106 filter selection table choose the filter fn xxxx-x with the required current rating and features, and add /?? to determine input/output (line/load) connection style. example: fn 2020-10/06 is a 10a filter with fast-on connections. 1 (1.15) 3 (3.45) 6 (6.9) 10 (11.5) 12 (13.8) 16 (18.4) 20 (23) 30 (34.5) 60 (69) current ratings at 40c (25) a fn 2020 -1 /?? fn 2020 -3 /?? fn 2020 -6 /?? fn 2020 -10 /?? fn 2020 -12 /?? fn 2020 -16 /?? fn 2020 -20 /?? fn 2020 -30 /?? fn 2020 -60 /?? filter /06 /06 /06 /06 /06 /06 /06 /07 /07 /07 /07 /07 /07 /08 /08 /24 connections f2 f2 f2 f2 f2 h2 k1 p l2 housing 80 80 80 85 85 140 210 470 1100 weight g 1 000 000 1 750 000 1 000 000 mtbf per mil-hb-217f at 40oc 230v hours 2000 1700 2500 1700 2500 1700 filter type 0.4* 0.002 0.040 maximum leakage ma/phase 250 50/60 250 50/60 250 50/60 maximum operating voltage vac hz hipot test voltage pn e p n vac vdc operating frequency hz dc to 400 dc to 400 dc to 400 * 1ma for 30a and 60a versions additional specifications approvals 12 0.15 4.7 1 2.5 0.15 4.7 1 1 0.15 4.7 1 0.8 0.15 4.7 1 0.7 0.15 4.7 1 0.65 0.15 4.7 1 0.6 0.15 4.7 1 0.67 0.47 10 0.47 1 1.5 10 0.22 inductance capacitance resistance lcxcyr mh fnf m standard types b medical types (no y capacitors) a safety types (lower capacitance) fn 2020 ? current ratings from 1 to 60a ? high differential mode attenuation ? optional medical versions (b types) ? optional safety versions (a types) ? nennstr?me von 1 bis 60a ? hohe d?mpfung im symmetrischen betrieb ? optionale medizinische versionen (typ b) ? optionale sicherheitsversionen (typ a) ? courants de service de 1 60 a ? bonne attnuation en mode diffrentiel ? en option version pour appareils mdicaux (type b) ? en option version pour la scurit (type a) general-purpose filter electrical schematic e cx r l fn 2020 line load cy cy n p n' p' see tables for component values. cx
107 0.5 0.5 0.5 0.5 0.3 0.2 0.5 0.5 0.1 0.1 0.1 0.5 tol.* mm * measurements share this common tolerance unless otherwise stated. fn 2020 insertion loss per cispr 17; a = 50 /50 sym, b = 50 /50 asym, c = 0.1 /100 sym, d = 100 /0.1 sym * attenuation performance of the 12a version is similar to the 10a component. 1a types db 70 60 50 40 30 20 10 0 -10 -20 10k 100k 1m 10m 3a types db 70 60 50 40 30 20 10 0 -10 -20 10k 100k 1m 10m 6a types db 70 60 50 40 30 20 10 0 -10 -20 10k 100k 1m 10m 16a types db 70 60 50 40 30 20 10 0 -10 -20 10k 100k 1m 10m 20a types db 70 60 50 40 30 20 10 0 -10 -20 10k 100k 1m 10m 30a types db 70 60 50 40 30 20 10 0 -10 -20 10k 100k 1m 10m 60a types db 70 60 50 40 30 20 10 0 -10 -20 10k 100k 1m 10m 10a types (12a*) db 70 60 50 40 30 20 10 0 -10 -20 10k 100k 1m 10m 64 0.3 71 85 35 46.6 54 29.3 30.3 43.5 50.5 64.8 54 61 75 21 27 8.3 /9.3 10.8/8.3 12.3/8.3 15.3 19.3 20.8/23.3 5.3 6.3 0.7 20.1/30.5 19.9/34.9 /21.4 ? f2 h2 k1 a b c d f j k l m n p s housing style mechanical data with /07 connections ? with /08 connections wire length of /07: 140 +5 mm 1 1 1 1 0.3 0.2 0.5 0.5 0.1 0.1 0.1 0.2 0.5 tol.* mm * measurements share this common tolerance unless otherwise stated. a b c d f j k l m n p r s housing style 113.5 105 0.5 57.5 99.5 45.4 1.2 57.6 94 84.5 103 95 25 40 12.4 10.1 32.4 20 4.4 6 0.9 79 51 15.5 pl2 front to p housing f2 housings h2, k1 c k j m n l f b d f a d p l p k c j s m n b a housing p m l d f a p k c j s n b to p front all dimensions in mm; 1 inch = 25.4 mm k l c j m n p a r f d b housing l2
|