hws50 hws100 hws150 input v oltage range 85 - 265v ac (47 - 63hz) or 120 - 370vdc input current (t yp) (1) a 0.4 / 0.2 0.8 / 0.4 0.7 / 0.35 1.3 / 0.65 1.9 / 0.95 inrush current 100/200vac a 14 / 28 power factor meets en61000-3-2 temperature coefficient <0.02%/ o c overcurrent protection - >104% overvoltage p rotection v yes (see page 2) hold up time (t yp) ms 20 l eakage current (max) ma <0.5ma (t yp 0.3ma at 100v ac, 0.5ma at 230vac) remote sense no ye s indicator green led = on operating t emp. (no cover) -10c to +70c, derate linearly to 20% load from 50c to 70c storage t emperature -30 to +85c humidity (non condensing) operating: 30 - 90%rh, non operating 10 - 95%rh cooling convection withstand voltage input to ground 2kvac, input to output 3kvac, output to ground 500vac for 1 min. isolation resistance >100m at 25c & 70%rh , output to ground 500vdc vibration (non operating) 10 - 55hz (1 minute sweep), 19.6m/s 2 constant x , y, z 1 hour shock < 196.1m/s 2 safety agency approvals -ul60950-1, csa60950-1, en60950-1, en50178, built to meet ul508 ce mark line dip complies with semi f47 (200v a c line only) conducted & radiated emi en55011 / en55022-b, fcc-b, vcci-b immunity iec61000-4-2(level 2,3), -3(level 3), -4(level 4), -5(level 3,4), -6(level 3), -8(level4, -11 weight (typ) g 180 220 280 450 500 size (wxhxd) mm 26.5x82x80 26.5x82x95 26.5x82x120 28x82x160 37x82x160 w arranty lifetime warranty (see lambda terms & conditions) notes: (1) 100/200vac see website for hws/me medical en/ul60601-1 approved models and hws/hd heavy duty / harsh environment models with -40 degree c startup in no vati on s oluti ons suppo rt re liab ility
h h w w s s s s e e r r i i e e s s 2 1 .2m/s f orced air 5 0 55c 60c 65c 70 model selector options suffix description max load line ripple over eff. adjust curr. reg reg noise voltage typ % model voltage range a mv mv mv v 100/200 vac blank screw terminals, no cover /a screw terminals, cover /r remote on/off (50-150w only) example: hws50-24/ra hws15 outline drawing full size drawings and more information available at www .lambda- europe.com/hws hws15-3/a 3.3v 2.97 - 3.96 3 40 20 120 4.13-4.95 68/71 h ws30-3/a 3.3v 2.97 - 3.96 6 40 20 120 4.13-4.95 70/73 hws50-3/a 3.3v 2.97 - 3.96 10 40 20 120 4.13-4.95 76/78 h ws100-3/a 3.3v 2.97 - 3.96 20 40 20 120 4.13-4.95 78/81 hws150-3/a 3.3v 2.97 - 3.96 30 40 20 120 4.13-4.95 78/81 hws15-5/a 5v 4.0 - 6.0 3 40 20 120 6.25-7.25 77/79 hws30-5/a 5v 4.0 - 6.0 6 40 20 120 6.25-7.25 77/80 h ws50-5/a 5v 4.0 - 6.0 10 40 20 120 6.25-7.25 82/83 hws100-5/a 5v 4.0 - 6.0 20 40 20 120 6.25-7.25 83/86 hws150-5/a 5v 4.0 - 6.0 30 40 20 120 6.25-7.25 83/86 hws15-12/a 12v 9.6 - 14.4 1.3 96 48 150 15-17.4 80/81 hws30-12/a 12v 9.6 - 14.4 2.5 96 48 150 15-17.4 81/83 hws50-12/a 12v 9.6 - 14.4 4.3 96 48 150 15-17.4 81/83 hws100-12/a 12v 9.6 - 14.4 8.5 96 48 150 15-17.4 83/86 hws150-12/a 12v 9.6 - 14.4 13 96 48 150 15-17.4 83/86 hws15-15/a 15v 12.0 - 18.0 1 120 60 150 18.8-21.8 80/81 hws30-15/a 15v 12.0 - 18.0 2 120 60 150 18.8-21.8 81/83 hws50-15/a 15v 12.0 - 18.0 3.5 120 60 150 18.8-21.8 81/83 hws100-15/a 15v 12.0 - 18.0 7 120 60 150 18.8-21.8 83/86 hws150-15/a 15v 12.0 - 18.0 10 120 60 150 18.8-21.8 83/86 hws15-24/a 24v 19.2 - 28.8 0.65 192 96 200 30-34.8 82/83 hws30-24/a 24v 19.2 - 28.8 1.3 192 96 200 30-34.8 83/86 hws50-24/a 24v 19.2 - 28.8 2.2 192 96 200 30-34.8 82/84 hws100-24/a 24v 19.2 - 28.8 4.5 192 96 200 30-34.8 84/87 hws150-24/a 24v 19.2 - 28.8 6.5 192 96 200 30-34.8 85/88 hws15-48/a 48v 38.4 - 52.8 0.33 384 192 200 55.2-64.8 80/80 hws30-48/a 48v 38.4 - 52.8 0.65 384 192 200 55.2-64.8 82/83 hws50-48/a 48v 38.4 - 52.8 1.1 384 192 200 55.2-64.8 83/85 hws100-48/a 48v 38.4 - 52.8 2.1 384 192 200 55.2-64.8 84/87 hws150-48/a 48v 38.4 - 52.8 3.3 384 192 200 55.2-64.8 85/88
h h w w s s s s e e r r i i e e s s 3 hws30 outline drawing hws50 outline drawing hws100 outline drawing hws150 outline drawing note: all fixing holes m3 tapped max. depth 6mm
d d l l p p s s e e r r i i e e s s 4 h h w w s s s s e e r r i i e e s s 4 hws series (15-150w) iss4 jan08 lambda europe france lambda sas telephone: +33 (0) 1 60 12 71 65 zac des delaches, bp1077 - gometz le chatel facsimile: +33 (0) 1 60 12 71 66 91940 les ulis web: www.lambda-f.com germany lambda gmbh telephone: +49 (0) 78 41 666 0 karl-bold-stra? 40 facsimile: +49 (0) 78 41 5000 d -77855 achern web: www.lambda-germany.com israel nemic lambda ltd telephone: +972 (0) 3 902 4333 kibbutz givat facsimile: +972 (0) 3 902 4777 hashlosha 48800 web: www.nemic.co.il italy lambda s.r.l. telephone: +39 (0) 02 61 29 38 63 v ia dei lavoratori 128/130, facsimile: +39 (0) 02 61 29 09 00 20092, cinisello balsamo (mi) web: www.lambda-italy.com sweden lambda scandinavia telephone: +46 (0) 8 598 94 090 po box 546, rallar v?gen 41 facsimile: +46 (0) 8 540 66 096 se-184 25. akersberga web: www.lambda-scandinavia.com uk lambda uk telephone: +44 (0) 1271 856666 kingsley a venue facsimile: +44 (0) 1271 864894 ilfracombe devon ex34 8es w eb: www.lambda-gb.com austria lambda electronics gmbh telephone: +43 (0) 2256 655 84 aredstra? 22 facsimile: +43 (0) 2256 645 12 a-2544 leobersdorf www.lambda-austria.com lambda nor th america lambda asia local distribution visit www .lambdapower .com for a list of lambda of fices and distributors visit www.densei-lambda.com for a list of lambda offices and distributors
|