509fx-a industrial ethernet switch n-tron networking series unmanaged industrial ethernet switch advanced management features the 509fx-a offers several management functions that can be easily con ? gured using the com port (db 9 connector located on the right side of the switch). igmp snooping: internet group management protocol allows the n-tron switch to intelligently forward and ? lter multicast traf ? c. vlan: virtual local area network allows switch segmentation in order to create two or more separate local area network domains. qos: quality of service streamlines network operation by managing packet priority. the primary goal of qos is to improve the latency of prioritized ethernet packets required for ring management, real-time and other interactive applications. trunking : trunking (aggregation) enables multiple physical ports to be linked together and function as one uplink to another identically con ? gured trunking- capable switch. this feature increases the bandwidth between switches and creates redundancy for applications requiring high levels of fault tolerant operation. port mirroring: port mirroring allows traf ? c on one port to be duplicated and sent to a designated mirror port. this function can be used to monitor ethernet traf? c on the designated source port using the assigned mirror port. n-view opc switch monitoring: (with -a or -n option only) n-view opc server software can be used with popular hmi software packages to transmit operational information from n-view-capable switches. this technology enables network traf ? c monitoring, as well as alarm and trending details. in all, the n-view opc server collects 41 different traf ? c variables per port and ? ve system level variables per switch, providing a complete overview of network load, service quality, and packet traf ? c. empowered with n-view opc server data, users can resolve network problems faster and make more informed decisions about overall system performance. the industrial network company www.n-tron.com rugged ? reliable ? affordable 509fx-a product features ? full ieee 802.3 and 1613 compliance ? nema ts1/ts2 compliance ? american bureau of shipping (abs) type approval ? eight (8) 10/100 basetx rj-45 ports ? one (1) 100basefx port, st (shown) or sc ? -40oc to 85oc operating temperature ? auto sensing 10/100basetx, duplex, and mdix ? store-and-forward technology ? up to 1.8 gb/s maximumthroughput ? rugged industrial din-rail enclosure ? redundant power inputs (10-30 vdc) ? bi-color leds for link, speed, activity & duplex status advanced management functions (with -a option only): ? igmp snooping ? vlan ? qos ? trunking and mirroring ? n-view ? (remote monitoring using opc technology) product overview the n-tron ? 509fx series industrial ethernet switch offers outstanding performance and ease of use. it is ideally suited for connecting ethernet enabled industrial and/or security equipment and can be optionally con ? gured with advanced ethernet communication management functions. industrial packaging and speci ? cations the 509fx, designed to operate in industrial environments, is housed in a rugged din-rail-mounted steel enclosure. optional panel and rack mount kits are also available. the switch comes standard with extended temperature rating, extended shock and vibration specs, redundant power inputs, and a high mtbf (greater than 2m hours). ease of use the 509fx requires no setup unless the advanced port functions are utilized. the eight 10/100basetx ports are auto sensing and auto con ? guring. each copper port automatically negotiates for maximum speed and performance by default. the ? ber optic port supports full 200mb/s communications via 100basefx. bi-color leds are provided to display the link status, link speed and activity of each port as well as power on/off status. performance the 509fx supports up to 4,000 mac addresses and uses advanced ieee 802.3 fast ethernet 10/100basetx switching technology to eliminate network collisions and increase network determinism. a high-speed processor and backplane allow full-wire speed capability on all ports simultaneously.
509fx-a specifications www.n-tron.com 509fx-a speci? cations switch properties number of mac addresses: 4,000 aging time: 300s, programmable (-a option) latency typical: 2.1 s switching method: store & forward case dimensions height: 2.3" (5.8 cm) width: 5.5" (13.9 cm) depth: 3.5" (8.9 cm) weight: 1.6 lbs (0.8 kg) din-rail: 35 mm electrical redundant input voltage: 10-30 vdc input current: 260 ma @ 24 vdc btu/hr: 21.3 @ 24 vdc inrush: 8.5 amp/0.7ms @24 vdc environmental operating temperature: -40 o c to 85 o c storage temperature: -40 o c to 85 o c operating humidity: 10% to 95% (non condensing) operating altitude: 0 to 10,000 ft. shock and vibration (bulkhead mounted) shock: 200 g @ 10ms vibration/seismic: 50 g, 5-200 hz, triaxial reliability mtbf: >2 million hours serial con? guration port com parameters: 9600,n,8,1 network media 10baset: cat3 cable 100basetx: cat5 cable 100basefx: multimode: 50-62.5/125 m singlemode: 7-10/125 m connectors 10/100basetx: eight (8) rj-45 copper ports 100basefx: one (1) sc or st duplex port recommended wiring clearance front: 4" (10.2 cm) side: 1" (2.6 cm) regulatory approvals fcc/ce (cfr 47, part 15, subpart b, class a); ices-003 emc dir 89/336/eec, en 50204, en 55011 en61000-4-2, 3, 4, 5, 6, 8,11, en61000-6-2, 4 ansi c63.4 ul /cul: class i, div 2, groups a, b, c, d and t4 ul 508 and ul 1604 can/csa-c22.2 no.213, atex ii 3 g ex na ieee 1613 for electric utility substations abs type approval for shipboard applications gost-r certi ? ed, rohs compliant designed to comply with: nema ts1/ts2 for traf ? c control fiber transceiver characteristics fiber length 2km* 15km** 40km** 80km** tx power min -19dbm -15dbm -5dbm -5dbm rx sensitivity max -31dbm -31dbm -34dbm -34dbm wavelength 1310nm 1310nm 1310nm 1550nm * multimode fiber optic cable ** singlemode fiber optic cable www.n-tron.com 509fx-a speci? cations switch properties number of mac addresses: 4,000 aging time: 300s, programmable (-a option) latency typical: 2.1 s switching method: store & forward case dimensions height: 2.3" (5.8 cm) width: 5.5" (13.9 cm) depth: 3.5" (8.9 cm) weight: 1.6 lbs (0.8 kg) din-rail: 35 mm electrical redundant input voltage: 10-30 vdc input current: 260 ma @ 24 vdc btu/hr: 21.3 @ 24 vdc inrush: 8.5 amp/0.7ms @24 vdc environmental operating temperature: -40 o c to 85 o c storage temperature: -40 o c to 85 o c operating humidity: 10% to 95% (non condensing) operating altitude: 0 to 10,000 ft. shock and vibration (bulkhead mounted) shock: 200 g @ 10ms vibration/seismic: 50 g, 5-200 hz, triaxial reliability mtbf: >2 million hours serial con? guration port com parameters: 9600,n,8,1 network media 10baset: cat3 cable 100basetx: cat5 cable 100basefx: multimode: 50-62.5/125 m singlemode: 7-10/125 m connectors 10/100basetx: eight (8) rj-45 copper ports 100basefx: one (1) sc or st duplex port recommended wiring clearance front: 4" (10.2 cm) side: 1" (2.6 cm) regulatory approvals fcc/ce (cfr 47, part 15, subpart b, class a); ices-003 emc dir 89/336/eec, en 50204, en 55011 en61000-4-2, 3, 4, 5, 6, 8,11, en61000-6-2, 4 ansi c63.4 ul /cul: class i, div 2, groups a, b, c, d and t4 ul 508 and ul 1604 can/csa-c22.2 no.213, atex ii 3 g ex na ieee 1613 for electric utility substations abs type approval for shipboard applications gost-r certi ? ed, rohs compliant designed to comply with: nema ts1/ts2 for traf ? c control fiber transceiver characteristics fiber length 2km* 15km** 40km** 80km** tx power min -19dbm -15dbm -5dbm -5dbm rx sensitivity max -31dbm -31dbm -34dbm -34dbm wavelength 1310nm 1310nm 1310nm 1550nm * multimode fiber optic cable ** singlemode fiber optic cable www.n-tron.com 509fx-a speci? cations switch properties number of mac addresses: 4,000 aging time: 300s, programmable (-a option) latency typical: 2.1 s switching method: store & forward case dimensions height: 2.3" (5.8 cm) width: 5.5" (13.9 cm) depth: 3.5" (8.9 cm) weight: 1.6 lbs (0.8 kg) din-rail: 35 mm electrical redundant input voltage: 10-30 vdc input current: 260 ma @ 24 vdc btu/hr: 21.3 @ 24 vdc inrush: 8.5 amp/0.7ms @24 vdc environmental operating temperature: -40 o c to 85 o c storage temperature: -40 o c to 85 o c operating humidity: 10% to 95% (non condensing) operating altitude: 0 to 10,000 ft. shock and vibration (bulkhead mounted) shock: 200 g @ 10ms vibration/seismic: 50 g, 5-200 hz, triaxial reliability mtbf: >2 million hours serial con? guration port com parameters: 9600,n,8,1 network media 10baset: cat3 cable 100basetx: cat5 cable 100basefx: multimode: 50-62.5/125 m singlemode: 7-10/125 m connectors 10/100basetx: eight (8) rj-45 copper ports 100basefx: one (1) sc or st duplex port recommended wiring clearance front: 4" (10.2 cm) side: 1" (2.6 cm) regulatory approvals fcc/ce (cfr 47, part 15, subpart b, class a); ices-003 emc dir 89/336/eec, en 50204, en 55011 en61000-4-2, 3, 4, 5, 6, 8,11, en61000-6-2, 4 ansi c63.4 ul /cul: class i, div 2, groups a, b, c, d and t4 ul 508 and ul 1604 can/csa-c22.2 no.213, atex ii 3 g ex na ieee 1613 for electric utility substations abs type approval for shipboard applications gost-r certi ? ed, rohs compliant designed to comply with: nema ts1/ts2 for traf ? c control fiber transceiver characteristics fiber length 2km* 15km** 40km** 80km** tx power min -19dbm -15dbm -5dbm -5dbm rx sensitivity max -31dbm -31dbm -34dbm -34dbm wavelength 1310nm 1310nm 1310nm 1550nm * multimode fiber optic cable ** singlemode fiber optic cable www.n-tron.com 509fx-a speci? cations switch properties number of mac addresses: 4,000 aging time: 300s, programmable (-a option) latency typical: 2.1 s switching method: store & forward case dimensions height: 2.3" (5.8 cm) width: 5.5" (13.9 cm) depth: 3.5" (8.9 cm) weight: 1.6 lbs (0.8 kg) din-rail: 35 mm electrical redundant input voltage: 10-30 vdc input current: 260 ma @ 24 vdc btu/hr: 21.3 @ 24 vdc inrush: 8.5 amp/0.7ms @24 vdc environmental operating temperature: -40 o c to 85 o c storage temperature: -40 o c to 85 o c operating humidity: 10% to 95% (non condensing) operating altitude: 0 to 10,000 ft. shock and vibration (bulkhead mounted) shock: 200 g @ 10ms vibration/seismic: 50 g, 5-200 hz, triaxial reliability mtbf: >2 million hours serial con? guration port com parameters: 9600,n,8,1 network media 10baset: cat3 cable 100basetx: cat5 cable 100basefx: multimode: 50-62.5/125 m singlemode: 7-10/125 m connectors 10/100basetx: eight (8) rj-45 copper ports 100basefx: one (1) sc or st duplex port recommended wiring clearance front: 4" (10.2 cm) side: 1" (2.6 cm) regulatory approvals fcc/ce (cfr 47, part 15, subpart b, class a); ices-003 emc dir 89/336/eec, en 50204, en 55011 en61000-4-2, 3, 4, 5, 6, 8,11, en61000-6-2, 4 ansi c63.4 ul /cul: class i, div 2, groups a, b, c, d and t4 ul 508 and ul 1604 can/csa-c22.2 no.213, atex ii 3 g ex na ieee 1613 for electric utility substations abs type approval for shipboard applications gost-r certi ? ed, rohs compliant designed to comply with: nema ts1/ts2 for traf ? c control fiber transceiver characteristics fiber length 2km* 15km** 40km** 80km** tx power min -19dbm -15dbm -5dbm -5dbm rx sensitivity max -31dbm -31dbm -34dbm -34dbm wavelength 1310nm 1310nm 1310nm 1550nm * multimode fiber optic cable ** singlemode fiber optic cable www.n-tron.com 509fx-a www.n-tron.com 509fx-a www.n-tron.com 509fx-a
509fx-a specifications as the global experts in communication, monitoring and control for industrial automation and networking, red lion has been delivering innovative solutions for over forty years. our award-winning technology enables companies worldwide to gain real-time data visibility that drives productivity. product brands include red lion, n-tron and sixnet. with headquarters in york, pennsylvania, the company has offces across the americas, asia-pacifc and europe. for more information, please visit www.redlion.net. red lion is a spectris company. www.redlion.net connect. monitor. control. adld0299 070313 ?2013 red lion controls americas sales@redlion.net asia-pacifc asia@redlion.net europe middle east africa europe@redlion.net +1 (717) 767-6511 ordering information part number description 509FX-A-XX .............................................. 9-port (8 10/100basetx, 1 100basefx fiber uplink, multimode) industria l ethernet switch, din-rail with advanced management features (includes n-view) 509fxe-a-xx-yy ...................................... 9-port (8 10/100basetx, 1 100basefx fiber uplink, singlemode) industrial e thernet switch, din-rail with advanced management features (includes n-view) 509fx-n-xx .............................................. 9-port (8 10/100basetx, 1 100basefx fiber uplink, multimode) industria l ethernet switch, din-rail with n-view opc switch monitoring 509fxe-n-xx-yy ...................................... 9-port (8 10/100basetx, 1 100basefx fiber uplink, singlemode) industrial e thernet switch, din-rail l with n-view opc switch monitoring 509fx-xx .................................................. 9-port (8 10/100basetx, 1 100basefx fiber uplink, multimode) industr ial ethernet switch, din-rail 509fxe-xx-yy .......................................... 9-port (8 10/100basetx, 1 100basefx fiber uplink, singlemode) industrial ethernet switch, din-rail ntps-24-1.3 .............................................. n-tron power supply (1.3 amp @ 24 vdc) 900-pm ...................................................... panel mount kit - converts switch from din-rail to panel mount. urmk ........................................................ universal rack mount kit 500-uta89 ................................................ metal din-rail clip where: a = advanced management features (includes n-view) n = n-view opc switch monitoring e = singlemode xx = st for st style ? ber connector, sc for sc style ? ber connector yy = segment length: 15 for 15km max. ? ber segment length 40 for 40km max. ? ber segment length 80 for 80km max. ? ber segment length 509fx ? 2011 n-tron corporation. n-tron and the n-tron logo are trademarks of n-tron, corporation. product names mentioned herein are for identi? cation purposes only and may be trademarks and/or registered trademarks of their respective company. the responsibility for the use and application of n-tro n products rests with the end user. n-tron makes no warranties as to the ? tness or suitability of any n-tron product for any speci ? c application. n-tron corporation shall not be liable for any damage resulting from the installation, use, or misuse of this product. speci ? cations subject to change without notice. rev 2011.05.26 please visit us worldwide at www.n-tron.com n-tron usa & corporate headquarters 820 s. university blvd ? suite 4e mobile, al 36609 ? usa phone +1-251-342-2164 fax +1-251-342-6353 www.n-tron.com n-tron asia pacific china phone +86 (0) 21-6113-3688 fax +86 (0) 21-6113-3683 india phone +91-9844-876540 singapore phone +65-8118-6821 n-tron emea phone +41-41-740-6636 fax +41-41-740-6637 n-tron uk/ireland/nordic/benelux phone +44 (0) 1928-577257
|