  ver : b_9 update : 2016.09.01 ac-dc power module aqc100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. aqc100-12s aqc100- 15s aqc100-24s AQC100-48S max output wattage (w) 85 w 85w 100w 100w voltage 90-264 vac or 120-370 vdc frequency (hz) 47-63 hz current (full load) <2.0 a max. (115 vac) / <1.0 a max. (230 vac) inrush current (<2ms) < 30 a max. (115 vac) / < 60 a max. (230 vac) leakage current < 0.5 ma max. input power factor pf>0.99 (115 vac) / pf>0.95 (230 vac) at full load voltage (v.dc.) 12v 15v 24v 48v voltage accuracy 2% current (a) max 7.08 5.66 4.2 2.1 line regulation (ll-hl) (typ.) 1% load regulation (5-100%) (typ.) 1% minimum load 3% maximum capacitive load (at 230vac) 50,000f 40,000f 6,000f 560f ripple & noise max. 120mv 150mv 200mv 240mv efficiency (typ.) 90% 90% 92% 93% output hold-up time 10 ms (110 vac) min. over power protection auto recovery, 105 ~ 180% rated output power over voltage protection zener diode clamp protection short circuit protection auto recovery, hiccup mode input-output (v.ac) 3000v input-fg (v.ac) 1500v isolation output-fg . (v.ac) 500v operating temperature -25c?+70c (with derating) storage temperature -25c?+85c temperature coefficient 0.03%/c ( 0~50c ) humidity 95% rh mtbf >250,000 h @ 25c (mil-hdbk-217f, notice 1) environment vibration 10~500hz, 2g 10min./1cycle, 60min. each along x, y, z axes. dimension (l x w x h) 4.3 x 2.3 x 1.18 inches ( 109.0 x 58.5 x 30.0 mm ) tolerance ? 0.1 mm case material plastic resin (flammability to ul 94v-0) weight 362 g physical cooling method free convection safety agency approvals ce, ul60950-1, cb emi (conducted & radiated emission) en61000-6-3 en 55022 class b (conductive plane to be connected to safety earth) ems (noise immunity) en 55024 en61000-4-2,3,4,5,6,8,11 emc surge 2kv l-n, 4kv l n-fg key features ? switching power module for pcb mountable ? high efficiency up to 93% typical ? active pfc function, >0.95 (230vac), >0.99 (115vac) ? universal input: 90-264 vac ? low leakage current, <250ua ? four m3 mounting holes optional on bottom side ? remote on/off control ? en55022 class b meets ? class i and class ii construction ? continuous short circuit protection with hiccup mode and auto recover ? 3-year product warranty
ver : b_9 update : 2016.09.01 ac-dc power module aqc100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- note 1. ripple & noise are measured at 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor. 2. hold-up time measured at 90% vout. 3. it's necessary varistor 14s471k at l / n input side in parallel. 4. it's necessary 10r / 15 thermistor at l input side in series connection. 5. the minimum load increases by 0.16% for every drop of one degree of temperature(at input=90~219vac) 6. please refer to our pdf file "ac-dc applic ation" on our website: www.archcorp.com.tw mechanical dimension ( top view ) pin# single 1 1.2 0.1%mm ac in (n) 2 1.2 0.1%mm ac in (l) 3 1.2 0.1%mm fg 4 1.2 0.1%mm on / off (provide +5vdc controlled) 5 1.8 0.1%mm +dc out 6 1.8 0.1%mm -dc out 7 1.2 0.1%mm trim remark: please reserve the pin 4 hole on pcb. if the remote on/off function is not required, please connect the pin 4 circuit lay out with pin6, or keep pin 4 floating. derating
ver : b_9 update : 2016.09.01 ac-dc power module aqc100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- block diagram efficiency versus load aqc100-12s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 87.87 89.51 90.67 90.88 90.96 load (%) 10 20 30 40 50 115v (%) 78.62 85.67 88.07 89.14 89.76 230v (%) 73.49 83.84 86.57 88.55 89.76 load (%) 60 70 80 90 100 115v (%) 89.95 90.00 90.02 89.77 89.51 230v (%) 90.22 90.58 90.83 90.85 90.88 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% 12s 15s 24s 48s +5% 0% +5% 0% +5% 0% +5% 0% trim -v 85k ~ 1.5m 95k ~1.7m 90k ~4m 85k ~ 15m 0% -5% 0% -5% 0% -5% 0% -5% trim +v 1.5m ~ 220k 1.7m ~ 300k 4m ~ 600k 15m ~ 1.5m
ver : b_9 update : 2016.09.01 ac-dc power module aqc100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -4- efficiency versus load aqc100-15s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 88.41 90.17 91.11 91.59 91.53 load (%) 10 20 30 40 50 115v (%) 74.53 83.09 86.59 88.41 89.20 230v (%) 73.94 82.70 85.31 87.77 89.14 load (%) 60 70 80 90 100 115v (%) 89.70 89.93 89.99 90.11 90.17 230v (%) 89.97 90.63 90.91 91.15 91.59 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% aqc100-24s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 90.45 92.45 93.62 93.35 93.26 load (%) 10 20 30 40 50 115v (%) 80.71 87.31 90.00 91.22 92.10 230v (%) 73.64 84.39 88.42 90.56 91.76 load (%) 60 70 80 90 100 115v (%) 92.41 92.51 92.53 92.47 92.45 230v (%) 92.54 92.97 93.28 93.52 93.35 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
ver : b_9 update : 2016.09.01 ac-dc power module aqc100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -5- efficiency versus load AQC100-48S vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 91.22 93.13 94.24 94.59 94.66 load (%) 10 20 30 40 50 115v (%) 82.39 88.10 90.73 91.67 92.58 230v (%) 71.87 83.73 89.12 91.05 92.41 load (%) 60 70 80 90 100 115v (%) 92.92 93.02 93.11 93.16% 93.13 230v (%) 93.18 93.63 93.95 94.32 94.59 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%


▲Up To Search▲   

 
Price & Availability of AQC100-48S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X