www.white-rodgers.com 119a type 70 spno single pole normally open contact case is dust resistant and isolated from ground specifications dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . 2.47 ? l x 3.48 ? w x 2.40 ? h weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 oz. temperature range . . . . . . . . . . . . . . . . . . . -40 to +122f terminations, contacts . . . . . . . . . . . . . . . . . 5 / 16 ? -24 unf-2a thread terminations, coil . . . . . . . . . . . . . . . . . . . . . #10-32 unf-2a thread recommended mounting . . . . . . . . . . . . . . . . . . . plunger vertical with cap down hardware torque, contact terminal . . . . . . . . . . . 45-55 in. lbs. hardware torque, coil terminal . . . . . . . . . . . . . . 12-18 in. lbs. caution : a back-up wrench must be used to hold the bottom nut stationary. agency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . u.l. 538 recognized, file au2138 coil coil contact rating (amps) C inductive load model duty terminal pole bracket voltage resistance contact voltage normally open normally closed number cycle ? type ? form style d.c. (ohms) ? material d.c. continuous inrush continuous inrush 70-111225 continuous 3a spno standard 12 16 copper 12 80 400 60 60 70-111224 continuous 4 spno standard 12 16 copper 12 80 400 60 60 70-117224 continuous 4 spno standard 24 60 copper 24 50 50 30 30 70-120224 continuous 4 spno standard 36 114 copper 36 50 50 30 30 ? ?3a? = coil grounded to case ?4? = isolated coil ? coil resistance in ohms @ 25c ? intermittent duty designs available. type 120 spno single pole normally open contact, dust resistant, water resistant and case is isolated from bracket specifications dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 2.13 ? l x 2.88 ? w x 3.09 ? h (std. bracket) dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 2.50 ? l x 3.00 ? w x 3.03 ? h (l-shaped bracket) weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0 oz. temperature range, intermittent duty . . . . . -20 to +150f temperature range, continuous duty . . . . . -20 to +120f terminations, contacts . . . . . . . . . . . . . . . . . 5 / 16 ? -24 studs, .495 ? min. length terminations, coil . . . . . . . . . . . . . . . . . . . . . #10-32, .451 ? min. length recommended mounting . . . . . . . . . . . . . . . . . . . coil terminals up or horizontal hardware torque, contact terminal . . . . . . . . . . . 45-55 in. lbs. hardware torque, coil terminal . . . . . . . . . . . . . . 12-18 in. lbs. caution : a back-up wrench must be used to hold the bottom nut stationary. type 120 spno coil coil contact rating (amps) C inductive load model duty terminal pole bracket voltage resistance contact voltage normally open number cycle ? type ? form style d.c. (ohms) ? material d.c. continuous inrush ? 120-105711 continuous 4 spno standard 12 16.0 silver alloy 12 100 400 120-105851 continuous 3a spno standard 12 ? 16.0 silver alloy 12 100 400 120-106131 intermittent 4 spno standard 12 6.0 copper 12 80 400 120-106132 intermittent 4 spno l 12 6.0 copper 12 80 400 120-107112 continuous 4 spno l 14 26.0 silver alloy 14 100 400 ? intermittent duty cycle = 30 seconds ?on? maximum and 6 minutes ?off? ? ?4? = isolated coil ? coil resistance in ohms @ 25c ? inrush current: current applied within the rst 1/2 second of contact closure ? coil grounded to bracket note : caution must be used in coil selection for use in 12 volt sytems where battery charging may expose coil to continuous, higher-than-rated voltage. 14 volt coils are recommended. white-rodgers will not be responsible for consequences of misap- plied solenoids. spno dc power contactors warning ? fire hazard must be installed in a dry and protected place. failure to protect solenoid from water and other contaminants could result in fire, property damage, serious personal injury, or death. type 70 spno
|