www.pairuigroup.com page: 1 / 4 date: 11/09/2015 *subject to change without notice ac-dc converter dip-package ASD-10 series, 10watt features: wide input voltage range short circuit, over current protections board in-line type installation high voltage isolation 4000vac 100% burn-in test 3 year warranty model input voltage (vac) output voltage (vdc) output current (ma) efficiency typ. asd10-3 85-264 3.3 2000 66% asd10-5 5 2000 76% asd10-9 9 1111 80% asd10-12 12 830 81% asd10-15 15 666 82% asd10-24 24 420 83% note: other input and output models may available on request . electrical input parameters symbols test conditions / comment min. typ. max. units input voltage v in --- 85 -- 264 vac input frequency f line --- 47 -- 440 hz input current i in full load, v in =115vac -- 210 -- ma full load, v in =230vac -- 110 -- ma inrush current i inrush cold start, v in =1150vac -- 16 -- a cold start, v in =230vac -- 30 -- a leakage current i leakage v in =230vac/50hz -- -- 0.1 ma external fuse -- t1a/250vac(disconnected slowly)
www.pairuigroup.com page: 2 / 4 date: 11/09/2015 *subject to change without notice ac-dc converter dip-package ASD-10 series, 10watt electrical output parameters symbols test conditions / comment min. typ. max. units output voltage accuracy v out v in =220-305vac -- 2 -- % line regulation v out-line v in from 220vac to 305vac -- 1 -- % load regulation v out-load 20%-100% load -- 1 -- % set-up rise time -- full load, v in =230vac -- 110 -- ms hold-up time -- full load, v in =230vac -- 40 -- ms ripple v ripple v o =3.3v, 5v -- 50 -- mv v o =9v, 12v, 15v, 24v -- 100 -- mv protection over current it will auto-recovery after fault condition is removed over voltage it will auto-recovery after fault condition is removed short circuit hiccup mode, it will auto-recovery after faul t condition is removed environment storage t storage humidity: 10% rh to 95% rh -40 -- +85 ambient operating temperature t a startup at rated voltage (please refer to derating curve) -40 -- +70 operating relative humidity h a non condensing 10 -- 95 % mtbf t mtbf full load, 230vac input, 25 ambient temperature 200 -- -- khrs dimension(lxwxh) 50.8 x 25.4 x 15.3mm safety safety standards design refer to ul1012, en60950, ul60950 withstand voltage i/p-o/p:4kvac insulation resistance i/p-o/p: 100m ohms/500vdc/25 /70%rh emi / rfi conducted en55011, en55022 (cispr22) class b
www.pairuigroup.com page: 3 / 4 date: 11/09/2015 *subject to change without notice ac-dc converter dip-package ASD-10 series, 10watt electrical notes: 1. unless otherwise specified, all the above paramet ers are measured at ambient temperature of 25 and input nominal voltage; 2. ripple & noise are measured at 20mhz of bandwidth by using a 300mm twisted pair-wire terminated with a 0.1f & 47f parallel capacitor. mechanical connection pin # single 1 ac(n) 2 ac(l) 3 +vo 4 -vo note: unit is mm(inch). electrical curve derating curve static characteristic curve
www.pairuigroup.com page: 4 / 4 date: 11/09/2015 *subject to change without notice ac-dc converter dip-package ASD-10 series, 10watt note block diagram recommended test and application circuit components 3.3v 5v 9v 12v 15v 24v fuse t1a/250v ntc 10d-9 nf common mode choke, inductance=10mh, current=0.2-0.5a mov 14d471k c1 x capacitor, 104k/400v c2/c3 y capacitor, 102k/400v c4 470uf/16v 470uf/16v 150uf/16v 120uf/16v 120uf/25v 100u f/35v c5 104k/50v d1 p6ke6.8a p6ke6.8a p6ke16a p6ke16a p6ke206a p6ke33a
|