emc filte r FC-LX1D & FC-LX1D2 series 201 4 .02.18- a /2 page 1of 7 mornsun guangzhou science & te chnology co., ltd. reserves the copyright and right of final interpretation emc filter features z compact size z design to suppress the ac power surge to achieve primary protection z ensure the power supply module to meet the requirement of cispr22/en55022 class b z cost-effective z low temperature rise z mounting: pcb mounting, chassis mounting with screw terminals, din-rail mounting rohs this model applies to analog circuit which is noise-sensitive. put FC-LX1D on to the input of ac/dc module can ensure the modul e meet surge level of iec/en61000-4-5 2kv (2 ? internal resistance)/4kv (12 ? internal resistance). put FC-LX1D2 on to the input of ac/dc module can ensure the module meet surge level of iec/en61000-4-5 4kv (2 ? internal resistance)/6kv (12 ? internal resistance) and emi requirement of cispr22 /en 55022 class b. emc filter used with the mornsun ac/dc module, ac/dc module?s ma x. input voltage must less than emc filter?s max. voltage, ac/d c module?s max. input current must le ss than emc filter?s nominal current. selection guide model input voltage range (vac) nominal current (a)(max) FC-LX1D 85~305 1.5 FC-LX1D2 85~305 1.5 note: series with suffix ?a2s? are chassis mounting, with suffix ?a4s? are din-rail mounting, for example FC-LX1Da4s. general specifications item test conditions min. typ. max. unit operating temperature -40 -- 85 storage temperature -55 -- 125 casing temperature rise 220vac @0.5a -- -- 5 220vac @1.0a -- -- 20 220vac @1.5a -- -- 30 test voltage (l/pe, n/pe) tested for 1 minute and leakage current: 1 ma -- 2000 -- vac general specifications casing material black flame-retardant heat-proof epoxy resin (ul94-v0) package dimensions FC-LX1D horizontal package 33.70x22.20x18.00 mm a2s wiring package 76.00x31.50x26.80 mm a4s rail package 76.00x31.50x31.40 mm FC-LX1D2 horizontal package 53.80x28.80x19.00 mm a2 swiring package 76.00x31.50x27.80 mm a4s rail package 76.00x31.50x32.40mm
emc filte r FC-LX1D & FC-LX1D2 series 201 4 .02.18- a /2 page 2of 7 mornsun guangzhou science & te chnology co., ltd. reserves the copyright and right of final interpretation weight FC-LX1D horizontal package/a2s wiring package/ a4s rail package 20g/40g/60g(typ) FC-LX1D2 50g/70g/90g(typ) fre q uenc y attenuation s p ecifications item test conditions min. typ. max. unit the attenuation coefficient of frequency 150khz?1ghz FC-LX1D -- 20 -- db FC-LX1D2 -- 30 -- devise standard put FC-LX1D on to the input of ac/dc module can ensure the module meet surge level of iec/en61000-4-5 2kv (2 ? internal resistance)/4kv (12 ? internal resistance). put FC-LX1D2 on to the input of ac/dc module can en sure the module meet surge level of iec/en61000-4-5 4kv (2 ? internal resistance)/6kv (12 ? internal resistance) and emi requirement of cispr22 /en 55022 class b. emc s p ecifications FC-LX1D surge test result input voltage waveform ( differential mode 2.11 kv) output voltage waveform ( differential mode 0.98kv) input voltage waveform ( common mode 4.06kv) output voltage waveform( common mode 0.88 kv) note: above result was tested on FC-LX1D open. FC-LX1D2 surge test result input voltage waveform ( differential mode 4.06kv) output voltage waveform ( differential mode 0.90kv)
emc filte r FC-LX1D & FC-LX1D2 series 201 4 .02.18- a /2 page 3of 7 mornsun guangzhou science & te chnology co., ltd. reserves the copyright and right of final interpretation input voltage waveform ( common mode 6.06kv) output voltage waveform( common mode 1.00kv) note: above result was tested on FC-LX1D2 open. desi g n reference 1. inside schematic in(n) in(l) out(n) out(l) (figure 1)FC-LX1D in(n) in(l) out(n) out ( l) (figure 2)FC-LX1D2 2. typical application ac(l) l n -vo fuse in(l) in(n) out(l) out(n) FC-LX1D2 output ac-dc converter +vo ac(n) fuse: due to the difference of the power mo dule input current, the fuse of the recomme nded values, please refer to the technica l manual for the power module. 3. supporting the product model model emi (without external circuit) emi (with emc filter) surge (without external circuit) surge (with FC-LX1D) surge (with FC-LX1D2) ld(01-03)-10bxx series cispr22/en55022 class a cispr22/en55022 class b -- iec/en61000-4-5 2kv/4kv perf. criteria b -- ld(05-10)-20bxx series cispr22/en55022class a cispr22/en55022 class b iec/en 61000-4-5 1kv perf. criteria b iec/en61000-4-5 2kv/4kv perf. criteria b iec/en61000-4-5 4kv/6kv perf. criteria b ld10-20bxxmu series cispr22/en55022class a cispr22/en55022 class b iec/en 61000-4-5 1kv perf. criteria b ec/en61000-4-5 2kv/4kv perf. criteria b iec/en61000-4-5 4kv/6kv perf. criteria b ld12-20bxx series cispr22/en55022 class b cispr22/en55022 class b iec/en 61000-4-5 2kv perf. criteria b -- iec/en61000-4-5 4kv/6kv perf. criteria b ld20-10bxx series cispr22/en55022 class b cispr22/en55022 class b iec/en 61000-4-5 2kv/4kv perf. criteria b -- iec/en61000-4-5 4kv/6kv perf. criteria b
emc filte r FC-LX1D & FC-LX1D2 series 201 4 .02.18- a /2 page 4 of 7 mornsun guangzhou science & te chnology co., ltd. reserves the copyright and right of final interpretation model emi (without external circuit) emi (with emc filter) surge (without external circuit) surge (with FC-LX1D) surge (with FC-LX1D2) lh(05-40)-10xxx series cispr22/en55022 class b cispr22/en55022 class b iec/en 61000-4-5 1kv/2kv perf. criteria b iec/en61000-4-5 2kv/4kv perf. criteria b iec/en61000-4-5 4kv/6kv perf. criteria b lbxx-10xxx series cispr22/en55022 class a cispr22/en55022 class b iec/en61000-4-5 1kv/2kv perf. criteria b iec/en61000-4-5 2kv/4kv perf. criteria b iec/en61000-4-5 4kv/6kv perf. criteria b li 24 series cispr22/en55022 class b cispr22/en55022 class b iec/en 61000-4-5 1kv/2kv perf. criteria b iec/en61000-4-5 2kv/4kv perf. criteria b ec/en61000-4-5 4kv/6kv perf. criteria b ls03 series -- cispr22/en55022 class b -- ec/en61000-4-5 2kv/4kv perf. criteria b -- dedicated power converter for power system lh(e) series cispr22/en55022 class b cispr22/en55022 class b iec/en 61000-4-5 2kv/4kv perf. criteria b -- ec/en61000-4-5 4kv/6kv perf. criteria b dedicated power converter for power system lh(er2) series cispr22/en55022 class a cispr22/en55022 class b iec/en 61000-4-5 2kv/4kv perf. criteria b -- ec/en61000-4-5 4kv/6kv perf. criteria b lm30-00j0512-03e cispr22/en55022 class b cispr22/en55022 class b iec/en 61000-4-5 2kv/4kv perf. criteria b -- ec/en61000-4-5 4kv/6kv perf. criteria b lo10-00b24e cispr22/en55022 class b cispr22/en55022 class b iec/en 61000-4-5 2kv/4kv perf. criteria b -- ec/en61000-4-5 4kv/6kv perf. criteria b 4. for more information please find the application notes on www.mornsun-power.com FC-LX1D dimensions and recommended layout
emc filte r FC-LX1D & FC-LX1D2 series 201 4 .02.18- a /2 page 5of 7 mornsun guangzhou science & te chnology co., ltd. reserves the copyright and right of final interpretation FC-LX1Da2s dimensions FC-LX1Da4s dimensions
emc filte r FC-LX1D & FC-LX1D2 series 201 4 .02.18- a /2 page 6of 7 mornsun guangzhou science & te chnology co., ltd. reserves the copyright and right of final interpretation FC-LX1D2 dimensions and recommended layout FC-LX1D2a2s dimensions
emc filte r FC-LX1D & FC-LX1D2 series 201 4 .02.18- a /2 page 7of 7 mornsun guangzhou science & te chnology co., ltd. reserves the copyright and right of final interpretation FC-LX1D2a4s dimensions note: 1. packing information please refer to 'produ ct packing information'. the packing bag number of horizontal package : 58220014 (FC-LX1D)/58220005(FC-LX1D2), the packing bag number of a2s/ a4s package:58220022; 2. unless otherwise specified, data in this data sheet should be tested under the conditions of ta=25 c, humidity<75%; 3. all index testing methods in this datasheet are ba sed on our company?s corporate standards; 4. the performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model produc ts will exceed the above-mentioned requirements, and please dire ctly contact our technicians for specific information; 5. we can provide product customization service; 6. specifications of this product are subj ect to changes without prior notice. mornsun guangzhou science & technology co., ltd. address: no. 5, kehui st. 1, kehui develo pment center, science ave., guangzhou scienc e city, luogang district, guangzhou, p. r. china tel: 86-20-38601850-8801 fax: 86-20-38601272 e-mail: info@mornsun.cn
|