  panasonic corporation automation controls business unit industrial.panasonic.com/ac/e/ he pv type asctb101e 201208-t ordering information ideal for solar inverter compact size, 1a 35a/48a power relays he relays pv type vde rohs compliant features ?35a/48a current at 250 v ac achieved in compact size (l: 33 w: 38 h: 36.3 mm l: 1.299 w: 1.496 h: 1.429 inch ) due to improved conduction ef?iency, wide terminal blades are used. (for high capacity type) ?contact gap: 2.5 mm (vde0126 compliant) compliant with european photovoltaic standard vde0126 compliant with en61810-1 2.5 kv surge breakdown voltage (between contacts) ?contributes to energy saving in devices thanks to reduced coil hold voltage coil hold voltage can be reduced down to 40% of the nominal coil voltage (ambient temperature 20 c 68 f ). this equals to operating power of approximately 310 mw. *coil hold voltage is the coil voltage after 100 ms following application of the nominal coil voltage. ?high insulation and 10,000 v surge breakdown voltage (between contacts and coil) achieved. ?conforms to various safety standards ul/c-ul and vde typical applications ?photovoltaic power generation systems (solar inverter) contact arrangement 1a: 1 form a (single side stable type) pick-up voltage n: 70% of nominal voltage he 1a n p dc terminals p: pc board terminal type coil voltage (dc) 6, 9, 12, 24v type, contact material and switching capacity y5: h18: pv type, agni type (1 form a 48a high capacity) pv type, agsno 2 type (1 form a 35a standard)
panasonic corporation automation controls business unit industrial.panasonic.com/ac/e/ he pv type asctb101e 201208-t types standard packing: carton: 20 pcs.; case: 100 pcs. *standard 6v, 12v and 24v dc type: certi?d by ul/c-ul (standard 9v type: certi?d by ul/c-ul and vde) rating 1. coil data 2. speci?ations notes: *1. this value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. wave is standard shock voltage of 1.2 50 s according to jec-212-1981 *3. coil hold voltage is the coil voltage after 100 ms following application of the nominal coil voltage. *4. the upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. refer to usage, transport and storage conditions in notes. *5. release time will lengthen if a diode, etc., is connected in parallel to the coil. be sure to verify operation under actual conditions. nominal coil voltage standard type* high capacity type part no. part no. 6v dc he1an-p-dc6v-h18 he1an-p-dc6v-y5 9v dc he1an-p-dc9v-h18 he1an-p-dc9v-y5 12v dc he1an-p-dc12v-h18 he1an-p-dc12v-y5 24v dc he1an-p-dc24v-h18 he1an-p-dc24v-y5 nominal coil voltage pick-up voltage (at 20 c 68 f ) (initial) drop-out voltage (at 20 c 68 f ) (initial) nominal operating current [ 10%] (at 20 c 68 f ) coil resistance [ 10%] (at 20 c 68 f ) nominal operating power max. applied voltage (at 20 c 68 f ) 6v dc 70%v or less of nominal voltage 10%v or more of nominal voltage 320ma 18.8 ? 1,920mw 110%v of nominal voltage 9v dc 213ma 42.2 ? 12v dc 160ma 75.0 ? 24v dc 80ma 300.0 ? characteristics item speci?ations standard type high capacity type contact arrangement 1 form a contact resistance (initial) max. 100 m ? (by voltage drop 6 v dc 1a) contact material agsno 2 type agni type rating nominal switching capacity 35 a 250 v ac (resistive load) 48 a 250 v ac (resistive load) contact carring power 8,750 va (resistive load) 12,000 va (resistive load) max. switching voltage 250 v ac max. switching current 35 a (ac) 48 a (ac) nominal operating power 1,920 mw min. switching capacity (reference value)* 1 100 ma 5 v dc electrical characteristics insulation resistance (initial) min. 1,000m ? (at 500v dc) measurement at same location as ?reakdown voltage section. breakdown voltage (initial) between open contacts 2,000 vrms for 1 min. (detection current: 10 ma) between contact and coil 5,000 vrms for 1 min. (detection current: 10 ma) surge breakdown voltage* 2 (between contact and coil) (initial) 10,000 v temperature rise max. 60 c 140 f (by resistive method, contact carrying current: 35a, 100%v of nominal coil voltage at 55 c 131 f .) max. 60 c 140 f (by resistive method, contact carrying current: 48a, 100%v of nominal coil voltage at 55 c 131 f .) max. 30 c 86 f (by resistive method, contact carrying current: 35a, 60%v of nominal coil voltage at 85 c 185 f .) max. 30 c 86 f (by resistive method, contact carrying current: 48a, 60%v of nominal coil voltage at 85 c 185 f .) coil hold voltage* 3 40 to 100%v (contact carrying current: 35a, at 20 c 68 f ), 50 to 100%v (contact carrying current: 35a, at 55 c 131 f ), 50 to 60%v (contact carrying current: 35a, at 85 c 185 f ) 40 to 100%v (contact carrying current: 48a, at 20 c 68 f ), 50 to 100%v (contact carrying current: 48a, at 55 c 131 f ), 50 to 60%v (contact carrying current: 48a, at 85 c 185 f ) operate time (at 20 c 68 f ) max. 30 ms (nominal coil voltage, excluding contact bounce time) release time (at 20 c 68 f )* 5 max. 10 ms (nominal coil voltage, excluding contact bounce time) (without diode) mechanical characteristics shock resistance functional min. 98 m/s 2 (half-wave pulse of sine wave: 11 ms; detection time: 10 s.) destructive min. 980 m/s 2 (half-wave pulse of sine wave: 6 ms.) vibration resistance functional 10 to 55 hz at double amplitude of 1.0 mm (detection time: 10 s.) destructive 10 to 55 hz at double amplitude of 1.5 mm expected life mechanical min. 10 6 (at 180 times/min.) electrical resistive load min. 3 10 4 (35 a 250 v ac) (on : off = 1s : 9s) min. 3 10 4 (48 a 250 v ac) (on : off = 1s : 9s) inductive load endurance: 48 a 250 v ac (cos = 0.8), min. 3 10 4 (on : off = 0.1s : 10s) overload: 72 a 250 v ac (cos = 0.8), min. 50 (on : off = 0.1s : 10s) conditions conditions for operation, transport and storage* 4 ambient temperature: ?0 to +55 c ?8 to +131 f (when nominal coil voltage applied) ?0 to +85 c ?8 to +185 f (when applied coil hold voltage is 50% to 60% of nominal coil voltage) humidity: 5 to 85% r.h. (not freezing and condensing at low temperature); atmospheric pressure: 86 to 106 kpa max. operating speed 6 times/min. (at nominal switching capacity on : off = 1s : 9s) unit weight approx. 80 g 2.82 oz
panasonic corporation automation controls business unit industrial.panasonic.com/ac/e/ he pv type asctb101e 201208-t reference data 1.-(1) coil temperature rise (standard type) sample: he1an-p-dc9v-h18, 6 pcs. point measured: coil inside ambient temperature: 25 c 77 f , 60 c 140 f , 85 c 185 f contact carrying current: 35a 1.-(2) coil temperature rise (high capacity type) sample: he1an-p-dc9v-y5, 6 pcs. point measured: coil inside ambient temperature: 25 c 77 f , 60 c 140 f , 85 c 185 f contact carrying current: 48a 0 10 70 60 50 40 30 20 60 70 80 90 100 50 85 c 60 c 25 c coil applied voltage, %v temperature rise, c 0 10 70 60 50 40 30 20 60 70 80 90 100 50 85 c 60 c 25 c coil applied voltage, %v temperature rise, c 2.-(1) electrical life test (standard type, resistive load 250v ac, 35a at 85 c 185 f ) sample: he1an-p-dc9v-h18, 6 pcs. operation frequency: 6 times/min. (on/off = 1.0s : 9.0s) circuit: change of pick-up and drop-out voltage change of contact resistance 250v ac 9v dc contact welding detection and mis- contacting detection circuit 0 0 2 1 4 3 5 6 8 7 9 3 max. min. x pick-up voltage drop-out voltage max. min. x pick-up and drop-out voltage, v no. of operations, 10 4 0 0 20 40 60 80 100 10 30 50 70 90 3 contact resistance, m ? no. of operations, 10 4 max. min. x 2.-(2) electrical life test (high capacity type, resistive load 250v ac, 48a at 85 c 185 f ) sample: he1an-p-dc9v-y5, 6 pcs. operation frequency: 6 times/min. (on/off = 1.0s : 9.0s) circuit: change of pick-up and drop-out voltage change of contact resistance 250v ac 9v dc contact welding detection and mis- contacting detection circuit 0 0 2 1 4 3 5 6 8 7 9 3 max. min. x pick-up voltage drop-out voltage max. min. x pick-up and drop-out voltage, v no. of operations, 10 4 0 0 20 40 60 80 100 10 30 50 70 90 3 contact resistance, m ? no. of operations, 10 4 max. min. x
panasonic corporation automation controls business unit industrial.panasonic.com/ac/e/ he pv type asctb101e 201208-t dimensions (mm inch ) safety standards *only 9v dc type is certi?d. notes for cautions f or us e . certi?ation authority high capacity type c-ul 48 a 277 v ac (at 85 c 185 f ) vde (vde0435) 48 a 250 v ac cos = 0.8 (at 85 c 185 f ) standard type ul, csa 35 a 277 v ac (at 25 c 77 f ) vde (vde0435)* 35 a 250 v ac cos = 1 (at 80 c 176 f ) the cad data of the products with a cad data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ standard type external dimensions general tolerance: 0.3 .012 1.6 .063 1.6 .063 0.8 .031 0.8 .031 4.7 .185 3338.0 1.2991.496 0.5 .020 4 .157 36.3 1.429 pc board pattern (bottom view) tolerance: 0.1 .004 24 32 .945 1.260 4.7 .185 18.6 .732 6-2 dia. hole 6-.079 dia. hole 8.4 .331 cad data schematic (bottom view) single side stable type 14 56 high capacity type external dimensions general tolerance: 0.3 .012 6.3 .248 0.8 .031 1.6 .063 0.8 .031 3338.0 1.2991.496 0.5 .020 4 .157 36.3 1.429 pc board pattern (bottom view) tolerance: 0.1 .004 24 32 .945 1.260 6.5 .256 8.4 .331 1.3 .051 18.6 .732 2-2 dia. hole 2-.079 dia. hole schematic (bottom view) single side stable type 14 56 usage, transport and storage conditions 1) temperature: ?0 to +55 c ?8 to +131 f ?0 to +85 c ?8 to +185 f (when applied coil hold voltage is 50% to 60% of nominal coil voltage) 2) humidity: 5 to 85% rh (avoid freezing and condensation.) the humidity range varies with the temperature. use within the range indicated in the graph below. 3) atmospheric pressure: 86 to 106 kpa temperature and humidity range for usage, transport, and storage ? ?0 to +85 c ?8 to +185 f (when applied coil hold voltage is 50% to 60% of nominal coil voltage) certi?ation this relay is ul/c-ul certi?d. 48 a 277 v ac (high capacity type) 35 a 277 v ac (standard type) this relay is certi?d by vde 48 a 250 v ac cos = 0.8 (high capacity type) 35 a 250 v ac cos = 1 (standard type) 85 5 humidity, %rh tolerance range (avoid condensation when used at temperatures higher than 0 c 32 f ) (avoid freezing when used at temperatures lower than 0 c 32 f ) 550?0 +131+32?8 temperature, c f 85 5 humidity, %rh tolerance range (avoid condensation when used at temperatures higher than 0 c 32 f ) (avoid freezing when used at temperatures lower than 0 c 32 f ) 850?0 +185+32?8 temperature, c f


▲Up To Search▲   

 
Price & Availability of HE-PV

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X