  diesel generator set mtu 12v4000 ds1550 s tand by p o wer : 1550 kw el 380v/60 hz/water charge air cooling/fuel consumption optimized p roduct h ighlights optional equipment and fnishing shown. standard may vary. // benefts - low fuel consumption - optimized system integration ability - high reliability - high availability of power - long maintenance intervals // mtu onsite energy is a single-source supplier // support - global product support offered // standards - engine-generator set is designed and manufactured in facilities certifed to standards iso 2008:9001 and iso 2004:14001 - generator set complies to iso 8528 - generator meets nema mg1, b s5000, iso, din en and ie c standards - nfpa 110 // power rating - system rating: 650 kva - 1700 kva - accepts rated load in one step per nfpa 110 - generator set complies to g3 according to iso 8528-5 - generator set exceeds load steps according to iso 8528-5 // performance assurance certifcation (pac) - engine-generator set tested to iso 8528-5 for transient response - 85% load factor - verifed product design, quality and performance integrity - all engine systems are prototype and factory tested // complete range of accessories available - c ontrol panel - fuel system - fuel connections with shut-off valve mounted to base frame - starting/charging system // emissions - fuel consumption optimized // certifcations - c e certifcation option
2 /// / mtu 12v4000 ds1550 / fc / 60 hz / 380v applic ation data ? // engine manufacturer mtu model 12v4000g43 type 4-cycle arrangement 12v displacement: l 57.2 b ore: mm 170 stroke: mm 210 c ompression ratio 16.4 rated speed: rpm 1800 engine governor adec (ecu 7) max power: k wm 1736 air cleaner dry // fuel system maximum fuel lift: m 5 total fuel fow: l/min 16 // fuel consumption ? l/hr g/kwh at 100% of power rating: 420.4 201 at 75% of power rating: 312.2 199 at 50% of power rating: 221.7 212 // liquid capacity (lubrication) total oil system capacity: l 260 engine jacket water capacity: l 160 intercooler coolant capacity: l 40 // combustion air requirements c ombustion air volume: m 3 /s 2.3 max. air intake restriction: mbar 50 // cooling/radiator system c oolant fow rate (ht circuit): m 3 /h 67 c oolant fow rate (lt circuit): m 3 /h 35 heat rejection to coolant: k w 640 heat radiated to charge air cooling: k w 410 heat radiated to ambient: k w 75 // exhaust system exhaust gas temp. (after turbocharger): c 430 exhaust gas volume: m 3 /s 5.4 maximum allowable back pressure: mbar 85 minimum allowable back pressure: mbar 30 ? all data refers only to the engine and is based on iso standard conditions (25 c and 100m above sea level). ? values referenced are in accordance with iso 3046-1. c onversion calculated with fuel density of 0.83 g/ml. all fuel consumption values refer to rated engine power.
3 /// / mtu 12v4000 ds1550 / fc / 60 hz / 380v // engine 4-c ycle standard single stage air flter oil drain extension & shut-off valve c losed crankcase ventilation governor-electronic isochronous c ommon rail fuel injection fuel consumption optimized engine // generator nema mg1, b s5000, iso, din en and ie c standards self-ventilated superior voltage waveform solid state, volts-per-hertz regulator no load to full load regulation 0.25% voltage regulation no load to full load b rushless alternator with brushless pilot exciter 4 pole, rotating feld sustained short circuit current of up to 300% of the rated current for up to 10 seconds marathon low voltage generator represents standard features ? represents optional features s tandard and o ptional f eatures // system ratings (kw/kva) mtu 12v4000 ds1550 standby power voltage: v 380 phases 3 frequency: hz 60 power output: k w el 1550 power output: kva* 1938 rated amps 2944 generator model marathon 744rsl7091 * cos phi = 0,8 // cooling system jacket water pump thermostat(s) w ater charge air cooling ? jacket water heater
4 /// / mtu 12v4000 ds1550 / fc / 60 hz / 380v // control panel pre-wired control cabinet for easy application of customized controller (v1+) ? island operation (v2) ? automatic mains failure operation with ats (v3a) ? automatic mains failure operation incl. control of generator and mains breaker (v3b) ? island parallel operation of multiple gensets (v4) ? automatic mains failure operation with short (< 10s) mains parallel overlap synchronization (v5) ? mains parallel operation of a single genset (v6) ? mains parallel operation of multiple gensets (v7) ? b asler controller ? deif controller c omplete system metering digital metering engine parameters generator protection functions engine protection sae j1939 engine e cu communications parametrization software multilingual capability multiple programmable contact inputs multiple contact outputs event recording ip 54 front panel rating with integrated gasket ? different expansion modules ? remote annunciator ? daytank control ? generator winding temperature monitoring ? generator bearing temperature monitoring ? differential protection with multi-function protection relay ? modbus rtu-t c p gateway // fuel system flexible fuel connectors mounted to base frame ? fuel filter with water separator ? switchable fuel filter with water separator ? separate fuel cooler represents standard features ? represents optional features s tandard and o ptional f eatures, c ontinuation // exhaust system ? exhaust bellows with connection flange ? y -connection-pipe // mounting system w elded base frame resilient engine and generator mounting modular base frame design // starting/charging system 24v starter ? starter batteries ? b attery rack & cables ? b attery charger
5 /// / mtu 12v4000 ds1550 / fc / 60 hz / 380v subject to change. | 32310221 | edition 01/15 | enc 2015-11. mtu onsite energy a rolls-royce power systems brand www.mtuonsiteenergy.com weights and dimensions sound data // c onsult your local mtu onsite energy distributor for sound data. emissions data // c onsult your local mtu onsite energy distributor for emissions data. r ating definitions and c onditions // standby ratings apply to installations served by a reliable utility source. the standby rating is applicable to varying loads for the duration of a power outage. no overload capability for this rating. ratings are in accordance with iso 8528-1, iso-3046-1, b s 5514 and as 2789. average load factor: 85%. operating hours/year: max. 500. // deration factor: altitude: c onsult your local mtu onsite energy power generation distributor for altitude derations. temperature: c onsult your local mtu onsite energy power generation distributor for temperature derations. rated power is available up to 40 c and 400m above sea level. system dimensions (l x w x h) weight (dry/less tank) open power unit (opu) 4583 x 1836 x 2330 mm 10877 kg materials and specifcations subject to change without notice. w eights and dimensions are based on open power units and are estimates only. c onsult the factory for accurate weights and dimensions for your specifc engine-generator set. drawing above for illustration purposes only, based an standard open power 400 volt engine-generator set. lengths may vary with other voltages. do not use for installation design. see website for unit specifc template drawings.


▲Up To Search▲   

 
Price & Availability of MTU12V4000DS1550

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X