poweralert console launcher to address java runtime environment (jre) issues with respect to the?snmpwebcard?web interface, tripp lite recommends using the poweralert console launcher . this application enables local access of the?snmpwebcard?using a self-contained, compatible jre version. the console launcher can be downloaded for free from the technical support page or from the management solutions / utilities page. 3.2-3.8kw single-phase monitored pdu, 200- 240v outlets (18-c13 & 2-c19), c20/l6-20p, 0u vertical, 35.5 in., taa model number: PDUMNV20HV2 description tripp lite monitored pdu / power distribution unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. poweralert interface supports custom notification of user-specified remote conditions via email, poweralert console launcher, snmp, telnet or ssh interface. pdu output current consumption in amps is displayed via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical it mains breakers trip. features 200/208/230/240v monitored pdu with built-in network interface in 0u 35.5 in. / 90.2cm rackmount form factor; 20a maximum capacity (agency de-rated to 16a) l c20 inlet supports user supplied input cabling; 10ft / 3m l6-20p power cord included l 20 outlets (18 c13 & 2 c19) l 0u 35.5in / 90.2cm vertical rackmount form factor l network interface provides pdu control and data regarding input voltage, frequency and loading information l digital display reports load level information in amps l supports user-specified alarm notification thresholds l in-rack environmental reporting with optional envirosense temperature / humidity sensor and rack access notification with up to 4 optional srswitch door sensors l highlights monitored 16/20a 200-240v pdu; 0u 35.5 in / 90.2cm vertical rackmount l reports voltage, frequency & loading information via ethernet interface l visual current meter; toolless button-mount installation l c20 inlet; 10ft / 3m l6-20p power cable included l 20 outlets (18 c13 & 2 c19); cord retention brackets included l temperature, humidity and contact-closure monitoring options l taa compliant l package includes rackmount pdu l plug retention plates l rack mounting brackets l owner's manual l 1 / 4
specifications dhcp/manual configuration support l 10/100 mbps auto-sensing l real-time clock backup maintains the time of day and date even if the pdu is unpowered l tiered access privileges allow an administrator and a guest to login simultaneously l alert notifications via email or snmp traps offer immediate event notification l firmware upgrade ability supports future product enhancements l supports http, https, poweralert network management system, smtp, snmpv1, snmpv2, snmpv3, telnet, ssh, ftp, dhcp, bootp, ntp protocols l fully compatible with free poweralert network management system / nms software l included cord retention brackets l toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications l compliant with the federal trade agreements act(taa) for gsa schedule purchases l overview upc code 037332162564 pdu type monitored output output capacity details 3.84kw (240v), 3.68kw (230v), 3.52kw (220v), 3.33kw (208v), 3.2kw (200v) / 16a total capacity; 16a max per c19 outlet; 12a (10a ce) max per c13 outlet frequency compatibility 50 / 60 hz output receptacles (18) c13; (2) c19 output nominal voltage 200; 208; 220; 230; 240 overload protection n/a input pdu input voltage 200; 208; 220; 230; 240 recommended electrical service 20a 208/240v; 16a 230v maximum input amps 20 maximum input amps details agency derated to 16a continuous input connection type c20 inlet accepts included l6-20p input cable. alternate c19 input cordsets supported. pdu plug type nema l6-20p; iec-320 c20 input cord length (ft.) 10 input cord length (m) 3.05 2 / 4
? 2019 tripp lite. all rights reserved. all product and company names are trademarks or registered trademarks of their respective holders. use of them does input phase single-phase user interface, alerts & controls front panel lcd display digital meter reports pdu output current in amps, scroll ip-address information; display can be rotated 180 degrees for installation with the input cable at the top front panel leds n/a switches press the scroll ip / rotate button and release after one second to display the configured ip address in 2 digit intervals; press and release after two seconds to rotate the display 180 degrees physical shipping dimensions (hwd / in.) 42.00 x 6.20 x 4.50 shipping dimensions (hwd / cm) 106.68 x 15.75 x 11.43 shipping weight (lbs.) 11.50 shipping weight (kg) 5.22 unit dimensions (hwd / in.) 35.5 x 2.2 x 1.85 unit dimensions (hwd / cm) 90,2 x 5,6 x 4,7 unit weight (lbs.) 6.50 unit weight (kg) 2.95 form factors supported 0u vertical rackmount installation supported with included mounting brackets; supports tooless mounting in button- mount compatible racks pdu form factor vertical (0u) environmental storage temperature range 5 to 122f (-15 to 50c) relative humidity 5-95% non-condensing operating elevation (ft.) 0-10,000 operating elevation (m) 0-3000 communications snmp compatibility pre-installed snmpwebcard provides remote monitoring via poweralert console launcher, telnet, and snmp management systems certifications certifications tested to ul 60950-1 (usa, canada), ce (international), class a (emissions), nom (mexico), rohs compliant, taa compliant warranty product warranty period (worldwide) 2-year limited warranty 3 / 4
not imply any affiliation with or endorsement by them. tripp lite has a policy of continuous improvement. specifications are subject to change without notice. tripp lite uses primary and third-party agencies to test its products for compliance with standards. see a list of tripp lite's testing agencies: https://www.tripplite.com/products/product-certification-agencies 4 / 4
|