Part Number Hot Search : 
C0805C1 51021 AN804 2SK192 67040 68HC7 284136 G5996A
Product Description
Full Text Search
 

To Download VHD1-DIP Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  for more information, please visit the product page. ????????? ?????????????????? cui .com date 01/13/2014 page 1 of 5 series : VHD1-DIP description: dc-dc converter date 01/13/2014 page 1 of 5 features ? 1 w isolated output ? industry standard 17 pin dip package ? single unregulated outputs ? 6,000 v isolation ? short circuit protection ? ul safety approvals ? wide temperature (-40~85c) ? efficiency up to 75% rohs part number key model input voltage output voltage output current output power ripple and noise 1 effciency typ (vdc) range (vdc) (vdc) min (ma) max (ma) max (w) max (mvp-p) typ (%) vhd1-s5-s5-dip 5 4.5~5.5 5 20 200 1 150 68 vhd1-s5-s9-dip 5 4.5~5.5 9 12 111 1 150 72 vhd1-s5-s12-dip 5 4.5~5.5 12 9 84 1 150 74 vhd1-s5-s15-dip 5 4.5~5.5 15 7 67 1 150 74 vhd1-s12-s5-dip 12 10.8~13.2 5 20 200 1 150 69 vhd1-s12-s9-dip 12 10.8~13.2 9 12 111 1 150 72 vhd1-s12-s12-dip 12 10.8~13.2 12 9 84 1 150 74 vhd1-s12-s15-dip 12 10.8~13.2 15 7 67 1 150 75 notes: 1. ripple and noise are measured at 20 mhz bw vhd1 - s xx - s xx -dip input voltage output voltage base number packaging style
for more information, please visit the product page. ?????????????????? cui .com cui inc series : VHD1-DIP description: dc-dc converter date 01/13/2014 page 2 of 5 input parameter conditions/description min typ max units operating input voltage 5 v model 12 v model 4.5 10.8 5 12 5.5 13.2 vdc vdc output parameter conditions/description min typ max units line regulation for vin change of 1% 1.2 % load regulation measured from 10% load to full load 10 15 % voltage accuracy see derating curves switching frequency 100% load, input voltage range 250 khz temperature coeffcient 0.03 %/c protections parameter conditions/description min typ max units short circuit protection 1 s safety and compliance parameter conditions/description min typ max units isolation voltage for 1 minute at 1 ma max. 6,000 vdc isolation resistance at 500 vdc 1,000 m? safety approvals ul 60950 (e222736) mtbf 3,500,000 hours rohs compliant yes environmental parameter conditions/description min typ max units operating temperature -40 85 c storage temperature -55 125 c storage humidity non-condensing 95 % temperature rise at full load 15 25 c lead temperature 1.5 mm from case for 10 seconds 300 c
for more information, please visit the product page. ?????????????????? cui .com cui inc series : VHD1-DIP description: dc-dc converter date 01/13/2014 page 3 of 5 mechanical parameter conditions/description min typ max units dimensions 32.30 x 14.70 x 9.40 (0.768 x 0.396 x 0.492 inch) mm case material plastic (ul94-v0) weight 4.2 g t op v iew side v iew layout 0.65 27.94 4.00 9.40 32.30 14.70 1 13 29 12 10 11 24 23 17 16 15 14 8 24 23 17 16 15 14 13 2.54 2.54 12 89 10 11 12 1.00 + 0.15 / - 0 mechanical drawing pin connections pin function 1 +vin 2 -vin 8 nc 10 -vout 12 +vout 13 +vout 15 -vout 17 nc units: mm tolerance: 0.25 pin section tolerance: 0.10 mm am bi en t te mp erat ur e ( ? ) derating curves 1. output power vs. ambient temperature 2. output voltage vs. output current 100 80 60 40 20 ambient t emper ature (c) load (% ) -40- 20 02 04 06 07 1 85 100 120
for more information, please visit the product page. ?????????????????? cui .com cui inc series : VHD1-DIP description: dc-dc converter date 01/13/2014 page 4 of 5 application notes dc c l l dc c +v in -v in +v out -v out figure 1 input voltage external input capacitance 5 v 4.7 f 12 v 2.2 f 24 v 1.0 f table 1 table 2 figure 2 output voltage external input capacitance 5 v 4.7 f 9 v 2.2 f 12 v 1.0 f 15 v 0.47 f re g dc dc dc dc re g +v in -v in +v out -v out +v in -v in +v out -v out 1. input fltering to reduce the refected ripple current and minimize emi, especially when the converter input is more than 2 away from the dc source, it is recommended to connect a low esr electrolytic capacitor between vin and gnd. the values suggested are as shown in table 1. if additional fltering is required, the capacitance may be increased, or expanded to an lc network as shown in figure 1. 2. output fltering an output capacitor is needed to meet output ripple requirements as shown in table 2. output capacitance may be increased for ad - ditional fltering, but should not exeed 10f or expanded to an lc network as in figure 1. 3. minimum loading the converter needs a minimum of 10% loading to maintain output regulation. operation under no-load conditions will not cause im - mediate damages but may reduce reliability, and cause performance not to meet specifcations. 4. regulation with a semi-regulated design, the converters output voltage varies with load current and will change proportionally to the input volt - age. if regulated output is needed, an external regulator can be used as shown in figure 2. 5. protection the converter has minimal protection against input over-voltage or output over-load, and may be permanently damaged if exposed to these conditions. an input clamping device can be used for input voltage limiting. an input fuse or an output fuse can also be used to protect against over-loading. 6. dual outputs used as a single output the +vout and -vout can be used to obtain a single output that is the sum of the two outputs. in this case, the com pin shouldnt be used. 7. external regulator an external 3-terminal regulator can be connected to the output of the converter to achieve full regulation. make sure the converters output voltage provides suffcient head room for the regulator. an additional beneft is that the built-in protection features in the regu - lator, such as ocp, otp, etc, will protect the converter also. in a complimentory supply, a negative output regulator must be used to achieve the negative regulated output. note: all specifcations measured at 25c, humidity <75%, nominal input voltage, and full load unless otherwise noted.
for more information, please visit the product page. ????????? cui inc series : VHD1-DIP description: dc-dc converter date 01/13/2014 page 5 of 5 cui offers a two (2) year limited warranty. complete warranty information is listed on our website. cui reserves the right to make changes to the product at any time without notice. information provided by cui is believed to be accurate and reliable. however, no responsibility is assumed by cui for its use, nor for any infringements of patents or other rights of third parties which may result from its use. cui products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. a critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. headquarters 20050 sw 112th ave. tualatin, or 97062 800.275.4899 fax 503.612.2383 cui .com techsupport@cui.com rev. description date 1.0 initial release 05/12/2006 1.01 new template applied, v-infnity branding removed 09/07/2012 1.02 updated spec 01/13/2014 the revision history provided is for informational purposes only and is believed to be accurate. revision history


▲Up To Search▲   

 
Price & Availability of VHD1-DIP

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X